Building Biography

The MapLandlordsNeighborhoodsZIP CodesGradesThe Mice MapAboutWhat's new

Building report

304 West 120 Street · Manhattan · BBL 1019460038 · generated 2026-10-20 · FREE

Free while in beta — every NYC building gets a report like this, updated weekly from city records. If it's useful, chip in to keep it free

Where the penalty points come from

ComponentWhat it coversPoints
Housing codeHPD violations by class, complaints, emergency repairs, litigation, vacate orders, AEP168.6
Structural & safetyDOB violations, ECB/OATH violations by class4
PestsBedbug filings, failed rodent inspections, rodent 311s36.5
DisplacementMarshal evictions executed0
GRADE C

A meaningful record of code violations or complaints relative to its peers. More recorded distress than 92% of 6-24-unit residential buildings citywide. The citywide median for 6-24-unit residential buildings is 16.3 penalty points per 10 units; this building carries 232.3. In ZIP 10027, 43% of residential buildings hold an A and 14% grade D or F. How grades work

this building
A
B
C

Among 46,798 6-24-unit residential buildings citywide · left is less recorded distress, right is more

Open with the city right now

Open HPD violations52 total — 12 class C (immediately hazardous), 27 class B, 13 class A. Oldest open since 2012-08-31.

status snapshot refreshed weekly from HPD records

Patterns

29 heat or hot-water complaints in the last three years (winter 2024–25: 10 · winter 2025–26: 19). Repeated winter clusters suggest a chronic heating problem.

10
’24–25
19
’25–26

No bedbug-infested units reported in the last three years of filings.

What 311 hears from this address

76 service requests in the last three years. Most common: Rodent (19) · HEAT/HOT WATER (13) · UNSANITARY CONDITION (9) · PAINT/PLASTER (6) · GENERAL (5) · ELECTRIC (4).

Filed construction activity

$36,000 in permitted construction work filed since 2016 (1 filings with a declared cost) — a rough measure of how actively the owner maintains the building. Permit costs cover filed construction work only — they do not capture routine maintenance or repairs done without a permit.

Rent-stabilization signals

YesBuilt before 1974 (1901)
YesSix or more residential units (9)
No421-a / J-51 tax benefit on the current tax roll

2 of 3 signals present. This is the classic profile of a rent-stabilized building (pre-1974, 6+ units) — many units in such buildings remain stabilized. The definitive answer for any unit: request its rent history from NYS Homes & Community Renewal (free, at hcr.ny.gov).

Registered with HPD — the names behind the building

Registered owner(s)GARDEN OF EDEN ASSOCIATES LP
Head officerMALCOLM A PUNTER
Managing agentEDEN EQUITABLE MANAGEMENT CORPORATION
Last registered2025-11-17

as filed by the owner in the building's HPD registration

What the city thinks it's worth

Tax yearCity market valueAssessed value
2025$1,567,200 $705,240
2026$1,425,000 $641,250
2027$1,652,000 $743,400

The city's market estimate has risen 5% between tax years 2025 and 2027.

Tax exemptions on the roll: 420C

Building systems

Heating fuelNO2FUEL

Flood exposure

Not in the FEMA 1%-annual-chance floodplain (2015 preliminary maps).

Not in a hurricane evacuation zone.

Not in the city's stormwater (cloudburst) flood maps under any modeled scenario.

No street-flooding or sewer-backup complaints on record at this address.

Sources: FEMA flood maps (coastal), NYC DEP Stormwater Flood Maps (cloudburst), NYC hurricane evacuation zones, and 311 records for this address.

Getting around

Subway116 St — B C · 950 ft straight-line (about a 5-minute walk) · station accessibility: none
125 St — A B C D · 0.3 mi straight-line (about a 7-minute walk) · station accessibility: full
BusNearest boarding stop: Frederick Douglass Blvd / W 119 St — M10 · 250 ft
Citi BikeFrederick Douglass Blvd & W 117 St · 700 ft · station location as of 2026-09-23; live availability
School zones (2024–25 map)Elementary: P.S. 180 Hugo Newman. Confirm with the DOE's school search.

Distances are straight-line, not walking routes. Transit locations from the MTA and Citi Bike, bike facilities from NYC DOT, school zones from the DOE's 2024–25 maps.

Report a problem to 311

304 West 120 Street

Heat or hot waterHeat or hot water
Apartment maintenanceApartment maintenance
Bed bugsBed bugs
Residential pestsResidential pests
Rats or miceRats or mice
Anything elseAnything else

76 311 service requests from this address in the last three years — 13 of them about heat or hot water.

311 will ask for the address, the apartment if the problem is inside, and what's wrong. Contact details are optional for most complaints; food-poisoning reports can be anonymous. Complaints appear in the city's public 311 data, usually within a day or two, and then in the Live from 311 box on this page.

The landlord's report card

Managed by EDEN EQUITABLE MANAGEMENT CORPORATION — 6 buildings, 119 units. Grades across the portfolio: A1 · C4 · D1. See the whole portfolio

BuildingBoroughUnitsGrade
2211 8 Avenue MN76 C
361 West 116 Street MN11 D
135 West 119 Street MN10 A
304 West 120 Street MN9 C
360 West 117 Street MN9 C
46 West 120 Street MN4 C

Sales, deeds & mortgages

Most recent mortgage recorded against this lot: $300,000 on 2003-12-22 (lender: The City Of New York), covering 3 lots — the amount covers all of them. Face amount at recording — it may have since been paid down, refinanced or satisfied. View the recorded document.

