A modest record — below the level that usually signals systemic problems. More recorded distress than 62% of 25-99-unit residential buildings citywide. The citywide median for 25-99-unit residential buildings is 23.6 penalty
points per 10 units; this building carries 45.1. In ZIP 10463, 74% of residential buildings hold an A and
5% grade D or F.
How grades work
this building
A
B
C
Among 17,252 25-99-unit residential buildings citywide · left is less recorded distress, right is more
Open with the city right now
Open HPD violations
16 total — 8 class C (immediately hazardous), 7 class B, 1 class A. Oldest open since 1994-05-17.
Active vacate order
1 unit(s) under an unrescinded HPD vacate order
status snapshot refreshed weekly from HPD records
Patterns
4 heat or hot-water complaints in the last three years (winter 2023–24: 4).
No bedbug-infested units reported in the last three years of filings.
$655 in enforcement penalties imposed (ECB/OATH) in the last three years.
What 311 hears from this address
17 service requests in the last three years. Most common: Noise (3) · Animal (3) · HEAT/HOT WATER (2) · ELECTRIC (2) · UNSANITARY CONDITION (2) · SAFETY (2).
Filed construction activity
$48,000 in permitted construction work filed since
2016 (4 filings with a declared cost) — a rough measure of how actively
the owner maintains the building. Permit costs cover filed construction work only — they do not
capture routine maintenance or repairs done without a permit.
Rent-stabilization signals
Yes
Built before 1974 (1931)
Yes
Six or more residential units (30)
No
421-a / J-51 tax benefit on the current tax roll
2 of 3 signals present. This is the classic profile of a rent-stabilized building (pre-1974, 6+ units) — many units in such buildings remain stabilized. The definitive answer for any unit:
request its rent history from NYS Homes & Community Renewal (free, at hcr.ny.gov).
Registered with HPD — the names behind the building
Registered owner(s)
BLUE DIAMOND MARBLE LLC
Head officer
KONSTANTINE NALPANTIDIS
Managing agent
KATONAH PROPERTY MGMT
Last registered
2025-07-11
as filed by the owner in the building's HPD registration
What the city thinks it's worth
Tax year
City market value
Assessed value
2025
$1,479,000
$665,550
2026
$1,740,000
$783,000
2027
$1,566,000
$704,700
The city's market estimate has risen
6% between tax years 2025 and 2027.
Building systems
Heating fuel
NO4FUEL
Flood exposure
Not in the FEMA 1%-annual-chance floodplain (2015 preliminary maps).
Not in a hurricane evacuation zone.
Not in the city's stormwater (cloudburst) flood maps under any modeled scenario.
No street-flooding or sewer-backup complaints on record at this address.
Sources: FEMA flood maps (coastal), NYC DEP Stormwater Flood Maps
(cloudburst), NYC hurricane evacuation zones, and 311 records for this address.
Getting around
Subway
Marble Hill-225 St — 1 · 450 ft straight-line (about a 2-minute walk) · station accessibility: none
Bus
Nearest boarding stop: Broadway / W 225 St — Bx7 Bx20 · 400 ft
Citi Bike
Marble Hill Ave & W 227 St · 350 ft · station location as of 2026-09-23; live availability
Distances are straight-line, not walking routes. Transit locations from the MTA and
Citi Bike, bike facilities from NYC DOT, school zones from the DOE's 2024–25 maps.
17 311 service requests from this address in the last three years — 2 of them about heat or hot water.
311 will ask for the address, the apartment if the problem is inside, and what's wrong.
Contact details are optional for most complaints; food-poisoning reports can be anonymous. Complaints
appear in the city's public 311 data, usually within a day or two, and then in the Live from 311 box
on this page.
Most recent mortgage recorded against this lot: $2,000,000 on
2020-03-03 (lender: Mahopac Bank). Face amount at recording — it may have since been paid
down, refinanced or satisfied. View the recorded
document.
Date
Record
Amount
Per res. unit
2020-03-03
AL&R $2,000,000 — from BLUE DIAMOND MARBLE LLC to MAHOPAC BANK
$2,000,000
2020-03-03
Mortgage $2,000,000 — from BLUE DIAMOND MARBLE LLC to MAHOPAC BANK
$2,000,000
2006-12-13
AL&R $650,000 — from ASTORIA FEDERAL SAVINGS AND LOAN ASSOCIA to NALPANTIDIS, ESFTATHIOS
$650,000
2006-12-13
M&CON $650,000 — from NALPANTIDIS, ESFTATHIOS to ASTORIA FEDERAL SAVINGS AND LOAN ASSOCIA
$650,000
2001-11-16
Mortgage $499,500 — from NALPANTIDIS, EFSTATHIOS to NEW YORK COMMUNITY BANK
$499,500
Ten-year activity
100500
2017
2018
2019
2020
2021
74
2022
2023
2024
2025
2026
ConstructionEnforcementHousing & tenantsOwnership & moneyHealth & systems
Show as table
Year
Construction
Enforcement
Housing & tenants
Ownership & money
Health & systems
Total
2017
0
0
8
3
0
11
2018
0
7
34
0
1
42
2019
0
4
68
0
1
73
2020
0
1
31
4
2
38
2021
0
2
15
0
1
18
2022
0
1
71
0
2
74
2023
0
3
23
0
2
28
2024
13
1
15
0
1
30
2025
0
0
4
0
2
6
2026
0
1
19
0
3
23
This record is free. Keeping it free costs money. Servers, data pipelines, weekends. Pay what you want — a dollar helps.
