Where the penalty points come from

ComponentWhat it coversPoints
Housing codeHPD violations by class, complaints, emergency repairs, litigation, vacate orders, AEP65.2
Structural & safetyDOB violations, ECB/OATH violations by class0
PestsBedbug filings, failed rodent inspections, rodent 311s21.5
DisplacementMarshal evictions executed0
GRADE B

A modest record — below the level that usually signals systemic problems. More recorded distress than 76% of 6-24-unit residential buildings citywide. The citywide median for 6-24-unit residential buildings is 16.3 penalty points per 10 units; this building carries 66.7. In ZIP 10027, 43% of residential buildings hold an A and 14% grade D or F. How grades work

this building
A
B
C

Among 46,798 6-24-unit residential buildings citywide · left is less recorded distress, right is more

Open with the city right now

Open HPD violations1 total — 1 class C (immediately hazardous), 0 class B, 0 class A. Oldest open since 2025-05-02.

status snapshot refreshed weekly from HPD records

Patterns

6 heat or hot-water complaints in the last three years (winter 2025–26: 6).

No bedbug-infested units reported in the last three years of filings.

What 311 hears from this address

59 service requests in the last three years. Most common: UNSANITARY CONDITION (10) · Illegal Parking (8) · Rodent (7) · FLOORING/STAIRS (5) · PLUMBING (4) · GENERAL (3).

Filed construction activity

$492,160 in permitted construction work filed since 2016 (17 filings with a declared cost) — a rough measure of how actively the owner maintains the building. Permit costs cover filed construction work only — they do not capture routine maintenance or repairs done without a permit.

Rent-stabilization signals

YesBuilt before 1974 (1901)
YesSix or more residential units (13)
No421-a / J-51 tax benefit on the current tax roll

2 of 3 signals present. This is the classic profile of a rent-stabilized building (pre-1974, 6+ units) — many units in such buildings remain stabilized. The definitive answer for any unit: request its rent history from NYS Homes & Community Renewal (free, at hcr.ny.gov).

Registered with HPD — the names behind the building

Registered owner(s)HPH Chosen, LLC
Head officerJay Newhouse
Managing agentJay Newhouse
Last registered2025-08-29

as filed by the owner in the building's HPD registration

What the city thinks it's worth

Tax yearCity market valueAssessed value
2025$1,959,000 $881,550
2026$2,083,000 $937,350
2027$1,884,000 $847,800

The city's market estimate has fallen 4% between tax years 2025 and 2027.

Building systems

Heating fuelNATURALGAS

Restaurants in this building

RestaurantCuisineGradeNotes
Zoe CafeEgyptianA—

Report to 311: Food poisoning · Food safety complaint

1 restaurant · 0 with mice evidence · See them on the Mice Map

Flood exposure

Not in the FEMA 1%-annual-chance floodplain (2015 preliminary maps).

Hurricane evacuation zone 6 of 6 — zone 1 evacuates first.

Not in the city's stormwater (cloudburst) flood maps under any modeled scenario.

No street-flooding or sewer-backup complaints on record at this address.

Sources: FEMA flood maps (coastal), NYC DEP Stormwater Flood Maps (cloudburst), NYC hurricane evacuation zones, and 311 records for this address.

Getting around

Subway125 St — A B C D · 1,000 ft straight-line (about a 5-minute walk) · station accessibility: full
BusNearest boarding stop: Frederick Douglass Blvd / W 121 St — M10 · 100 ft
Citi BikeSt Nicholas Ave & Manhattan Ave · 700 ft · station location as of 2026-09-23; live availability
School zones (2024–25 map)Elementary: P.S. 180 Hugo Newman. Confirm with the DOE's school search.

Distances are straight-line, not walking routes. Transit locations from the MTA and Citi Bike, bike facilities from NYC DOT, school zones from the DOE's 2024–25 maps.

Report a problem to 311

301 West 121 Street

Heat or hot waterHeat or hot water
Apartment maintenanceApartment maintenance
Bed bugsBed bugs
Residential pestsResidential pests
Rats or miceRats or mice
Food poisoningFood poisoning
Food safety complaintFood safety complaint
Anything elseAnything else

59 311 service requests from this address in the last three years — 3 of them about heat or hot water.

311 will ask for the address, the apartment if the problem is inside, and what's wrong. Contact details are optional for most complaints; food-poisoning reports can be anonymous. Complaints appear in the city's public 311 data, usually within a day or two, and then in the Live from 311 box on this page.