DateRecordAmountPer res. unit
2003-12-22Mortgage $300,000 — from GARDEN OF EDEN ASSOCIATES, L.P. to THE CITY OF NEW YORK $300,000
2003-12-22Agreement $8,507,581 — from GARDEN OF EDEN ASSOCIATES, L.P.; THE CITY OF NEW YORK to THE CITY OF NEW YORK; GARDEN OF EDEN ASSOCIATES, L.P. $8,507,581
2002-09-24Mortgage $8,207,581 — from GARDEN OF EDEN ASSOCIATES, L.P. to NYC HPD $8,207,581

Ten-year activity

100500
2017
2018
2019
2020
2021
2022
2023
80
2024
2025
2026
ConstructionEnforcementHousing & tenantsOwnership & moneyHealth & systems
Show as table
YearConstructionEnforcementHousing & tenantsOwnership & moneyHealth & systemsTotal
20174070415
2018006028
20192150614
2020003115
202100150116
202200230528
202300511355
202422710580
202502490960
202600400545
This record is free. Keeping it free costs money.
Servers, data pipelines, weekends. Pay what you want — a dollar helps.
Chip in

The last 12 months — 51 records

DateRecord
2026-10-08311: Illegal Tree Damage — Roots Damaged
2026-09-17Rodent inspection: Failed for Rat Activity
2026-08-21311: PLUMBING — WATER SUPPLY
2026-08-21Tenant complaint: PLUMBING — WATER SUPPLY
2026-08-20Rodent inspection: Failed for Rat Activity and Other Reason
2026-07-23311: Rodent — Rat Sighting
2026-06-15Rodent inspection: Passed
2026-04-29HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2026-03-20Boiler inspection
2026-03-20Boiler inspection
2026-02-27City emergency repair (OMO): install new self closing hinges to apt 3a, entrance door nyc hpd emergency operations division- ''essentials service wor
2026-02-11HPD class A: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2026-02-11HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASHBASIN AND BATHTUB IN THE BATHROOM LOCATED AT APT 3A, 3rd ST
2026-02-11HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BASEMENT AT BOILER ROOM
2026-02-11HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASHBASIN AND BATHTUB IN THE BATHROOM LOCATED AT APT 3A, 3rd STO
2026-02-11HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-02-11HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2026-02-11HPD class B: § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVI
2026-02-11HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2026-02-11HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST
2026-02-09311: HEAT/HOT WATER — ENTIRE BUILDING
2026-02-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2026-02-08311: HEAT/HOT WATER — ENTIRE BUILDING
2026-02-08311: HEAT/HOT WATER — APARTMENT ONLY
2026-02-08Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-02-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2026-02-02311: HEAT/HOT WATER — APARTMENT ONLY
2026-02-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-02-02HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM WEST
2026-02-02HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT KITCHEN IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APARTM
2026-02-02HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM WEST
2026-02-02HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN AND BATH TUB IN THE BATHROOM LOCATED AT APT 5A, 5th S
2026-02-02HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN AND BATH TUB IN THE BATHROOM LOCATED AT APT 5A, 5th
2026-02-02HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM
2026-02-02HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT
2026-02-02HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APARTMENT
2026-02-02HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WALLS AND CEILING IN THE BATHROOM LOCA
2026-01-30311: HEAT/HOT WATER — APARTMENT ONLY
2026-01-30Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-01-29311: HEAT/HOT WATER — APARTMENT ONLY
2026-01-29Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-01-22311: HEAT/HOT WATER — ENTIRE BUILDING
2026-01-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2026-01-10311: HEAT/HOT WATER — APARTMENT ONLY
2026-01-10Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2025-12-17Rodent inspection: Stoppage done
2025-12-09Rodent inspection: Passed
2025-11-17HPD class I: §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE
2025-11-16311: PLUMBING — BASIN/SINK
2025-11-16Tenant complaint: PLUMBING — BASIN/SINK
2025-11-14DOB violation LBLVIO: VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION

The full timeline

2026
2026-10-08311: Illegal Tree Damage — Roots Damaged
2026-09-17Rodent inspection: Failed for Rat Activity
2026-08-21311: PLUMBING — WATER SUPPLY
2026-08-21Tenant complaint: PLUMBING — WATER SUPPLY
2026-08-20Rodent inspection: Failed for Rat Activity and Other Reason
2026-07-23311: Rodent — Rat Sighting
2026-06-15Rodent inspection: Passed
2026-04-29HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2026-03-20Boiler inspection
2026-03-20Boiler inspection
2026-02-27City emergency repair (OMO): install new self closing hinges to apt 3a, entrance door nyc hpd emergency operations division- ''essentials service wor$270
2026-02-11HPD class A: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2026-02-11HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASHBASIN AND BATHTUB IN THE BATHROOM LOCATED AT APT 3A, 3rd ST
2026-02-11HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BASEMENT AT BOILER ROOM
2026-02-11HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASHBASIN AND BATHTUB IN THE BATHROOM LOCATED AT APT 3A, 3rd STO
2026-02-11HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-02-11HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2026-02-11HPD class B: § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVI
2026-02-11HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2026-02-11HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST
2026-02-09311: HEAT/HOT WATER — ENTIRE BUILDING
2026-02-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2026-02-08311: HEAT/HOT WATER — ENTIRE BUILDING
2026-02-08311: HEAT/HOT WATER — APARTMENT ONLY
2026-02-08Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-02-08Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2026-02-02311: HEAT/HOT WATER — APARTMENT ONLY
2026-02-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-02-02HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM WEST
2026-02-02HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT KITCHEN IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APARTM
2026-02-02HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM WEST
2026-02-02HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN AND BATH TUB IN THE BATHROOM LOCATED AT APT 5A, 5th S
2026-02-02HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN AND BATH TUB IN THE BATHROOM LOCATED AT APT 5A, 5th
2026-02-02HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM
2026-02-02HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT
2026-02-02HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APARTMENT
2026-02-02HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WALLS AND CEILING IN THE BATHROOM LOCA
2026-01-30311: HEAT/HOT WATER — APARTMENT ONLY
2026-01-30Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-01-29311: HEAT/HOT WATER — APARTMENT ONLY
2026-01-29Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-01-22311: HEAT/HOT WATER — ENTIRE BUILDING
2026-01-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2026-01-10311: HEAT/HOT WATER — APARTMENT ONLY
2026-01-10Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2025
2025-12-17Rodent inspection: Stoppage done
2025-12-09Rodent inspection: Passed
2025-11-17HPD class I: §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE
2025-11-16311: PLUMBING — BASIN/SINK
2025-11-16Tenant complaint: PLUMBING — BASIN/SINK
2025-11-14DOB violation LBLVIO: VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
2025-08-25HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2B, 2nd STO
2025-08-25HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2025-08-25HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 2B, 2nd
2025-08-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT
2025-08-25HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STOR
2025-08-25HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2B, 2nd
2025-08-25HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM NORTH L
2025-08-20311: Boilers — Boiler - Defective/Inoperative/No Permit
2025-08-20311: DOOR/WINDOW — DOOR
2025-08-20311: UNSANITARY CONDITION — GARBAGE/RECYCLING STORAGE
2025-08-20311: PAINT/PLASTER — WALL
2025-08-20311: UNSANITARY CONDITION — PESTS
2025-08-20311: GENERAL — BELL/BUZZER/INTERCOM
2025-08-20311: UNSANITARY CONDITION — MOLD
2025-08-20311: ELECTRIC — WIRING
2025-08-20311: DOOR/WINDOW — WINDOW FRAME
2025-08-20311: PAINT/PLASTER — WALL
2025-08-20Tenant complaint: UNSANITARY CONDITION — PESTS
2025-08-20Tenant complaint: UNSANITARY CONDITION — GARBAGE/RECYCLING STORAGE
2025-08-20Tenant complaint: PAINT/PLASTER — WALL
2025-08-20Tenant complaint: DOOR/WINDOW — DOOR
2025-08-20Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2025-08-20Tenant complaint: UNSANITARY CONDITION — MOLD
2025-08-20Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2025-08-20Tenant complaint: PAINT/PLASTER — WALL
2025-08-20Tenant complaint: ELECTRIC — WIRING
2025-08-20DOB complaint, category ?
2025-08-16311: Street Light Condition — Street Light Out
2025-07-09Rodent inspection: Failed for Rat Activity