311: Damaged Tree — Branch or Limb Has Fallen Down
2026-06-05
Vacate order: Fire Damage (1 units)
2026-06-05
Elevator permit: Device 1P13041, modify two new solid core door bucks to meet strict residential codes ensuring precise alignment with the sill and
2026-06-04
HPD class I: § 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS PO
2026-06-02
HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE AT CEILING, WALLS AND FLOORS , WINDOWS BROKEN IN THE ENTIRE AP
2026-06-02
HPD class C: § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FRO
2026-06-02
HPD class C: § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING , WALL OUTLETS AND LIGHT SWITCHES IN
2026-05-25
311: Animal-Abuse — Neglected
2026-05-22
311: Animal-Abuse — Chained
2026-05-16
311: Animal-Abuse — Neglected
2026-05-16
311: Unleashed Dog — Unleashed Dog in Public
2026-05-04
Bedbug filing: 0 infested units
2026-04-29
HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2026-06-07311: Damaged Tree — Branch or Limb Has Fallen Down
2026-06-05Vacate order: Fire Damage (1 units)
2026-06-05Elevator permit: Device 1P13041, modify two new solid core door bucks to meet strict residential codes ensuring precise alignment with the sill and$12,000
2026-06-04HPD class I: § 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS PO
2026-06-02HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE AT CEILING, WALLS AND FLOORS , WINDOWS BROKEN IN THE ENTIRE AP
2026-06-02HPD class C: § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FRO
2026-06-02HPD class C: § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING , WALL OUTLETS AND LIGHT SWITCHES IN
2026-05-25311: Animal-Abuse — Neglected
2026-05-22311: Animal-Abuse — Chained
2026-05-16311: Animal-Abuse — Neglected
2026-05-16311: Unleashed Dog — Unleashed Dog in Public
2026-05-04Bedbug filing: 0 infested units
2026-04-29HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2025
2025-12-12Facade (LL11) filing, cycle 10: SAFE
2025-08-26HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2025-08-06HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2025-08-06HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2024-10-01Permit General Construction — Signed-off
2024-10-01Permit Sidewalk Shed — Signed-off
2024-09-30Permit Supported Scaffold — Signed-off
2024-09-30Permit Sidewalk Shed — Signed-off
2024-09-26Job filed: INSTALLATION OF 300PSF SIDEWALK SHED AND PIPE SCAFFOLDING AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CH #33 OF THE NYC CODE 2022. NO CHANGE IN USE,$9,000
2024-07-29Tenant complaint: ELECTRIC — NO LIGHTING
2024-07-29Tenant complaint: ELECTRIC — POWER OUTAGE
2024-07-26Permit General Construction — Signed-off
2024-07-14Job filed: Demolish and rebuild damaged roof parapet wall down to and replace top floor window lintels. Filing also to address ECB violation # 35685279Z$25,000
2024-07-02Job filed: PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANC$9,000
2024-07-01Job filed: PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE $5,000
2024-06-28Boiler inspection
2024-05-23City emergency repair (OMO): defective latch at vestibule at vestibule door at 1st sty public hall.install new lock complete similar to existing.keep$890
2024-05-20ECB CLASS - 2 violation: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTE: AT TIME OF INSPECTION, I OBSERVED EXPOSURE #1 SOUTH (1) CRACKED/SPALL$655
2024-04-01HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2024-03-05City emergency repair (OMO): frame out the opening at the vestibule door with fire rated sheet rock . in the center ,make all necessary repairs to in$2,860
2024-01-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2024-01-11311: HEAT/HOT WATER — ENTIRE BUILDING
2024-01-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023
2023-11-03City emergency repair (OMO): make all necessary repairs to replace broken/defective door and jamb with new properly fire rated door and jamb similar $2,640
2023-11-02Eviction executed (1B)
2023-10-26ECB CLASS - 2 violation: AT TIME OF INSPECTION OBSERVED A SLEEPING MATTRESS STORED ON 1ST FLOORLOBBY. HOUSEHOLD DEBRIS STORED ON EMERGENCY EXIT PASSAGEWAY
2023-10-25311: General Construction/Plumbing — Egress - Doors Locked/Blocked/Improper/No Secondary Means
2023-03-15HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2023-02-18311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-16311: Missed Collection — Trash
2023-02-13HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BULKHEAD DOOR TO ROOF , 6th STORY
2023-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-06-16HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOWS AT WEST WALL LOWER SASH SPRING BALANCE. IN THE 2nd ROOM FROM NORTH AT WES
2022-06-16HPD class A: § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL .. IN THE BATHROOM LOCATED AT APT 5A, 5th STO
2022-06-16HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOORS AT SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APART
2022-06-16HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SASH LOCK AT LOWER WINDOW SASH IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT
2022-06-16HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER SASH SECOND WINDOW FROM SOUTH IN THE 1st ROOM FROM NORTH AT
2022-06-16HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER WINDOW SASH IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT
2021-11-29ECB CLASS - 1 violation: CLASS 1 VIOLATION ISSUED RTS, UPON INSPECTION THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING A HAZARDOUS CONDITION AS PER 1RCNY$1,250
2021-11-08311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2021-09-21Boiler inspection
2021-09-13311: Elevator — Elevator - Single Device On Property/No Alternate Service
2021-09-13DOB complaint, category ?