Sales, deeds & mortgages

Most recent mortgage recorded against this lot: $9,500,000 on 2014-06-06 (lender: Customers Bank), covering 12 lots — the amount covers all of them. Face amount at recording — it may have since been paid down, refinanced or satisfied. View the recorded document.

DateRecordAmountPer res. unit
2020-01-03Mortgage $19,708,905 — from HPH CLAYTON, LLC; HPH MILANO, LLC; HPH TRIO, LLC; HPH 2067, LLC; HPH COURT, LLC; HPH LENOX to NEW YORK COMMUNITY BANK $19,708,905
2020-01-03AL&R $90,800,000 — from HPH CLAYTON, LLC; HPH MILANO, LLC; HPH TRIO, LLC; HPH LENOX, LLC; HPH COURT, LLC; HPH 2067 to NEW YORK COMMUNITY BANK $90,800,000
2020-01-03Agreement $90,800,000 — from HPH TRIO, LLC; HPH CLAYTON, LLC; HPH COURT, LLC; HPH MILANO, LLC; HPH 2067, LLC; HPH LENOX to NEW YORK COMMUNITY BANK $90,800,000
2020-01-03Deed $27,279,494 — from GG MANHATTAN AVE LLC; SOLKAM CHOSEN LLC; SIERRA CAPITAL GROUP LLC; MANHATTAN PORT REALTY L to HPH CHOSEN, LLC $27,279,494
2019-12-20Sold for $27,279,494 $27,279,494 $2,098,423
2017-03-06Agreement $2,603,000 — from ABJ CHOSEN, LLC to CAPITAL ONE MULTIFAMILY FINANCE, LLC $2,603,000
2017-03-06Agreement $9,193,287 — from CAPITAL ONE MULTIFAMILY FINANCE, LLC to ABJ CHOSEN, LLC $9,193,287
2017-03-06Mortgage $2,603,000 — from ABJ CHOSEN, LLC to CAPITAL ONE MULTIFAMILY FINANCE, LLC $2,603,000
2014-06-06Deed $14,500,000 — from 510 MANHATTAN AFFORDABLE HOUSING L.P. to ABJ CHOSEN, LLC $14,500,000
2014-06-06Mortgage $9,500,000 — from ABJ CHOSEN, LLC to CUSTOMERS BANK $9,500,000
2014-06-06AL&R $9,500,000 — from ABJ CHOSEN, LLC to CUSTOMERS BANK $9,500,000
2013-01-15RPTT&RET $4,868,251 — from CITY AFFORDABLE HOUSING LLC to 510 MANHATTAN AVENUE II LLC $4,868,251
2012-08-21RPTT $5,056,091 — from UNISON HOLDINGS, LLC to AMERICAN TOWERS LLC $5,056,091
2012-05-07RPTT&RET $5,056,091 — from UNISON SITE MANAGEMENT II, L.L.C. to AMERICAN TOWERS LLC $5,056,091
2011-09-21EASE $321,570 — from 510 MANHATTAN AFFORDABLE HOUSING, LP to T8 UNISON SITE MANAGEMENT, LLC $321,570

Ten-year activity

1,0005000
2017
2018
2019
2020
2021
739
2022
2023
2024
2025
2026
ConstructionEnforcementHousing & tenantsOwnership & moneyHealth & systems
Show as table
YearConstructionEnforcementHousing & tenantsOwnership & moneyHealth & systemsTotal
201741607173
20180113103135
201903803692
20201010953118
20215657105587
20226372703739
20230260206610
202400100515
202550660879
202621280536
This record is free. Keeping it free costs money.
Servers, data pipelines, weekends. Pay what you want — a dollar helps.
Chip in