2025-06-11Rodent inspection: Failed for Rat Activity
2025-06-04HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2025-05-16Rodent inspection: Failed for Rat Activity
2025-05-09311: Rodent — Rat Sighting
2025-04-29311: Rodent — Signs of Rodents
2025-04-22311: Rodent — Rat Sighting
2025-04-19311: Rodent — Signs of Rodents
2025-04-18Rodent inspection: Failed for Rat Activity
2025-04-15311: Rodent — Rat Sighting
2025-03-29311: Missed Collection — Recycling - Paper
2025-03-21Boiler inspection
2025-03-21Boiler inspection
2025-02-22311: HEAT/HOT WATER — APARTMENT ONLY
2025-02-22Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2025-02-11311: HEAT/HOT WATER — ENTIRE BUILDING
2025-02-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2025-02-07Rodent inspection: Passed
2025-02-05311: Rodent — Rat Sighting
2025-02-02311: Rodent — Rat Sighting
2025-02-01311: HEAT/HOT WATER — APARTMENT ONLY
2025-02-01311: HEAT/HOT WATER — APARTMENT ONLY
2025-02-01Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2025-02-01Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2025-01-20311: HEAT/HOT WATER — APARTMENT ONLY
2025-01-20Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2024
2024-12-27Permit EW — ISSUED
2024-12-27Permit PL — ISSUED
2024-12-16Rodent inspection: Passed
2024-09-27311: Rodent — Rat Sighting
2024-09-26Rodent inspection: Failed for Rat Activity
2024-09-23311: Dirty Condition — Trash
2024-09-23DOB violation LBLVIO: VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
2024-08-22311: Rodent — Rat Sighting
2024-08-12HPD class B: § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FRO
2024-08-12HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS AT FRONT COURT
2024-08-12HPD class B: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF VERMIN FLIES AT FRONT COURT
2024-08-12HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 2B, 2nd STO
2024-08-12HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE TO PANEL AT WEST WA
2024-08-12HPD class B: § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS AT 2ND
2024-08-07311: Rodent — Condition Attracting Rodents
2024-08-07311: UNSANITARY CONDITION — PESTS
2024-08-07311: UNSANITARY CONDITION — GARBAGE/RECYCLING STORAGE
2024-08-07311: UNSANITARY CONDITION — PESTS
2024-08-07311: ELECTRIC — LIGHTING
2024-08-07311: GENERAL — BELL/BUZZER/INTERCOM
2024-08-07311: DOOR/WINDOW — WINDOW FRAME
2024-08-07311: PAINT/PLASTER — CEILING
2024-08-07311: PLUMBING — BATHTUB/SHOWER
2024-08-07311: UNSANITARY CONDITION — MOLD
2024-08-07311: FLOORING/STAIRS — FLOOR
2024-08-07311: PAINT/PLASTER — WALL
2024-08-07Tenant complaint: PLUMBING — BATHTUB/SHOWER
2024-08-07Tenant complaint: PAINT/PLASTER — CEILING
2024-08-07Tenant complaint: PAINT/PLASTER — WALL
2024-08-07Tenant complaint: UNSANITARY CONDITION — PESTS
2024-08-07Tenant complaint: ELECTRIC — LIGHTING
2024-08-07Tenant complaint: UNSANITARY CONDITION — PESTS
2024-08-07Tenant complaint: UNSANITARY CONDITION — GARBAGE/RECYCLING STORAGE
2024-08-07Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2024-08-07Tenant complaint: UNSANITARY CONDITION — MOLD
2024-08-07Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2024-08-07Tenant complaint: FLOORING/STAIRS — FLOOR
2024-07-31HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING AT VESTIBULE. , 1st STORY
2024-07-30311: GENERAL — CABINET
2024-07-30311: PAINT/PLASTER — CEILING
2024-07-30311: PAINT/PLASTER — WALL
2024-07-30311: PLUMBING — BASIN/SINK
2024-07-30311: GENERAL — BELL/BUZZER/INTERCOM
2024-07-30311: FLOORING/STAIRS — FLOOR
2024-07-30311: UNSANITARY CONDITION — MOLD
2024-07-30311: DOOR/WINDOW — WINDOW FRAME
2024-07-30311: ELECTRIC — OUTLET/SWITCH
2024-07-30311: GENERAL — BELL/BUZZER/INTERCOM
2024-07-30311: ELECTRIC — NO LIGHTING
2024-07-30311: Rodent — Condition Attracting Rodents
2024-07-30Tenant complaint: GENERAL — CABINET
2024-07-30Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2024-07-30Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2024-07-30Tenant complaint: FLOORING/STAIRS — FLOOR
2024-07-30Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2024-07-30Tenant complaint: PLUMBING — BASIN/SINK
2024-07-30Tenant complaint: ELECTRIC — NO LIGHTING
2024-07-30Tenant complaint: UNSANITARY CONDITION — MOLD
2024-07-30Tenant complaint: PAINT/PLASTER — WALL
2024-07-30Tenant complaint: ELECTRIC — OUTLET/SWITCH
2024-07-30Tenant complaint: PAINT/PLASTER — CEILING
2024-07-25Rodent inspection: Failed for Rat Activity
2024-07-17311: Rodent — Rat Sighting
2024-07-03311: Rodent — Rat Sighting
2024-07-03311: Sidewalk Condition — Broken Sidewalk
2024-06-20311: Sidewalk Condition — Broken Sidewalk
2024-06-20311: Rodent — Rat Sighting
2024-06-20311: Rodent — Signs of Rodents
2024-06-20311: Sidewalk Condition — Broken Sidewalk
2024-06-20311: Rodent — Rat Sighting
2024-06-19311: Rodent — Rat Sighting
2024-06-17311: Dirty Condition — Trash
2024-06-17311: Rodent — Rat Sighting
2024-06-16311: Encampment — N/A
2024-06-14FDNY inspection (RISK)