2021-05-21HPD class A: § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON
2021-05-21HPD class C: § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO H
2021-05-21HPD class A: § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGE
2021-05-21HPD class A: § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES
2021-05-21HPD class A: § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND
2021-05-21HPD class A: § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISS
2021-05-21HPD class A: § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM
2021-05-21HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2021-05-19311: HEAT/HOT WATER — ENTIRE BUILDING
2021-05-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-02-27Bedbug filing: 0 infested units
2020
2020-12-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2020-12-26311: HEAT/HOT WATER — ENTIRE BUILDING
2020-12-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2020-12-21311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2020-12-19311: HEAT/HOT WATER — ENTIRE BUILDING
2020-12-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2020-12-09311: HEAT/HOT WATER — ENTIRE BUILDING
2020-12-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2020-11-05Boiler inspection
2020-10-17311: HEAT/HOT WATER — ENTIRE BUILDING
2020-10-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2020-09-29Elevator permit: A software upgrade to the existing controller to comply with door lock monitoring system as per ASME A17.3 of 2002 as modified by $13,176
2020-03-03AL&R $2,000,000 — from BLUE DIAMOND MARBLE LLC to MAHOPAC BANK$2,000,000
2020-03-03Mortgage $2,000,000 — from BLUE DIAMOND MARBLE LLC to MAHOPAC BANK$2,000,000
2020-02-18Eviction executed (4E)
2020-02-09311: Sanitation Condition — 12 Dead Animals
2020-01-28311: HEAT/HOT WATER — ENTIRE BUILDING
2020-01-28311: HEAT/HOT WATER — ENTIRE BUILDING
2020-01-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2020-01-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2020-01-02HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BASEMENT DOOR LOCKED AT BOILER ROOM
2020-01-02HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT THE UPPER WINDOW SASH IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT
2020-01-02HPD class A: § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE STEAM RISER IN THE 1st BATHROOM FROM EAST LOCATED AT APT 2E, 2nd STOR
2020-01-02HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ........ IN THE ENTRANCE LOCATED AT
2020-01-02HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTERBALANCE AT THE UPPER WINDOW SASH IN THE 1st ROOM FROM EAST AT NORTH LOCATE
2020-01-02HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORT
2019
2019-12-29311: HEAT/HOT WATER — ENTIRE BUILDING
2019-12-19311: HEAT/HOT WATER — ENTIRE BUILDING
2019-12-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-10-25HPD class I: §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE
2019-10-09Boiler inspection
2019-10-09311: HEAT/HOT WATER — ENTIRE BUILDING
2019-10-09311: HEAT/HOT WATER — ENTIRE BUILDING
2019-10-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-10-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-10-05311: HEAT/HOT WATER — ENTIRE BUILDING
2019-10-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-06-14HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 6th STORY
2019-06-14HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND SOUTH WALL AT PUBLIC HALL, 6th STORY
2019-06-14HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND SOUTH WALL AT PUBLIC
2019-06-11Eviction executed (3A)
2019-06-04HPD class B: § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE , IN THE ENTRANCE LOCATED AT APT 3E
2019-06-02311: HEAT/HOT WATER — APARTMENT ONLY
2019-06-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2019-05-11311: Noise - Vehicle — Car/Truck Music
2019-04-13HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FR
2019-04-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST LOCATED AT APT 6C, 6th
2019-04-13HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE 3rd ROOM FROM EAST L
2019-04-13HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6C, 6th STORY, 2n
2019-04-13HPD class B: § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 6
2019-04-13HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT AP
2019-04-13HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM WES
2019-04-03DOB violation AEUHAZ1: FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2019-03-07Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-03-07HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM NOR
2019-03-07HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 2n
2019-03-06311: HEAT/HOT WATER — ENTIRE BUILDING
2019-03-06311: HEAT/HOT WATER — ENTIRE BUILDING
2019-03-06311: HEAT/HOT WATER — ENTIRE BUILDING
2019-03-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-03-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-03-06Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-03-05311: HEAT/HOT WATER — ENTIRE BUILDING
2019-03-05Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-02-13311: HEAT/HOT WATER — ENTIRE BUILDING
2019-02-13Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-02-12311: HEAT/HOT WATER — APARTMENT ONLY
2019-02-12Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2019-02-09311: HEAT/HOT WATER — ENTIRE BUILDING
2019-02-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-01-26311: HEAT/HOT WATER — ENTIRE BUILDING
2019-01-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-01-25311: HEAT/HOT WATER — ENTIRE BUILDING
2019-01-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-01-23311: HEAT/HOT WATER — ENTIRE BUILDING
2019-01-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2019-01-11311: Elevator — Elevator - Single Device On Property/No Alternate Service
2019-01-11DOB complaint, category ?
2019-01-10ECB CLASS - 1 violation: (CEASE USE)05.A.10(C/U),05.J.01(C/U),25.M.07,40.P.16=(05,A,10)CEASE USE ITEM DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH DISABLED $1,250
2019-01-10ECB CLASS - 1 violation: 29-R-05=WORK WITHOUT PERMIT.PART NUMBER (29)DOOR OPERATOR AND PART WAS INSTALLED WITHOUT PERMIT BEING OBTAINED AND APPLICATION BEI$1,250
2018
2018-12-14311: Elevator — Elevator - Single Device On Property/No Alternate Service
2018-12-05311: Elevator — Elevator - Single Device On Property/No Alternate Service
2018-12-05311: Elevator — Elevator - Single Device On Property/No Alternate Service
2018-12-05DOB complaint, category ?
2018-12-05DOB complaint, category ?
2018-11-27311: HEAT/HOT WATER — ENTIRE BUILDING
2018-11-27311: HEAT/HOT WATER — ENTIRE BUILDING
2018-11-27311: HEAT/HOT WATER — ENTIRE BUILDING
2018-11-27311: HEAT/HOT WATER — ENTIRE BUILDING
2018-11-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-11-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-11-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-11-27Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-11-05ECB CLASS - 2 violation: 05J10,02X10,40P16,70P16. 05J10-RMDY ADJUST CAR DOOR ON THE RETURN END02X10-REPAIR ALARM BELL ON CAR; 40P16-RMDY: PROVIDE MEANS OF$625
2018-10-10311: Elevator — Elevator - Single Device On Property/No Alternate Service
2018-10-10DOB complaint, category ?
2018-10-05HPD class B: § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT
2018-10-04311: HEAT/HOT WATER — ENTIRE BUILDING
2018-10-04Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-09-27311: HEAT/HOT WATER — ENTIRE BUILDING
2018-09-26Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-09-05DOB violation AEUHAZ1: FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2018-06-07ECB CLASS - 1 violation: CEASE USE. 5A10, 5J10, 2X10, 99BB5 5A10-UPON INSPECTION OF DEVICE IT WAS FOUND THAT DOOR RESTRICTOR ARM WAS MISSING.REMEDY: PROVI$1,250
2018-05-11311: Elevator — Elevator - Single Device On Property/No Alternate Service
2018-05-08311: Elevator — Elevator - Single Device On Property/No Alternate Service
2018-05-04DOB violation E:
2018-03-22311: HEAT/HOT WATER — ENTIRE BUILDING
2018-03-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-03-22HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 6E,
2018-03-22HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 6
2018-03-22HPD class C: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM EAST LOCA
2018-03-15Eviction executed (1D)
2018-03-09311: HEAT/HOT WATER — ENTIRE BUILDING
2018-03-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-01-13311: HEAT/HOT WATER — APARTMENT ONLY
2018-01-13Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2017
2017-11-16Eviction executed (5B)
2017-11-03Deed — from NALPANTIDIS, EFSTATHIOS to BLUE DIAMOND MARBLE LLC
2017-11-03PAT — from NALPANTIDIS, EFSTATHIOS to NALPANTIDIS, CONSTANTINE
2017-02-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2016
2016-12-20HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS IN THE BATHROOM LOCATED AT APT 5B, 5th ST
2016-12-20HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE BATHROOM LOCATED AT APT 5B, 5th STORY,
2016-12-20HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER WINDOW SASH COUNTER BALANCE IN THE 1st ROOM FROM NORTH LOCATED AT APT 5B, 5
2016-12-20HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING IN THE FOYER LOCATED AT APT 5B, 5
2016-12-20HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALL AND CEILING IN THE 1st ROOM FROM NORTH LOCATED
2016-12-20HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE SINK CABINET BASE IN THE KITCHENETTE LOCATED AT APT 5B, 5th STORY, 1st APARTMENT
2016-12-20HPD class A: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MECHANICAL SINK STOPPER IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 1st APARTM
2016-12-20HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BASE CABINET AT WASH BASIN IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 1st APA
2016-12-20HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 5B,
2016-12-20HPD class B: § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ,, IN THE BATHROOM LOCATED AT
2016-12-20HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE KNOBS ON CLOSET DOORS IN THE PRIVATE HALLWAY LOCATED AT APT 5B, 5th STORY, 1st AP
2016-12-20HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE TILE GROUT AT WALLS IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 1st APARTMENT F
2016-12-20HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR AND LOCK ASSEMBLY IN THE ENTRANCE LOCATED AT APT 5B, 5th STORY, 1st APARTME
2016-12-20HPD class B: § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYP
2016-12-20HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING IN THE 1st ROOM FROM NORTH LOCATE
2016-07-01HPD class B: § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE NORTH FIRE PASSAGEWAY.