The last 12 months — 48 records

DateRecord
2026-08-25DOB complaint, category ?
2026-07-22311: UNSANITARY CONDITION — MOLD
2026-07-22Tenant complaint: UNSANITARY CONDITION — MOLD
2026-07-12311: Illegal Parking — Blocked Bike Lane
2026-06-22Permit Antenna — Permit Issued
2026-06-22Permit Antenna — Signed-off
2026-06-11Rodent inspection: Passed
2026-05-07HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ. FT. AT 1ST CLOSET FROM NORTH AT EAST,
2026-05-07HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM
2026-05-07HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 1A, 1st
2026-05-07HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FR
2026-05-07HPD class B: § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVI
2026-05-07HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2026-05-05Boiler inspection
2026-05-05Boiler inspection
2026-04-29311: PLUMBING — BATHTUB/SHOWER
2026-04-29311: FLOORING/STAIRS — FLOOR
2026-04-29311: UNSANITARY CONDITION — MOLD
2026-04-29311: UNSANITARY CONDITION — PESTS
2026-04-29311: UNSANITARY CONDITION — PESTS
2026-04-29Tenant complaint: PLUMBING — BATHTUB/SHOWER
2026-04-29Tenant complaint: FLOORING/STAIRS — FLOOR
2026-04-29Tenant complaint: UNSANITARY CONDITION — PESTS
2026-04-29Tenant complaint: UNSANITARY CONDITION — PESTS
2026-04-29Tenant complaint: UNSANITARY CONDITION — MOLD
2026-04-27Restaurant inspection: ZOE CAFE — grade A
2026-03-26311: Water System — Hydrant Leaking (WC1)
2026-03-08311: Noise - Residential — Loud Music/Party
2026-03-08311: Noise - Residential — Loud Music/Party
2026-03-07311: Noise - Residential — Loud Music/Party
2026-02-17311: Non-Emergency Police Matter — Trespassing
2026-01-30311: HEAT/HOT WATER — APARTMENT ONLY
2026-01-30311: UNSANITARY CONDITION — PESTS
2026-01-30Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-01-30Tenant complaint: UNSANITARY CONDITION — PESTS
2026-01-12Rodent inspection: Failed for Rat Activity
2025-12-30311: Street Condition — Blocked - Construction
2025-12-10Rodent inspection: Failed for Rat Activity
2025-12-08Bedbug filing: 0 infested units
2025-12-05311: HEAT/HOT WATER — ENTIRE BUILDING
2025-12-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2025-11-26311: Rodent — Rat Sighting
2025-11-26311: Rodent — Condition Attracting Rodents
2025-11-15311: Rodent — Condition Attracting Rodents
2025-11-13311: Rodent — Rat Sighting
2025-11-13311: HEAT/HOT WATER — ENTIRE BUILDING
2025-11-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2025-10-23Rodent inspection: Failed for Rat Activity