2024-06-06Rodent inspection: Passed
2024-04-01HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2024-03-01311: UNSANITARY CONDITION — MOLD
2024-03-01Tenant complaint: UNSANITARY CONDITION — MOLD
2024-01-29Rodent inspection: Passed
2023
2023-12-08Rodent inspection: Failed for Rat Activity
2023-10-25Agreement — from GARDEN OF EDEN ASSOCIATES, L.P. to THE CITY OF NEW YORK
2023-10-08HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FR
2023-10-08HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT
2023-10-08HPD class A: § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT
2023-10-08HPD class B: § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE AT SINK IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FR
2023-10-08HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RUBBER GASKET AT UPPER AND LOWER REFREGERATOR DOORS IN THE KITCHEN LOCATED
2023-10-08HPD class B: § 27-2005 HMC: REFIT LOWER WINDOW SASH AT 1ST WINDOW FROM EAST AT SOUTH IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTM
2023-10-08HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT
2023-10-08HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STO
2023-10-08HPD class C: § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FRO
2023-10-05311: APPLIANCE — REFRIGERATOR
2023-10-05311: FLOORING/STAIRS — FLOOR
2023-10-05311: PAINT/PLASTER — WALL
2023-10-05311: DOOR/WINDOW — WINDOW FRAME
2023-10-05311: PLUMBING — BASIN/SINK
2023-10-05311: GENERAL — COOKING GAS
2023-10-05311: UNSANITARY CONDITION — MOLD
2023-10-05311: Flooring/Stairs — Floor
2023-10-05311: Plumbing — Basin/Sink
2023-10-05311: Unsanitary Condition — Mold
2023-10-05311: Paint/Plaster — Wall
2023-10-05311: Door/Window — Window Frame
2023-10-05311: Appliance — Refrigerator
2023-10-05311: General — Cooking Gas
2023-10-05Tenant complaint: GENERAL — COOKING GAS
2023-10-05Tenant complaint: UNSANITARY CONDITION — MOLD
2023-10-05Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2023-10-05Tenant complaint: PAINT/PLASTER — WALL
2023-10-05Tenant complaint: PLUMBING — BASIN/SINK
2023-10-05Tenant complaint: APPLIANCE — REFRIGERATOR
2023-10-05Tenant complaint: FLOORING/STAIRS — FLOOR
2023-07-18Rodent inspection: Passed
2023-07-06HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FORMICA COUNTER TOP AT SINK IN THE KITCHEN LOCATED AT APT 2
2023-07-06HPD class C: § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT THE RANGE IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT
2023-07-06HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER AND UPPER WINDOW SASH AT EAST 1 WINDOW AT SOUTH I
2023-07-06HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER AND UPPER WINDOW SASH AT EAST 2 WINDOW AT SOUTH I
2023-07-06HPD class A: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER AND UPPER RUBBER GASKETS AT REFRIDGERATOR IN THE KITCHEN LOCATED AT
2023-06-27311: PLUMBING — BASIN/SINK
2023-06-27311: FLOORING/STAIRS — FLOOR
2023-06-27311: PAINT/PLASTER — WALL
2023-06-27311: DOOR/WINDOW — WINDOW FRAME
2023-06-27311: APPLIANCE — REFRIGERATOR
2023-06-27311: GENERAL — COOKING GAS
2023-06-27Tenant complaint: APPLIANCE — REFRIGERATOR
2023-06-27Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2023-06-27Tenant complaint: PAINT/PLASTER — WALL
2023-06-27Tenant complaint: GENERAL — COOKING GAS
2023-06-27Tenant complaint: FLOORING/STAIRS — FLOOR
2023-06-27Tenant complaint: PLUMBING — BASIN/SINK
2023-06-12Rodent inspection: Failed for Rat Activity
2023-04-08311: Residential Disposal Complaint — Waste Set Out Too Early or Too Late
2023-03-16HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2023-01-04City emergency repair (OMO): nyc hpd emergency operations division - ''essential service work'' at 304 west 120th street apartment 4a, install hinges$334
2023-01-03HPD litigation: Heat and Hot Water
2022
2022-12-14City emergency repair (OMO): nyc hpd emergency operations division - '' essential service work '' at bulkhead(south side) properly replace one door h$334
2022-12-13Rodent inspection: Passed
2022-11-17HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2B , 2nd STORY, 1
2022-11-17HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2B , 2nd STORY, 1st APARTMENT FROM EA
2022-11-17HPD class A: § 27-2005 ADM CODE REFIT UPPER AND LOWER WINDOW SASHES AT SOUTH WINDOW IN THE 5th ROOM FROM NORTH LOCATED AT APT 2B , 2nd STORY, 1st APARTME
2022-11-17HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM
2022-11-17HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2B , 2nd STORY, 1st APARTMENT
2022-11-17HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT 2B ,
2022-11-17HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS IN THE 5th ROOM FROM NORTH
2022-11-17HPD class B: § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2B , 2nd STORY, 1st APARTMENT FROM EAST A
2022-11-16HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT
2022-11-16HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ENTRANCE TO APARTMENT LOCATED AT AP