2016-04-06Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-02-05311: HEAT/HOT WATER — APARTMENT ONLY
2016-02-05Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-01-29City emergency repair (OMO): apartment 6d trace and repair the leak over ceing from roof approx. 400 sq. ft and replace damged ceilings and walls in $1,992
2015
2015-12-28Tenant complaint: DOOR/WINDOW — DOOR
2015-12-28Tenant complaint: ELECTRIC — NO LIGHTING
2015-12-28Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2015-12-11HPD class A: § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGE
2015-12-11HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 6th STORY
2015-12-11HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCKSET AT THE BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
2015-12-11HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MORTAR AT THE EAST AND NORTH PARAPET WALLS AT ROOF
2015-12-11HPD class A: § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND
2015-12-11HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE THE FIRE RETARDANT CEILING AT PUBLIC HALL, 6th STORY
2015-12-11HPD class A: § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX .. A
2015-12-11HPD class C: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE FOYER LOCATED AT APT 6D
2015-12-11HPD class B: § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BULKHEAD
2015-12-11HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT CEILING AND WALLS AT BULKHEAD AT PUBLIC HALL
2015-12-11HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS AT BULKHEAD AT PUBLIC HALL
2015-12-11HPD class B: § 27-2005 ADM CODE PROVIDE WIRE SCREEN ABOVE AND BELOW GLASS PANES AT SKYLIGHT AT BULKHEAD
2015-12-11HPD class C: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH AT
2015-12-11HPD class B: § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT
2015-12-11HPD class C: § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT THE NORTH WALL (APPROX 16 SQ FT) AND AT WEST WALL
2015-12-11HPD class C: § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT THE EAST WALL (APPROX 16 SQ FT) AND AT NORTH WALL
2015-12-11HPD class B: § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE BATHTUB IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM
2015-12-11HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2015-12-11HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE 2nd ROOM
2015-12-04311: HEAT/HOT WATER — APARTMENT ONLY
2015-12-04Tenant complaint: WATER LEAK — HEAVY FLOW
2015-12-04Tenant complaint: OUTSIDE BUILDING — ROOF DOOR/HATCH
2015-11-09HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MORTISE LOCK AT ENTRANCE DOOR TO 1ST STORY AT PUBLIC HALL
2015-11-09HPD class A: § 27-2005 ADM CODE REFIT ENTRANCE DOOR TO BUILDING 1ST STORY AT PUBLIC HALL
2015-10-19311: DOOR/WINDOW — DOOR
2015-10-19311: HEAT/HOT WATER — ENTIRE BUILDING
2015-10-19Tenant complaint: DOOR/WINDOW — DOOR
2015-10-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2015-10-11311: Noise - Residential — Loud Talking
2015-10-10311: Noise - Residential — Loud Talking
2015-10-01HPD class I: §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE
2015-03-25HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING ASSEMBLY AT ENTRANCE DOOR TO BUILDING
2015-03-25HPD class A: § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGE
2015-03-08HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL-BUZZER INTERCOM SYSTEM FROM 1ST. STORY PUBLIC HALL VESTIBULE TO IN THE FOYER
2015-03-08HPD class A: § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGE
2015-03-08HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK ON BUILDING ENTRANCE DOOR , 1st STORY
2015-02-07HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTICE LOCK OF DOOR, AT LOBBY, 1st STORY
2015-02-03311: HEAT/HOT WATER — ENTIRE BUILDING
2015-02-03Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2015-02-02311: HEAT/HOT WATER — ENTIRE BUILDING
2015-02-02311: HEAT/HOT WATER — ENTIRE BUILDING
2015-02-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2015-02-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2015-02-02HPD class I: §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE
2015-01-31311: HEAT/HOT WATER — ENTIRE BUILDING
2015-01-31311: HEAT/HOT WATER — ENTIRE BUILDING
2015-01-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2015-01-31Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2015-01-26311: HEAT/HOT WATER — APARTMENT ONLY
2015-01-26Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2015-01-26HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING 130 DEGREES IN THE KITCHEN AND IN THE BATHROOM LOCATED
2015-01-24311: HEAT/HOT WATER — ENTIRE BUILDING
2015-01-24Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2015-01-11Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2015-01-11Tenant complaint: ELECTRIC — NO LIGHTING
2015-01-07ECB CLASS - 2 violation: 05M07,39O02,39L10,70Z02,40O02,42L09,68M07,52Q03,61L11,42AL09,40L11,60M07,20L11,71L10,05I11. 05-ZONE RESTRICTOR; 42-JUMPERS; 42A-M$250
2015-01-07ECB CLASS - 2 violation: 21R05 WORK W/O PERMIT PART NUMBER 221 AND PART WAS INSTALLED W/O PERMIT BEING OBTAINED AND APPLICATION BEING FILED. RMDY: FILE APP$800
2015-01-02DOB violation E:
2014
2014-12-29ECB CLASS - 1 violation: 01L10, 40M07,41M07. 01-IN CAR STOP SWITCH DEFECTIVE MUST REPAIR BACK TO SERVICE IMMEDIATELY ONLY ELEVATOR IN BLDG; 40-PROVIDE KEYS$1,000
2014-10-09City emergency repair (OMO): at front building: properly repair the defective door entrance. repair the broken lock, restore door to proper work orde
2014-10-02HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE DOOR LOCK , 1st STORY
2014-09-29311: DOOR/WINDOW — DOOR
2014-09-29Tenant complaint: DOOR/WINDOW — DOOR
2014-09-18HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR AT ENTRANCE AT LOBBY
2014-09-18HPD class A: § 27-2005 ADM CODE REFIT DOOR TO FRAME AT ENTRANCE AT LOBBY
2014-07-23311: Elevator — Elevator - Defective/Not Working
2014-07-23311: Elevator — Elevator - Defective/Not Working
2014-07-23311: DOOR/WINDOW — DOOR
2014-07-23Tenant complaint: DOOR/WINDOW — DOOR
2014-07-23DOB complaint, category ?