The full timeline

showing the 2,000 most recent of 2,840 events

2026
2026-08-25DOB complaint, category ?
2026-07-22311: UNSANITARY CONDITION — MOLD
2026-07-22Tenant complaint: UNSANITARY CONDITION — MOLD
2026-07-12311: Illegal Parking — Blocked Bike Lane
2026-06-22Permit Antenna — Permit Issued
2026-06-22Permit Antenna — Signed-off
2026-06-11Rodent inspection: Passed
2026-05-07HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ. FT. AT 1ST CLOSET FROM NORTH AT EAST,
2026-05-07HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM
2026-05-07HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 1A, 1st
2026-05-07HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FR
2026-05-07HPD class B: § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVI
2026-05-07HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2026-05-05Boiler inspection
2026-05-05Boiler inspection
2026-04-29311: PLUMBING — BATHTUB/SHOWER
2026-04-29311: FLOORING/STAIRS — FLOOR
2026-04-29311: UNSANITARY CONDITION — MOLD
2026-04-29311: UNSANITARY CONDITION — PESTS
2026-04-29311: UNSANITARY CONDITION — PESTS
2026-04-29Tenant complaint: PLUMBING — BATHTUB/SHOWER
2026-04-29Tenant complaint: FLOORING/STAIRS — FLOOR
2026-04-29Tenant complaint: UNSANITARY CONDITION — PESTS
2026-04-29Tenant complaint: UNSANITARY CONDITION — PESTS
2026-04-29Tenant complaint: UNSANITARY CONDITION — MOLD
2026-04-27Restaurant inspection: ZOE CAFE — grade A
2026-03-26311: Water System — Hydrant Leaking (WC1)
2026-03-08311: Noise - Residential — Loud Music/Party
2026-03-08311: Noise - Residential — Loud Music/Party
2026-03-07311: Noise - Residential — Loud Music/Party
2026-02-17311: Non-Emergency Police Matter — Trespassing
2026-01-30311: HEAT/HOT WATER — APARTMENT ONLY
2026-01-30311: UNSANITARY CONDITION — PESTS
2026-01-30Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-01-30Tenant complaint: UNSANITARY CONDITION — PESTS
2026-01-12Rodent inspection: Failed for Rat Activity
2025
2025-12-30311: Street Condition — Blocked - Construction
2025-12-10Rodent inspection: Failed for Rat Activity
2025-12-08Bedbug filing: 0 infested units
2025-12-05311: HEAT/HOT WATER — ENTIRE BUILDING
2025-12-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2025-11-26311: Rodent — Rat Sighting
2025-11-26311: Rodent — Condition Attracting Rodents
2025-11-15311: Rodent — Condition Attracting Rodents
2025-11-13311: Rodent — Rat Sighting
2025-11-13311: HEAT/HOT WATER — ENTIRE BUILDING
2025-11-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2025-10-23Rodent inspection: Failed for Rat Activity
2025-10-17HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MABLE SADDLE AT FLOOR IN THE BATHROOM LOCATED AT APT 1A, 1s
2025-10-17HPD class C: 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND A
2025-10-17HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHROOM LOCATED AT APT 1
2025-10-17HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD BASE CABINET AT WEST WALL AND EAST IN THE KITCHEN LOCATED AT APT 1A,
2025-10-09311: GENERAL — CABINET
2025-10-09311: UNSANITARY CONDITION — MOLD
2025-10-09311: UNSANITARY CONDITION — PESTS
2025-10-09311: FLOORING/STAIRS — FLOOR
2025-10-09311: UNSANITARY CONDITION — PESTS
2025-10-09311: FLOORING/STAIRS — FLOOR
2025-10-09311: PLUMBING — BASIN/SINK
2025-10-09Tenant complaint: GENERAL — CABINET
2025-10-09Tenant complaint: UNSANITARY CONDITION — PESTS
2025-10-09Tenant complaint: UNSANITARY CONDITION — MOLD
2025-10-09Tenant complaint: UNSANITARY CONDITION — PESTS
2025-10-09Tenant complaint: FLOORING/STAIRS — FLOOR
2025-10-09Tenant complaint: FLOORING/STAIRS — FLOOR
2025-10-09Tenant complaint: PLUMBING — BASIN/SINK
2025-09-18Air permit (REGISTRATION), fuel: NATURALGAS
2025-08-22311: Rodent — Rat Sighting
2025-07-29311: Rodent — Rat Sighting
2025-07-22311: APPLIANCE — REFRIGERATOR
2025-07-22311: APPLIANCE — ELECTRIC/GAS RANGE
2025-07-22311: FLOORING/STAIRS — FLOOR
2025-07-22311: PAINT/PLASTER — WALL
2025-07-22311: UNSANITARY CONDITION — PESTS
2025-07-22311: FLOORING/STAIRS — FLOOR
2025-07-22311: PLUMBING — BASIN/SINK
2025-07-22311: GENERAL — CABINET
2025-07-22Tenant complaint: FLOORING/STAIRS — FLOOR
2025-07-22Tenant complaint: UNSANITARY CONDITION — PESTS
2025-07-22Tenant complaint: FLOORING/STAIRS — FLOOR
2025-07-22Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2025-07-22Tenant complaint: PAINT/PLASTER — WALL
2025-07-22Tenant complaint: APPLIANCE — REFRIGERATOR
2025-07-22Tenant complaint: PLUMBING — BASIN/SINK
2025-07-22Tenant complaint: GENERAL — CABINET
2025-07-11Rodent inspection: Failed for Rat Activity
2025-07-08Permit Antenna — Permit Issued
2025-07-08Permit Antenna — Signed-off
2025-06-24Permit Antenna — Signed-off
2025-06-24Permit Antenna — Permit Issued
2025-06-13311: Illegal Parking — Double Parked Blocking Traffic
2025-06-09Rodent inspection: Failed for Rat Activity
2025-05-15Job filed: Decommission of T-MOBILE site on the roof. No change in use, egress or occupancy.$50,000
2025-05-08311: Homeless Person Assistance — Chronic
2025-05-02HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM
2025-05-02HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET DRAWER AT EAST WALL IN THE KITCHEN LOCATED AT APT 1A, 1st STO
2025-04-28311: APPLIANCE — ELECTRIC/GAS RANGE
2025-04-28311: PLUMBING — BASIN/SINK
2025-04-28311: UNSANITARY CONDITION — PESTS
2025-04-28311: DOOR/WINDOW — DOOR
2025-04-28311: GENERAL — CABINET
2025-04-28311: PAINT/PLASTER — WALL
2025-04-28311: Rodent — Rat Sighting
2025-04-28Tenant complaint: GENERAL — CABINET
2025-04-28Tenant complaint: DOOR/WINDOW — DOOR
2025-04-28Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2025-04-28Tenant complaint: UNSANITARY CONDITION — PESTS
2025-04-28Tenant complaint: PLUMBING — BASIN/SINK
2025-04-28Tenant complaint: PAINT/PLASTER — WALL
2025-03-27Boiler inspection
2025-03-27Boiler inspection
2025-01-23Rodent inspection: Passed
2025-01-12311: Illegal Parking — Blocked Bike Lane
2025-01-11311: Illegal Parking — Blocked Bike Lane
2025-01-05311: Illegal Parking — Blocked Bike Lane
2024
2024-12-29311: Dirty Condition — Trash
2024-12-17Bedbug filing: 0 infested units
2024-12-06Rodent inspection: Failed for Rat Activity
2024-07-05311: Illegal Parking — Double Parked Blocking Vehicle
2024-06-25Boiler inspection
2024-06-25Boiler inspection
2024-06-06Rodent inspection: Passed
2024-04-23311: New Tree Request — For One Address
2024-04-23311: New Tree Request — For One Address
2024-04-17Restaurant inspection: ZOE CAFE — grade A
2024-04-02Bedbug filing: 0 infested units
2024-04-01HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2024-03-21311: Illegal Parking — Blocked Crosswalk
2024-03-21311: Illegal Parking — Blocked Crosswalk
2024-02-01311: For Hire Vehicle Complaint — Driver Complaint - Non Passenger
2023
2023-12-27311: For Hire Vehicle Complaint — Driver Complaint - Non Passenger
2023-12-04Rodent inspection: Passed
2023-11-28311: Illegal Dumping — Removal Request
2023-11-27Bedbug filing: 0 infested units
2023-10-05311: Illegal Parking — Double Parked Blocking Vehicle
2023-09-20311: Noise - Vehicle — Engine Idling
2023-09-05Boiler inspection
2023-09-05Boiler inspection
2023-07-23311: Water System — Hydrant Running (WC3)
2023-07-14Rodent inspection: Passed
2023-06-13Rodent inspection: Failed for Other Reason
2023-04-19311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-18311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-11311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-08311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-08311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-08311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-05311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-05311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-04311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-04311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-04311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-04-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-31311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-31311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-31311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-31311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-30311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-30311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-30311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-29311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-29311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-27311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-24311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-22311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-22HPD class B: § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF A FUTON
2023-03-21311: DOOR/WINDOW — DOOR
2023-03-21311: DOOR/WINDOW — DOOR
2023-03-21311: UNSANITARY CONDITION — PESTS
2023-03-21311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-21311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-21Tenant complaint: UNSANITARY CONDITION — PESTS
2023-03-21Tenant complaint: DOOR/WINDOW — DOOR
2023-03-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-21Tenant complaint: DOOR/WINDOW — DOOR
2023-03-20311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-20311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-20311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-20311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-20311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-19311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-19311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-18311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-16311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-14311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-14311: HEAT/HOT WATER — APARTMENT ONLY
2023-03-14311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-14311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-14Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-03-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-13311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-13HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT LOWER WINDOW SASH AT SECOND WINDOW FROM EAST AT SOUTH IN THE 1st ROOM F