2022-11-16HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ROOF BULK HEAD
2022-11-15311: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-11-08Boiler inspection
2022-11-02HPD class I: §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE
2022-10-24Rodent inspection: Failed for Rat Activity
2022-10-07311: Rodent — Rat Sighting
2022-08-02HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM EAS
2022-08-02HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR AT ENTRANCE IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 2B, 2nd STORY
2022-08-02HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 2n
2022-08-02HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LO
2022-06-15Rodent inspection: Failed for Rat Activity
2022-05-26Rodent inspection: Failed for Other Reason
2022-04-23311: Missed Collection — Bulky Trash
2022-01-04311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-04Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021
2021-12-14Bedbug filing: 0 infested units
2021-11-29311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-29Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-10-14311: Sewer — Other Sewer Problem (Use Comments) (SZZ)
2021-09-26311: Noise - Residential — Loud Music/Party
2021-06-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE BATHROOM LOCA
2021-06-25HPD class B: § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM WES
2021-06-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 1st ROOM
2021-06-10311: APPLIANCE — REFRIGERATOR
2021-06-10311: PLUMBING — BATHTUB/SHOWER
2021-06-10311: FLOORING/STAIRS — FLOOR
2021-06-10Tenant complaint: APPLIANCE — REFRIGERATOR
2021-06-10Tenant complaint: PLUMBING — BATHTUB/SHOWER
2021-06-10Tenant complaint: FLOORING/STAIRS — FLOOR
2021-02-09Boiler inspection
2021-01-01Bedbug filing: 0 infested units
2020
2020-09-23311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2020-08-05311: Damaged Tree — Entire Tree Has Fallen Down
2020-03-19Boiler inspection
2020-01-26311: Noise - Commercial — Loud Music/Party
2020-01-24SMIS — from THE CITY OF NEW YORK
2019
2019-12-11Bedbug filing: 0 infested units
2019-11-20FDNY inspection (RISK)
2019-11-07HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER AND LOWER SASH WINDOW IN THE 3rd ROOM FROM NORTH LOCATED
2019-11-07HPD class B: § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT
2019-10-29Permit EW — ISSUED
2019-10-29Permit PL — ISSUED
2019-10-23Rodent inspection: Passed
2019-09-19Boiler inspection
2019-08-30Rodent inspection: Failed for Rat Activity
2019-05-30Boiler inspection
2019-05-30Boiler inspection
2019-05-24HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT
2019-01-29Bedbug filing: 0 infested units
2019-01-14Rodent inspection: Passed
2018
2018-10-18HPD class A: § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES, BALCONIES AND
2018-10-18HPD class B: § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .... IN THE ENTRANCE LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST
2018-10-18HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT
2018-10-18HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
2018-05-21Boiler inspection
2018-03-16Rodent inspection: Passed
2018-01-01311: HEAT/HOT WATER — ENTIRE BUILDING
2018-01-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017
2017-12-27311: HEAT/HOT WATER — ENTIRE BUILDING
2017-12-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-12-07Permit EW — ISSUED
2017-09-11Boiler inspection
2017-09-11Boiler inspection
2017-07-22311: Dirty Conditions — E2 Receptacle Violation
2017-06-19Rodent inspection: Passed
2017-04-26311: Noise - Residential — Loud Music/Party
2017-04-16311: Noise - Residential — Loud Music/Party
2017-04-16311: Noise - Residential — Loud Music/Party
2017-04-04Permit EW — ISSUED
2017-04-04Permit PL — ISSUED
2017-04-03Job filed: REPLACE EXISTING GAS FIRED SPACE HEATING AND DOMESTIC HOT WATER BOILERS. INSTALL INDIRECT HOT WATER HEATER.$36,000
2017-02-24311: Noise - Residential — Loud Music/Party
2017-02-22Rodent inspection: Passed
2016
2016-11-17Rodent inspection: Passed
2016-10-05Rodent inspection: Failed for Rat Activity
2016-03-29311: HEAT/HOT WATER — ENTIRE BUILDING
2016-03-29311: HEAT/HOT WATER — APARTMENT ONLY
2016-03-29Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-03-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2016-03-24311: HEAT/HOT WATER — APARTMENT ONLY
2016-03-24Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-03-10311: Noise - House of Worship — Banging/Pounding
2015
2015-12-31Rodent inspection: Passed
2015-11-11311: HEAT/HOT WATER — ENTIRE BUILDING
2015-11-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2015-06-16311: Noise - Street/Sidewalk — Loud Music/Party
2015-01-12HPD class B: SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE FIRE ESCAPE WINDOW LOWER SASH AND TOP SASH IN THE 1st ROOM FROM NORTH AT WE
2015-01-12HPD class C: § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE RADIATOR IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1A UPPER LEVEL, 1st STORY, 1st