2014-07-23DOB complaint, category ?
2014-07-23ECB CLASS - 2 violation: 21L10 - DOOR INTERLOCKS NOT WORKING PROPERLY MUST PROPERLY REPAIR. AND RESCHEDULE FOR TEST.
2014-07-22HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE REGULATION LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
2014-07-09311: Elevator — Elevator - Defective/Not Working
2014-07-09DOB complaint, category ?
2014-07-08311: Elevator — Elevator - Defective/Not Working
2014-07-08311: Elevator — Elevator - Defective/Not Working
2014-04-16HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT ENTRANCE DOOR TO BUILDING.
2014-04-12311: DOOR/WINDOW — DOOR
2014-04-12Tenant complaint: DOOR/WINDOW — DOOR
2014-04-11Rodent inspection: Passed
2014-03-25HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DEPARTMENT REGULATION TYPE HEAVY DUTY LOCK AND LATCH SET AT BUIDING ENTRANCE DOOR
2014-03-17HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY
2014-03-17HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2014-03-17HPD class A: § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM
2014-03-17HPD class B: § 27-2053 ADM CODE PROVIDE DWELLING WITH A JANITOR OR RESPONSIBLE PERSON OR JANITORIAL SERVICE., 1st STORY
2014-03-11311: Noise - Residential — Loud Talking
2014-03-06Rodent inspection: Failed for Rat Activity and Other Reason
2014-03-05ECB CLASS - 2 violation: 21L10,16L10,70O02,70Z09,40P16. 16/21L10- PULL ON 2ND FLR HOISTWAY DOORSTOPS ELEVATOR IN FLIGHT; 70-REMOVE WATER AND CLEAN PIT; 46-$500
2014-02-22311: Elevator — Elevator - Defective/Not Working
2014-02-22311: GENERAL — LOCKS
2014-02-22Tenant complaint: GENERAL — LOCKS
2014-02-22DOB complaint, category ?
2014-01-24HPD class B: § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNS
2013-11-16Tenant complaint: HEATING — HEAT RELATED
2013-11-16Tenant complaint: PAINT/PLASTER — WALL
2013-11-05311: HEATING — HEAT
2013-11-05Tenant complaint: HEATING — HEAT RELATED
2013-11-01311: HEATING — HEAT
2013-11-01Tenant complaint: HEATING — HEAT RELATED
2013-10-31HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUT
2013-10-31HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT CELLAR
2013-10-27311: HEATING — HEAT
2013-10-27Tenant complaint: HEATING — HEAT RELATED
2013-10-25311: HEATING — HEAT
2013-10-25Tenant complaint: HEATING — HEAT RELATED
2012-05-15HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR, IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1s
2012-05-15HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLO0R, IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT A
2012-05-02311: GENERAL CONSTRUCTION — FLOOR
2012-05-02311: ELECTRIC — LIGHTING
2012-05-02311: PLUMBING — TOILET
2012-05-02Tenant complaint: ELECTRIC — LIGHTING
2012-05-02Tenant complaint: PLUMBING — TOILET
2012-05-02Tenant complaint: GENERAL — FLOOR
2012-04-27311: HEATING — HEAT
2012-04-27Tenant complaint: HEATING — HEAT RELATED
2012-04-24311: HEATING — HEAT
2012-04-24Tenant complaint: HEATING — HEAT RELATED
2012-04-11DOB violation E:
2012-03-31311: HEATING — HEAT
2012-03-31311: HEATING — HEAT
2012-03-31Tenant complaint: HEATING — HEAT RELATED
2012-03-31Tenant complaint: HEATING — HEAT RELATED
2012-03-30311: HEATING — HEAT
2012-03-30311: HEATING — HEAT
2012-03-30Tenant complaint: HEATING — HEAT RELATED
2012-03-30Tenant complaint: HEATING — HEAT RELATED
2012-03-26311: HEATING — HEAT
2012-03-26311: HEATING — HEAT
2012-03-26Tenant complaint: HEATING — HEAT RELATED
2012-03-26Tenant complaint: HEATING — HEAT RELATED
2012-03-23311: HEATING — HEAT
2012-03-23Tenant complaint: HEATING — HEAT RELATED
2012-03-22311: HEATING — HEAT
2012-03-22Tenant complaint: HEATING — HEAT RELATED
2012-03-14City emergency repair (OMO): at apt# 1b ------- bathroom ------- trace and repair the source of concealed water causing damage to ceiling and east wa$980
2012-03-10311: HEATING — HEAT
2012-03-10311: HEATING — HEAT
2012-03-10Tenant complaint: HEATING — HEAT RELATED
2012-03-10Tenant complaint: HEATING — HEAT RELATED
2012-03-09311: HEATING — HEAT
2012-03-09Tenant complaint: HEATING — HEAT RELATED
2012-03-01HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM N
2012-03-01HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STOR
2012-03-01HPD class B: § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE OR MISSING WASH BASIN IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NO
2012-03-01HPD class B: § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE OR MISSING WATER SUPPLY PIPES FOR HOT AND COLD WATER IN THE BATHROOM
2012-03-01HPD class B: § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW A
2012-03-01HPD class C: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR UNKEYED CEILING INSIDE THE CLOSET IN THE 3
2012-02-27311: HEATING — HEAT
2012-02-27311: HEATING — HEAT
2012-02-27Tenant complaint: HEATING — HEAT RELATED
2012-02-27Tenant complaint: HEATING — HEAT RELATED
2012-02-26311: HEATING — HEAT
2012-02-26Tenant complaint: HEATING — HEAT RELATED
2012-02-25311: HEATING — HEAT
2012-02-25Tenant complaint: HEATING — HEAT RELATED
2011-09-06HPD class B: § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE EXIT AT FIRE PASSAGE W
2011-09-06HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR
2011-08-31311: GENERAL CONSTRUCTION — LOCKS
2011-08-31Tenant complaint: GENERAL — LOCKS
2011-08-04HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2011-08-04HPD class A: § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM
2011-08-04HPD class A: § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON
2011-08-04HPD class A: § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND
2011-08-04HPD class B: § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNS
2011-08-04HPD class A: § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISS
2011-08-04HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT FRONT ENTRANCE DOOR TO BUILDING , 1st STORY
2011-08-01311: GENERAL CONSTRUCTION — LOCKS
2011-08-01311: ELECTRIC — ELECTRIC-SUPPLY
2011-08-01311: GENERAL CONSTRUCTION — DOORS
2011-08-01Tenant complaint: ELECTRIC — ELECTRIC-SUPPLY
2011-08-01Tenant complaint: GENERAL — DOORS
2011-08-01Tenant complaint: GENERAL — LOCKS
2011-07-05311: Elevator — Elevator - Defective/Not Working
2011-06-08HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY
2011-06-03311: HEATING — HEAT
2011-06-03Tenant complaint: HEATING — HEAT RELATED
2011-05-20HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MORTICE LOCK OF DOOR, AT LOBBY
2011-05-18311: GENERAL CONSTRUCTION — LOCKS
2011-05-18311: HEATING — HEAT
2011-05-18311: NONCONST — RUBBISH
2011-05-18311: NONCONST — RUBBISH
2011-05-18311: CONSTRUCTION — ELEVATOR
2011-05-18Tenant complaint: NONCONST — RUBBISH
2011-05-18Tenant complaint: NONCONST — RUBBISH
2011-05-18Tenant complaint: GENERAL — LOCKS
2011-05-18Tenant complaint: CONSTRUCTION — ELEVATOR
2011-05-18Tenant complaint: HEATING — HEAT RELATED
2011-05-11City emergency repair (OMO): apt. # 5b : kitchenette : trace, locate andrepair the source of water leak above ceilings and repair with similar materi$590
2011-05-05HPD class B: § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF USED FURNITURE ON STAIR TO BULKHEAD , 6th STORY
2011-05-05HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT THE STREET ENTRANCE DOOR , 1st STORY
2011-05-05HPD class A: § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX SIGN
2011-05-05HPD class C: § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO H
2011-05-05HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2011-05-05HPD class A: § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM
2011-05-05HPD class A: § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON
2011-05-05HPD class A: § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND
2011-05-02311: GENERAL CONSTRUCTION — DOORS
2011-05-02Tenant complaint: GENERAL — DOORS
2011-04-27311: HEATING — HEAT
2011-04-27Tenant complaint: HEATING — HEAT RELATED
2011-04-20311: HEATING — HEAT
2011-04-20Tenant complaint: HEATING — HEAT RELATED
2011-04-19311: HEATING — HEAT
2011-04-19Tenant complaint: HEATING — HEAT RELATED
2011-04-19HPD class B: § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW A
2011-04-19HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM W
2011-04-16311: HEATING — HEAT
2011-04-16311: HEATING — HEAT
2011-04-16Tenant complaint: HEATING — HEAT RELATED
2011-04-16Tenant complaint: HEATING — HEAT RELATED
2011-04-13311: HEATING — HEAT
2011-04-13311: HEATING — HEAT
2011-04-13Tenant complaint: HEATING — HEAT RELATED
2011-04-13Tenant complaint: HEATING — HEAT RELATED
2011-04-11HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH GLASS AT NORTH 2 WINDOW IN THE KITCHEN LOCATED AT APT 5B, 5th STORY,
2011-04-11HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE KITCHEN LOCATED AT A
2011-04-10311: HEATING — HEAT
2011-04-10Tenant complaint: HEATING — HEAT RELATED
2011-04-08311: PAINT - PLASTER — CEILING
2011-04-08311: PLUMBING — WATER-LEAKS
2011-04-08311: PLUMBING — WATER-SUPPLY
2011-04-08311: HEATING — HEAT
2011-04-08311: HEATING — HEAT
2011-04-08Tenant complaint: HEATING — HEAT RELATED
2011-04-08Tenant complaint: PLUMBING — WATER SUPPLY
2011-04-08Tenant complaint: HEATING — HEAT RELATED
2011-04-05HPD class A: § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX , AT
2011-04-05HPD class A: § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND
2011-04-05HPD class A: § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON
2011-04-05HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY
2011-04-04HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK OF DOOR, AT LOBBY, 1st STORY
2011-04-02311: HEATING — HEAT
2011-04-02Tenant complaint: HEATING — HEAT RELATED
2011-03-31311: PLUMBING — WATER-LEAKS
2011-03-31311: PLUMBING — WATER-LEAKS
2011-03-31311: HEATING — HEAT
2011-03-31311: PLUMBING — WATER-LEAKS
2011-03-31311: GENERAL CONSTRUCTION — LOCKS
2011-03-31Tenant complaint: HEATING — HEAT RELATED
2011-03-15HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY METAL DOOR ENTRANCE TO BUILDING
2011-03-15HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 6
2011-03-15HPD class C: § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO H
2011-03-15HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 6D, 6th STORY
2011-03-15HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM .. AT PUBLIC HALL, 1st STORY
2011-03-15HPD class B: § 27-2005 ADM CODE PROVIDE APPRIVED WIRE SCREEN BELOW SKYLIGHT AT BULKHEAD STAIR TO ROOF LOCATED AT APT 6D, 6th STORY
2011-03-11HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK OF DOOR, AT LOBBY
2011-03-04311: GENERAL CONSTRUCTION — LOCKS
2011-03-04Tenant complaint: GENERAL — LOCKS
2011-02-14311: Elevator — Elevator - Defective/Not Working
2011-02-14DOB complaint, category ?