2023-03-12311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-12311: HEAT/HOT WATER — APARTMENT ONLY
2023-03-12311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-12311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-12Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-03-11311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-11311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-11311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-08311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-05311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-05311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-05311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-03FDNY inspection (RISK)
2023-03-03FDNY inspection (COM_OCPCY)
2023-03-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-03-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-27311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-27311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-27311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-26311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-26311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-26311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-26311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-26311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-26311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-26Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-25311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-25311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-25Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-25Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-24311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-24311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-24311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-24311: UNSANITARY CONDITION — MOLD
2023-02-24311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-24311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-24Tenant complaint: UNSANITARY CONDITION — MOLD
2023-02-24Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-23311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-23311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-23311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-22311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-22311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-22311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-22311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-22Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-21311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-21311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-20311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-19311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-19311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-19311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-19311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-18311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-17311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-14311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-12311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-06Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-06Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-05311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-05311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-05311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-04311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-04311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-04311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-04311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-04311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-04Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-02311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-02311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-02311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01311: HEAT/HOT WATER — APARTMENT ONLY
2023-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-01Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-30311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-30311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-30311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-29311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-28311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-27311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-27311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-27311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-24311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-24311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-24311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-23311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-23311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-23311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-23311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-23311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-22311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-22311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-22311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-22311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-20311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-20311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-20311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-20311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-19311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-18311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-18311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-18311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-17311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-17311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-17311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-16311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-16311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-16311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-15311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-12311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-11HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 1 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 2C, 2
2023-01-11HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 1 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 2C, 2
2023-01-10311: HEAT/HOT WATER — APARTMENT ONLY
2023-01-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-10311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-10Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2023-01-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-07311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-05311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-05311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-04Rodent inspection: Passed
2023-01-04311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-04311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-03311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-02311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-01-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022
2022-12-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-29311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-29Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-12-29Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-12-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-28Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-12-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-25311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-25311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-25311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24311: Rodent — Rat Sighting
2022-12-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-22311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-22311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-19311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-19311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-16311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-16311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-13311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-07311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-07311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-06311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-06311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-06311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-05311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-05311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-05311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-05311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-02Bedbug filing: 0 infested units
2022-12-02311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-02311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-02311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-01311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-01311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-01311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-01311: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-12-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-30311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-30311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-30311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-16311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-14HPD class B: § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS ON 3RD