2015-01-12HPD class C: SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK AT DOOR TO FIRE ESCAPE IN THE 1st ROOM FROM NORTH AT WEST LOCA
2015-01-08311: DOOR/WINDOW — WINDOW FRAME
2015-01-08311: HEAT/HOT WATER — APARTMENT ONLY
2015-01-08311: APPLIANCE — ELECTRIC/GAS RANGE
2015-01-08311: HEAT/HOT WATER — APARTMENT ONLY
2015-01-08Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2015-01-08Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2015-01-08Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2015-01-08Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2014
2014-09-16HPD class B: SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR BY SINK IN THE KITCHEN LOCATED AT APT 2B,
2014-09-16HPD class A: SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 2nd ROOM FROM NORT
2014-09-16HPD class B: SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STO
2014-09-16HPD class B: SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE REFRIGERATOR GASKETS IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APAR
2014-09-10Tenant complaint: DOOR/WINDOW — WINDOW FRAME
2014-09-10Tenant complaint: APPLIANCE — REFRIGERATOR
2014-09-10Tenant complaint: PAINT/PLASTER — WALL
2014-09-10Tenant complaint: FLOORING/STAIRS — FLOOR
2014-09-10Tenant complaint: GENERAL — CABINET
2014-03-08HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED A
2014-03-08HPD class C: SECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APA
2014-02-01311: PAINT/PLASTER — WALL
2014-02-01311: APPLIANCE — ELECTRIC/GAS RANGE
2014-02-01311: GENERAL — WINDOWS
2014-02-01311: APPLIANCE — REFRIGERATOR
2014-02-01Tenant complaint: APPLIANCE — REFRIGERATOR
2014-02-01Tenant complaint: GENERAL — WINDOWS
2014-02-01Tenant complaint: PAINT/PLASTER — WALL
2014-02-01Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2014-01-08311: HEATING — HEAT
2014-01-08Tenant complaint: HEATING — HEAT RELATED
2013
2013-09-18Rodent inspection: Passed
2013-04-21311: HEATING — HEAT
2013-04-21Tenant complaint: HEATING — HEAT RELATED
2012
2012-10-09HPD class A: SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WEST WALL IN THE 1st ROOM FROM NORTH AT WEST
2012-10-09HPD class B: SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM W
2012-10-09HPD class A: SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT EAST WALL IN THE BATHROOM LOCATED AT APT 1A,
2012-10-03311: PAINT - PLASTER — WALLS
2012-10-03311: PAINT - PLASTER — CEILING
2012-10-03Tenant complaint: PAINT/PLASTER — WALL
2012-10-03Tenant complaint: PAINT/PLASTER — CEILING
2012-08-31HPD class A: SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LO
2012-08-31HPD class B: SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST AT SOUTH L
2012-08-31HPD class A: SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT
2012-08-31HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORS IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd
2012-08-31HPD class B: SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 3A, 3rd STORY, 1st APAR
2012-08-28HPD class B: SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE
2012-08-28HPD class B: SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORT
2012-08-28HPD class A: SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WALLS AND CEILING THROUGHOUT IN T
2012-08-28HPD class B: SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2012-08-28HPD class B: SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK WASTE LINE IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APART
2012-08-28HPD class B: SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE CEILING IN THE 2nd ROOM FROM NORTH AT WES
2012-08-23311: GENERAL CONSTRUCTION — MOLD
2012-08-23311: PLUMBING — WATER-LEAKS
2012-08-23311: GENERAL CONSTRUCTION — LOCKS
2012-08-23311: PLUMBING — BASIN/SINK
2012-08-23311: GENERAL CONSTRUCTION — FLOOR
2012-08-23311: PAINT - PLASTER — CEILING
2012-08-23311: GENERAL CONSTRUCTION — MOLD
2012-08-23311: PAINT - PLASTER — WALLS
2012-08-23311: PLUMBING — WATER-LEAKS
2012-08-23311: GENERAL CONSTRUCTION — DOORS
2012-08-23Tenant complaint: GENERAL — FLOOR
2012-08-23Tenant complaint: PLUMBING — WATER-LEAKS
2012-08-23Tenant complaint: GENERAL — DOORS
2012-08-23Tenant complaint: PAINT/PLASTER — WALL
2012-08-23Tenant complaint: GENERAL — MOLD
2012-08-23Tenant complaint: PLUMBING — WATER-LEAKS
2012-08-23Tenant complaint: GENERAL — LOCKS
2012-08-23Tenant complaint: GENERAL — MOLD
2012-08-23Tenant complaint: PLUMBING — BASIN/SINK
2012-08-23Tenant complaint: PAINT/PLASTER — CEILING
2012-07-25311: Sanitation Condition — 12 Dead Animals
2012-06-26HPD litigation: False Certification Non-Lead
2012-05-30311: PLUMBING — WATER-SUPPLY
2012-05-30Tenant complaint: PLUMBING — WATER SUPPLY
2012-05-29311: PLUMBING — WATER-SUPPLY
2012-05-29311: PLUMBING — WATER-SUPPLY
2012-05-29Tenant complaint: PLUMBING — WATER SUPPLY
2012-05-29Tenant complaint: PLUMBING — WATER SUPPLY
2012-05-18Rodent inspection: Passed
2012-02-05311: Noise - Residential — Loud Music/Party