2011-02-13311: ELECTRIC — ELECTRIC-SUPPLY
2011-02-13Tenant complaint: ELECTRIC — ELECTRIC-SUPPLY
2011-02-08311: HEATING — HEAT
2011-02-08Tenant complaint: HEATING — HEAT RELATED
2011-02-07311: GENERAL CONSTRUCTION — DOORS
2011-02-07Tenant complaint: GENERAL — DOORS
2010
2010-12-30HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK OF DOOR, ( FROM VESTIBULE TO LOBBY ) AT LOBBY, 1st STORY
2010-12-06311: GENERAL CONSTRUCTION — DOORS
2010-12-06311: HEATING — HEAT
2010-12-06Tenant complaint: GENERAL — DOORS
2010-12-06Tenant complaint: HEATING — HEAT RELATED
2010-12-06HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE L0CK OF VESTIBULE DOOR, AT LOBBY, 1st STORY
2010-12-03311: HEATING — HEAT
2010-12-03Tenant complaint: HEATING — HEAT RELATED
2010-11-10311: HEATING — HEAT
2010-11-10Tenant complaint: HEATING — HEAT RELATED
2010-11-09311: PAINT - PLASTER — WALLS
2010-11-09311: HEATING — HEAT
2010-11-09311: GENERAL CONSTRUCTION — MAIL-BOX
2010-11-09Tenant complaint: HEATING — HEAT RELATED
2010-11-09Tenant complaint: PAINT/PLASTER — WALL
2010-11-09Tenant complaint: GENERAL — MAILBOX
2010-11-07311: HEATING — HEAT
2010-11-07Tenant complaint: HEATING — HEAT RELATED
2010-11-05311: HEATING — HEAT
2010-11-05Tenant complaint: HEATING — HEAT RELATED
2010-11-02311: HEATING — HEAT
2010-11-02Tenant complaint: HEATING — HEAT RELATED
2010-11-01311: HEATING — HEAT
2010-11-01Tenant complaint: HEATING — HEAT RELATED
2010-10-19HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2010-10-19HPD class A: § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND
2010-10-18311: GENERAL CONSTRUCTION — DOORS
2010-10-18311: HEATING — HEAT
2010-10-18Tenant complaint: GENERAL — DOORS
2010-10-18Tenant complaint: HEATING — HEAT RELATED
2010-10-17311: HEATING — HEAT
2010-10-17Tenant complaint: HEATING — HEAT RELATED
2010-08-24HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETADANT AT WEST AND EAST WALLS AT BULK HEAD AT PUBLIC
2010-08-24HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CRACK LITES TOTAL OF 2 AT BULK HEAD ROOF SKYLIGHT
2010-08-24HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2010-08-24HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT BULK HEAD AT PUBLIC HALL
2010-06-25Tenant complaint: HEATING — HEAT RELATED
2010-06-17311: HEATING — HEAT
2010-06-17311: PLUMBING — WATER-SUPPLY
2010-06-17311: HEATING — HEAT
2010-06-17Tenant complaint: HEATING — HEAT RELATED
2010-06-17Tenant complaint: PLUMBING — WATER SUPPLY
2010-06-17Tenant complaint: HEATING — HEAT RELATED
2010-06-16311: HEATING — HEAT
2010-06-16311: HEATING — HEAT
2010-06-16Tenant complaint: HEATING — HEAT RELATED
2010-06-16Tenant complaint: HEATING — HEAT RELATED
2010-06-10HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2010-06-09311: HEATING — HEAT
2010-06-09311: HEATING — HEAT
2010-06-09Tenant complaint: HEATING — HEAT RELATED
2010-06-09Tenant complaint: HEATING — HEAT RELATED
2010-06-08311: NONCONST — JANITOR-SUPER
2010-06-08311: HEATING — HEAT
2010-06-08311: NONCONST — RUBBISH
2010-06-08311: HEATING — HEAT
2010-06-08Tenant complaint: NONCONST — RUBBISH
2010-06-08Tenant complaint: HEATING — HEAT RELATED
2010-06-08Tenant complaint: HEATING — HEAT RELATED
2010-05-26HPD class B: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDEANCE OF A CONCEAL WATER LEAK OVER CEILING IN THE 1st BEDROOM FROM NOR
2010-05-26HPD class B: § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW A
2010-05-26HPD class A: § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISS
2010-05-26HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR (NOT INSTALLED) IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT
2010-05-26HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM WES
2010-05-26HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2010-05-26HPD class A: § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON
2010-05-26HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BOTTOM WOODEN SASH TO WINDOW BETWEEN 5TH AND 6TH STORYS AT PUBLIC HALL
2010-05-26HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL AND CEILING IN THE 1st BEDROOM F
2010-05-15HPD class A: § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM
2010-05-12311: HEATING — HEAT
2010-05-12Tenant complaint: HEATING — HEAT RELATED
2010-04-30DOB violation E:
2010-04-28311: HEATING — HEAT
2010-04-28Tenant complaint: HEATING — HEAT RELATED
2010-04-27311: GENERAL CONSTRUCTION — LOCKS
2010-04-27311: GENERAL CONSTRUCTION — DOORS
2010-04-27311: NONCONST — VERMIN
2010-04-27311: HEATING — HEAT
2010-04-27Tenant complaint: GENERAL — LOCKS
2010-04-27Tenant complaint: GENERAL — DOORS
2010-04-27Tenant complaint: NONCONST — VERMIN
2010-04-27Tenant complaint: HEATING — HEAT RELATED
2010-04-10311: PAINT - PLASTER — CEILING
2010-04-10311: PLUMBING — WATER-LEAKS
2010-04-10311: HEATING — HEAT
2010-04-10Tenant complaint: HEATING — HEAT RELATED
2010-04-07City emergency repair (OMO): replace with new the broken / defective marble tread # 1 from lobby to 1st floor public hall stairs remove all work rela$340
2010-03-31311: HEATING — HEAT
2010-03-31311: HEATING — HEAT
2010-03-31Tenant complaint: HEATING — HEAT RELATED
2010-03-31Tenant complaint: HEATING — HEAT RELATED
2010-03-30311: HEATING — HEAT-PLANT
2010-03-30311: HEATING — HEAT
2010-03-30Tenant complaint: HEATING — HEAT RELATED
2010-03-30Tenant complaint: HEATING — HEAT-PLANT
2010-03-28311: HEATING — HEAT
2010-03-28Tenant complaint: HEATING — HEAT RELATED
2010-03-26311: HEATING — HEAT
2010-03-26Tenant complaint: HEATING — HEAT RELATED
2010-03-26HPD class A: § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM
2010-03-26HPD class A: § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON
2010-03-26HPD class A: § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX ''MI
2010-03-26HPD class A: § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND
2010-03-26HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2010-03-25311: Elevator — Elevator - Defective/Not Working
2010-03-25311: HEATING — HEAT
2010-03-25Tenant complaint: HEATING — HEAT RELATED
2010-03-25DOB complaint, category ?