2022-11-13311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-13311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-13311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-31311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-23311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-19311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-03311: UNSANITARY CONDITION — GARBAGE/RECYCLING STORAGE
2022-10-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-10-03Tenant complaint: UNSANITARY CONDITION — GARBAGE/RECYCLING STORAGE
2022-09-07Job filed: PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33 OF THE 20$9,000
2022-09-07Permit Sidewalk Shed — Signed-off
2022-08-25DOB violation C: THE DOB HEREBY ORDERS YOU TO STOP ALL WORK UNDER JOB # M00660021 - EXCEPT TO MAKE SITE SAFE - DUE TO SPECIAL INSPECTOR ALBERTO
2022-08-25DOB violation C: THE DOB HEREBY ORDERS YOU TO STOP ALL WORK UNDER JOB # M00660021 - EXCEPT TO MAKE SITE SAFE - DUE TO SPECIAL INSPECTOR ALBERTO
2022-08-22DOB complaint, category ?
2022-08-15Boiler inspection
2022-08-15Boiler inspection
2022-06-08Permit General Construction — Signed-off
2022-05-21311: Noise - Street/Sidewalk — Loud Talking
2022-05-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-05-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-05-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-05-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-05-09Rodent inspection: Passed
2022-05-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-05-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-05-07311: HEAT/HOT WATER — ENTIRE BUILDING
2022-05-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-05-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-05-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-29311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-25311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-19311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-19311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-19311: HEAT/HOT WATER — APARTMENT ONLY
2022-04-19311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-19Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-04-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-07311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-05311: HEAT/HOT WATER — ENTIRE BUILDING
2022-04-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-30311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-29311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-29311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-23311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-23HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM
2022-03-23HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2C , 2nd STORY, 1st APARTMENT FROM EAS
2022-03-22311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-16Job filed: Install new boilers in existing cellar$20,000
2022-03-16Job filed: New water heaters in existing cellar$4,500
2022-03-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-14Job filed: Facade Repairs as per Plan$31,700
2022-03-13311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-13311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-12311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-10HPD litigation: Heat and Hot Water
2022-03-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-04311: Graffiti — Police Report Not Requested
2022-03-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-02311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-01311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-01311: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-03-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-25311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-25311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-25311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-23311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-23311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2022-02-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-19311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-19311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-19311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-16Bedbug filing: 0 infested units
2022-02-16311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2022-02-16311: Graffiti — Graffiti
2022-02-16311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-16HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2022-02-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-15311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2022-02-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-14HPD class A: § 27-2005 ADM CODE REFIT UPPER WINDOW SASH IN THE 3rd ROOM FROM EAST LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
2022-02-13311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-07311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-07311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-06311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-06311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-05311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-05311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-02311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-31311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-31311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-30311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-30311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-28311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-27311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-26311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-26HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER TEMPERATURE EXCEEDS 130 DEGREES AT SINK IN THE KITCHEN LOCATED A
2022-01-26HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM
2022-01-26HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM
2022-01-26HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT
2022-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-24311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-23311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-22311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-21311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-20311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-19311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-17311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-16311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-16311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-15HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD ENTRANCE DOOR IN THE BATHROOM LOCATED AT APT 2C, 2nd S
2022-01-15HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE AT UPPER AND LOWER WINDOW SASH IN THE BATHROOM LOCATED AT APT 2C,
2022-01-15HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... EVIDENCE OF MOLD AT CEILING (APPROX 3 SQ.FT) NORTH WALL
2022-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-01-14Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-13311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-13311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-13Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-01-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-10311: UNSANITARY CONDITION — MOLD
2022-01-10311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-10311: DOOR/WINDOW — WINDOW FRAME
2022-01-10311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-10Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2022-01-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-10Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-01-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-10Tenant complaint: UNSANITARY CONDITION — MOLD
2022-01-10Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-07311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-07311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-07311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-07Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-01-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-04311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-04311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-04311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-04Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-01-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-04Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-01-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-01-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-03HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM GATE TO CELLAR LOCKED AT 1ST STORY
2022-01-03HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT
2022-01-02311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-02311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021
2021-12-31Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-12-30311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-29311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-29311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-29311: HEAT/HOT WATER — APARTMENT ONLY
2021-12-29311: HEAT/HOT WATER — APARTMENT ONLY
2021-12-29311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-29311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-29311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-29311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-29311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-29Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-12-28311: HEAT/HOT WATER — APARTMENT ONLY
2021-12-28311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-28311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-28Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-12-27311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-27311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-12-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-12-26311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-26311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-23311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-23311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-23311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-23HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GASKET SEAL AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1s