2012-02-03311: Noise - Residential — Loud Music/Party
2011
2011-08-02HPD class B: SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM E
2011-07-25311: PAINT - PLASTER — WALLS
2011-07-25311: GENERAL CONSTRUCTION — DOORS
2011-07-25311: NONCONST — RUBBISH
2011-07-25311: GENERAL CONSTRUCTION — MOLD
2011-07-25311: GENERAL CONSTRUCTION — WINDOWS
2011-07-25Tenant complaint: GENERAL — MOLD
2011-07-25Tenant complaint: GENERAL — DOORS
2011-07-25Tenant complaint: NONCONST — RUBBISH
2011-07-25Tenant complaint: GENERAL — WINDOWS
2011-07-25Tenant complaint: PAINT/PLASTER — WALL
2011-06-30311: Noise - Residential — Loud Music/Party
2011-06-20311: Noise - Residential — Loud Music/Party
2011-06-12311: Noise - Residential — Loud Music/Party
2011-05-03Rodent inspection: Passed
2011-03-18311: Noise - Residential — Loud Music/Party
2010
2010-12-23311: HEATING — HEAT
2010-12-23Tenant complaint: HEATING — HEAT RELATED
2010-10-02HPD class B: SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE DOOR LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM WEST A
2010-09-24311: PLUMBING — BASIN/SINK
2010-09-24311: PLUMBING — BASIN/SINK
2010-09-24311: GENERAL CONSTRUCTION — WINDOWS
2010-09-24Tenant complaint: PLUMBING — BASIN/SINK
2010-09-24Tenant complaint: PLUMBING — BASIN/SINK
2010-09-24Tenant complaint: GENERAL — WINDOWS
2010-08-10311: PLUMBING — BASIN/SINK
2010-08-10311: PLUMBING — BASIN/SINK
2010-08-10311: GENERAL CONSTRUCTION — WINDOWS
2010-08-10Tenant complaint: PLUMBING — BASIN/SINK
2010-08-10Tenant complaint: GENERAL — WINDOWS
2010-08-10Tenant complaint: PLUMBING — BASIN/SINK
2010-04-18311: Noise - Residential — Loud Music/Party
2010-04-05Rodent inspection: Passed
2010-02-24311: HEATING — HEAT
2010-02-24311: HEATING — HEAT
2010-02-24Tenant complaint: HEATING — HEAT RELATED
2010-02-24Tenant complaint: HEATING — HEAT RELATED
2010-02-23311: HEATING — HEAT
2010-02-23Tenant complaint: HEATING — HEAT RELATED
2009
2009-12-31DOB violation LBLVIO:
2009-07-23Tenant complaint: HEATING — HEAT RELATED
2008
2008-04-27Tenant complaint: GENERAL — WINDOWS
2006
2006-06-20Permit EW — ISSUED
2006-06-01Job filed: MASONRY REPAIRS ON THE EXTERIOR WALLAS INDICATED ON THE DRAWINGS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.$25,000
2006-06-01Job filed: MASONRY REPAIRS ON THE EXTERIOR WALLAS INDICATED ON THE DRAWINGS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.$25,000
2006-04-22ECB Non-Hazardous violation: EXIT EMERGENCY FIRE ESCAPE BLOCKED BY SIDEWALK TIED & PLANKING AT TIMEOF INSP NO ACCESS TO STREET LEVEL. REMEDY:REMOVE OBSTRUCTION$2,500
2006-04-21DOB complaint, category ?
2005
2005-12-07DOB complaint, category ?
2005-12-07DOB complaint, category ?
2004
2004-02-19Permit PL — ISSUED
2004-02-13DOB violation LL6291:
2004-02-06Permit EW — RE-ISSUED
2003
2003-12-22Mortgage $300,000 — from GARDEN OF EDEN ASSOCIATES, L.P. to THE CITY OF NEW YORK$300,000
2003-12-22Agreement — from GARDEN OF EDEN ASSOCIATES, L.P. to THE CITY OF NEW YORK
2003-12-22Agreement $8,507,581 — from GARDEN OF EDEN ASSOCIATES, L.P.; THE CITY OF NEW YORK to THE CITY OF NEW YORK; GARDEN OF EDEN ASSOCIATES, L.P.$8,507,581
2003-12-12Job filed: Sprinkler system in conjunction with gut rehab application 102485071. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.$39,000
2003-12-12Job filed: Sprinkler system in conjunction with gut rehab application 102485071. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.$39,000
2003-03-19DOB violation LL6291:
2003-03-06Permit AL — ISSUED
2003-01-24Permit EQ — ISSUED
2002
2002-09-24Mortgage assigned — from GARDEN OF EDEN ASSOCIATES, L.P. to CITY OF NEW YORK
2002-09-24Deed — from NYC HPD to GARDEN OF EDEN ASSOCIATES, L.P.
2002-09-24Agreement — from GARDEN OF EDEN ASSOCIATES, L.P. to NYC HPD
2002-09-24Agreement — from NYC HPD to GARDEN OF EDEN ASSOCIATES, L.P.
2002-09-24Agreement — from GARDEN OF EDEN ASSOCIATES, L.P. to NYC HPD
2002-09-24Mortgage $8,207,581 — from GARDEN OF EDEN ASSOCIATES, L.P. to NYC HPD$8,207,581
2002-09-19Permit PL — RE-ISSUED
2002-08-09Permit EQ — ISSUED
2002-07-31Job filed: Light Duty Shed in conjunction with 1024 85071. No storage as per TPPN 9
2002-07-31Job filed: Light Duty Shed in conjunction with 1024 85071. No storage as per TPPN 9
2002-07-19Permit AL — ISSUED
2002-03-26DOB violation LL6291:
2001
2001-02-27DOB violation LL6291:
2001-02-13Job filed: Rehabilitation of building, new walls, partitions, and plumbing.$560,000
1997
1997-02-07Permit PL — ISSUED
1996
1996-09-06Permit EW — ISSUED
1995
1995-08-29DOB violation LL6291:
1994
1994-09-01DOB violation LL6291:
1994-08-22Permit EQ — ISSUED
1988
1988-10-06Air permit (REGISTRATION), fuel: NO2FUEL
1977
1977-04-27Deed — from FINANCE ADMIN CITY NY; FINANCE ADMIN CITY NY to CITY OF NEW YORK; CITY OF NEW YORK
1977-04-27Deed — from FINANCE ADMIN CITY NY; FINANCE ADMIN CITY NY to CITY OF NEW YORK; CITY OF NEW YORK
1971
1971-09-02Deed — from ROTH ASSOCIATES INC to MARGASS REALTY CORP

Support this site Back to the building page