2010-03-24311: HEATING — HEAT
2010-03-24Tenant complaint: HEATING — HEAT RELATED
2010-03-18HPD class A: § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISS
2010-03-18HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 6D, 6th STORY, 2n
2010-03-18HPD class B: § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW A
2010-03-18HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM WES
2010-03-18HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL IN THE 1st ROOM FROM
2010-03-18HPD class A: § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM
2010-03-18HPD class A: § 27-2005 ADM CODE REFIT DOOR TO ROOF AT BULKHEAD AT PUBLIC HALL, 6th STORY
2010-03-18HPD class A: § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON
2010-03-18HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE FRAME INTERIOR TO DOOR EGRESS TO ROOF AT BULKHEAD AT PUBLIC HALL, 6th STORY
2010-03-18HPD class A: § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND
2010-03-18HPD class A: § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPE
2010-03-18HPD class C: § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING SLIDE BOLT WITH EYE ACCESSIBLE TO PAD LOCK ON DOOR EGRESS TO ROOF AT BULKHEAD AT PUBLI
2010-03-16Tenant complaint: HEATING — HEAT RELATED
2010-03-16Tenant complaint: HEATING — HEAT RELATED
2010-03-15311: Elevator — Elevator - Defective/Not Working
2010-03-15DOB complaint, category ?
2010-03-15ECB CLASS - 2 violation: 12Q3.01X10.16T7.56Y13.39O2.58E10.01X10 ALARM SYSYTEM FOR EMERGENCY STOP SWITCH IS INOPERATIVE 16 PROVIDE FL DESIGNATION NUMBERS B $500
2010-03-14311: CONSTRUCTION — ELEVATOR
2010-03-14311: HEATING — HEAT
2010-03-14311: CONSTRUCTION — ROOF
2010-03-14311: HEATING — HEAT
2010-03-14311: NONCONST — RUBBISH
2010-03-14Tenant complaint: HEATING — HEAT RELATED
2010-03-14Tenant complaint: CONSTRUCTION — ROOF
2010-03-14Tenant complaint: HEATING — HEAT RELATED
2010-03-14Tenant complaint: NONCONST — RUBBISH
2010-03-14Tenant complaint: CONSTRUCTION — ELEVATOR
2010-03-13311: HEATING — HEAT
2010-03-13Tenant complaint: HEATING — HEAT RELATED
2010-03-12311: HEATING — HEAT
2010-03-12Tenant complaint: HEATING — HEAT RELATED
2010-03-10311: HEATING — HEAT
2010-03-10Tenant complaint: HEATING — HEAT RELATED
2010-03-04311: Elevator — Elevator - Defective/Not Working
2010-01-05311: Sanitation Condition — 15 Street Cond/Dump-Out/Drop-Off
2010-01-04311: HEATING — HEAT
2010-01-04Tenant complaint: HEATING — HEAT RELATED
2009
2009-10-14Tenant complaint: GENERAL — DOORS
2009-10-14Tenant complaint: HEATING — HEAT RELATED
2009-10-14Tenant complaint: HEATING — HEAT RELATED
2009-10-14Tenant complaint: HEATING — HEAT RELATED
2009-10-14Tenant complaint: HEATING — HEAT RELATED
2009-10-13Tenant complaint: HEATING — HEAT RELATED
2008
2008-06-18DOB violation E:
2008-01-29ECB Non-Hazardous violation: 01X1.21J01.05L1.08V01.63U15.86M05.58Y10.40T07 01X10-IN CAR STOP SWITCHINOPERATIVE CEASE USE 21J01-ADJUST ALL HALL DOOR INTERLOCKS $800
2007
2007-10-24Job filed: INSTALL BOILER AND OIL BURNER. INSTALL A WEIL MCLAIN 9-80-S WITH A CARLIN 702 CRD. CHANGE GRADE OF OIL FROM #4 TO #2. NO CHANGE IN EGRESS, USE, OR OCC
2007-10-24Permit EW — ISSUED
2007-10-24Permit EW — ISSUED
2007-10-24Permit EW — ISSUED
2007-10-24Permit EW — ISSUED
2007-04-23Tenant complaint: HEATING — HEAT RELATED
2006
2006-12-13Mortgage assigned — from NEW YORK COMMUNITY BANK to ASTORIA FEDERAL SAVINGS AND LOAN ASSOCIA
2006-12-13AL&R $650,000 — from ASTORIA FEDERAL SAVINGS AND LOAN ASSOCIA to NALPANTIDIS, ESFTATHIOS$650,000
2006-12-13M&CON $650,000 — from NALPANTIDIS, ESFTATHIOS to ASTORIA FEDERAL SAVINGS AND LOAN ASSOCIA$650,000
1994-05-17HPD class C: § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTEPIPE WASHBASIN BATHROOM 5 STY EAST APT 5D ER1. , SECTION '' ''
1994-05-17HPD class C: § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT PEELING PAINT CEILING SOUTHEAST ROOM 5 STY
1994-05-17HPD class C: § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS KITCHEN SINK AND BATHTUB BATHROOM 5 STY EAST APT 5D ER1. , SECTION '' ''
1993
1993-02-24ECB Non-Hazardous violation: 01B, (01) REPLACE CONSTANT PRESSURE TYPE STOP SWITCH WITH STOP/RUN TYPE AND LABEL