2021-12-23HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BASEMENT DOOR LOCKED AT BOILER ROOM
2021-12-23HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT LOWER WINDOW SASH IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1s
2021-12-23HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORT
2021-12-23HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT
2021-12-22311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-22311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-22311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-22311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-22311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-21311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-21311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-21311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-21311: HEAT/HOT WATER — APARTMENT ONLY
2021-12-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-21Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-12-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-21HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1A , 1st STORY, 1
2021-12-21HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BASEMENT DOOR LOCKED AT BOILER ROOM
2021-12-21HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1A , 1st STORY, 1st APARTMENT
2021-12-21HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1A , 1st STORY, 1st APARTMENT FROM
2021-12-21HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1A , 1st STORY, 1st APARTMENT FROM SO
2021-12-20FDNY inspection (RISK)
2021-12-20311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-20311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-20311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-19311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-19311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-19311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18311: DOOR/WINDOW — WINDOW PANE
2021-12-18311: APPLIANCE — REFRIGERATOR
2021-12-18311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18Tenant complaint: APPLIANCE — REFRIGERATOR
2021-12-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-18Tenant complaint: DOOR/WINDOW — WINDOW PANE
2021-12-17311: Vaccine Mandate Non-Compliance — Customer Proof of Vaccination Not Checked
2021-12-15311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-10311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-08311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-06311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-06311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-05311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-05311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-04HPD class C: § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO H
2021-12-03311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-03311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-03311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-03311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-03311: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-30311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-30311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-30311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-29311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-29311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-29Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-29HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
2021-11-29HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM AT BUILDING FRONT AREAWAY AT BOILER ROOM
2021-11-28311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-28Permit Boiler Equipment — Signed-off
2021-11-27311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-26311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-26311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-26Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-26Permit Plumbing — Signed-off
2021-11-24311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-24311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-24311: UNSANITARY CONDITION — MOLD
2021-11-24311: DOOR/WINDOW — WINDOW FRAME
2021-11-24311: DOOR/WINDOW — DOOR
2021-11-24Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2021-11-24Tenant complaint: UNSANITARY CONDITION — MOLD
2021-11-24Tenant complaint: DOOR/WINDOW — DOOR
2021-11-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-23311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-23311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-23311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-23311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-23311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-23311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-23Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-22311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-22311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-19311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-19311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-19Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-17311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-17311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-17Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-15311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-15311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-15Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-15HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING 1 SQ FT IN THE BATHROOM LOCATED AT APT 2C, 2
2021-11-15HPD class C: § 27-2005, 2007, 204.1 HMC CODE: ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE ENTRANCE LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NO
2021-11-15HPD class C: § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CI
2021-11-14311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-14311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-13311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-13Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-06311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-06Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-05311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-05311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-05311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-05311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-05311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-05Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-04311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-04311: Illegal Parking — Blocked Sidewalk
2021-11-04311: DOOR/WINDOW — WINDOW FRAME
2021-11-04311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-04311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-04Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-04Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-04Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2021-11-04Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-03311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-03311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-03311: General Construction/Plumbing — Building Shaking/Vibrating/Structural Stability
2021-11-03311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-03311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-03DOB complaint, category ?
2021-11-02311: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-11-01311: General Construction/Plumbing — Building Shaking/Vibrating/Structural Stability
2021-11-01DOB complaint, category ?
2021-11-01ECB CLASS - 2 violation: AT TIME OF INSPECTION OBSERVED SEVERAL MINOR VERTICAL CRACKS ON FRONT BRICK FACADE BETWEEN STREET LEVEL HANDICAP RAMP & 2ND FLOOR $625
2021-10-29311: HEAT/HOT WATER — APARTMENT ONLY
2021-10-29Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-10-28311: HEAT/HOT WATER — ENTIRE BUILDING
2021-10-28311: HEAT/HOT WATER — APARTMENT ONLY
2021-10-28Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-10-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-10-25Rodent inspection: Passed
2021-10-25311: General Construction/Plumbing — Building Shaking/Vibrating/Structural Stability
2021-10-25DOB complaint, category ?
2021-10-24311: HEAT/HOT WATER — ENTIRE BUILDING
2021-10-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-10-19311: HEAT/HOT WATER — APARTMENT ONLY
2021-10-19Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-10-14311: UNSANITARY CONDITION — GARBAGE/RECYCLING STORAGE
2021-10-14Tenant complaint: UNSANITARY CONDITION — GARBAGE/RECYCLING STORAGE
2021-10-12Job filed: Plumbing for new boilers (2) and water heaters (2) in cellar$4,500
2021-10-12Job filed: Install new boilers (2) in cellar$20,000
2021-10-10311: Dirty Condition — Trash
2021-09-23311: Rodent — Signs of Rodents
2021-09-16HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL IN THE KITCHEN LOCATED AT APT 2C, 2nd STO
2021-09-16HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 10 SQ.FT.AT CEILING IN THE BATHROOM LOCATED AT A
2021-09-16HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS AND CEILING IN THE BATHROOM L
2021-09-16HPD class B: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE COUNTER TOP AT SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FRO
2021-09-15HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 4A, 4th STOR
2021-09-15HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 4
2021-09-07311: GENERAL — CABINET
2021-09-07311: PAINT/PLASTER — WALL
2021-09-07311: UNSANITARY CONDITION — MOLD
2021-09-07311: DOOR/WINDOW — WINDOW FRAME
2021-09-07Tenant complaint: GENERAL — CABINET
2021-09-07Tenant complaint: PAINT/PLASTER — WALL
2021-09-07Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2021-09-07Tenant complaint: UNSANITARY CONDITION — MOLD
2021-09-01311: WATER LEAK — HEAVY FLOW
2021-09-01Tenant complaint: WATER LEAK — HEAVY FLOW
2021-07-15311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2021-07-06311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2021-06-28311: General Construction/Plumbing — Building Shaking/Vibrating/Structural Stability
2021-06-28311: GENERAL — SIGNAGE MISSING
2021-06-28311: SAFETY — FIRE ESCAPE
2021-06-28Tenant complaint: GENERAL — SIGNAGE MISSING
2021-06-28Tenant complaint: SAFETY — FIRE ESCAPE
2021-06-28DOB complaint, category ?
2021-05-30311: HEAT/HOT WATER — ENTIRE BUILDING
2021-05-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-05-12311: HEAT/HOT WATER — ENTIRE BUILDING
2021-05-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-05-10311: HEAT/HOT WATER — ENTIRE BUILDING
2021-05-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-27311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-26311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-25311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-23311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-22311: HEAT/HOT WATER — APARTMENT ONLY
2021-04-22311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-22Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-04-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-21Rodent inspection: Passed
2021-04-21311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-18311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-16311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-16311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-16311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-15311: Rodent — Rat Sighting
2021-04-15311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-14311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-12311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-12311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-02311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-02311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-01311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-01311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-01311: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-04-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-30311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-29311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-29311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-28311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-24311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-23311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-22311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-21311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-20311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-20311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-20Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-19311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-19311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-18311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-17311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-17311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-17Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-15311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-15311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-15Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-15Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-13311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-13311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-13Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-13Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-12Rodent inspection: Passed
2021-03-12311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-12Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-10311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-10Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-08311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-08311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-08Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-07311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-07311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-06311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-06311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-06311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-06Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-05311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-05311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-05311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-04311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-04311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-04311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-04Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-04Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-04Job filed: New water heaters in existing cellar$4,500
2021-03-03311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-03311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-03311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-03311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-03311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-03311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-02311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-02311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-02311: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-02311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-03-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-03-01311: HEAT/HOT WATER — APARTMENT ONLY
2021-03-01Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-28311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-28311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-28Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-28Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-26311: Rodent — Rat Sighting
2021-02-26311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-26311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-26311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-26311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-26Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-26Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-26Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-26Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-25311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-25Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-24311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-24Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-23311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-23Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-22311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-22311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-22Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-22Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-21311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-21Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-20311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-20Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-19311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-19311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-19Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-19Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-18311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-18Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-18HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM
2021-02-17311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-17Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-16Bedbug filing: 0 infested units
2021-02-16311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-16Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-15311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-15Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-14311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-14Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-13311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-13Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-12311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-12311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-12311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-12Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-12Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-12Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-11311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-11311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-11311: HEAT/HOT WATER — ENTIRE BUILDING
2021-02-11311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-11311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-11Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-11Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-11Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-02-11Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-10Rodent inspection: Failed for Rat Activity
2021-02-10311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-10311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-10Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-10Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-08311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-08Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-07311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-07Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-06311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-06Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-02-05311: HEAT/HOT WATER — APARTMENT ONLY
2021-02-05Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY

Support this site Back to the building page