The city's published records show little recorded distress here in the last three years. Less recorded distress than 58% of 25-99-unit residential buildings citywide. The citywide median for 25-99-unit residential buildings is 23.6 penalty
points per 10 units; this building carries 15.4. In ZIP 11375, 92% of residential buildings hold an A and
1% grade D or F.
How grades work
this building
A
B
C
Among 17,252 25-99-unit residential buildings citywide · left is less recorded distress, right is more
Open with the city right now
Open HPD violations
13 total — 4 class C (immediately hazardous), 6 class B, 3 class A. Oldest open since 1995-05-15.
status snapshot refreshed weekly from HPD records
Patterns
4 heat or hot-water complaints in the last three years (winter 2024–25: 2 · winter 2025–26: 2). Repeated winter clusters suggest a chronic heating problem.
2
’24–25
2
’25–26
No bedbug-infested units reported in the last three years of filings.
$6,250 in enforcement penalties imposed (ECB/OATH) in the last three years.
What 311 hears from this address
40 service requests in the last three years. Most common: Lead (7) · Abandoned Vehicle (6) · Noise (5) · Missed Collection (5) · Illegal Parking (3) · Elevator (2).
Filed construction activity
$213,500 in permitted construction work filed since
2016 (8 filings with a declared cost) — a rough measure of how actively
the owner maintains the building. Permit costs cover filed construction work only — they do not
capture routine maintenance or repairs done without a permit.
Rent-stabilization signals
Yes
Built before 1974 (1929)
Yes
Six or more residential units (72)
No
421-a / J-51 tax benefit on the current tax roll
2 of 3 signals present. This is the classic profile of a rent-stabilized building (pre-1974, 6+ units) — many units in such buildings remain stabilized. The definitive answer for any unit:
request its rent history from NYS Homes & Community Renewal (free, at hcr.ny.gov).
Registered with HPD — the names behind the building
Registered owner(s)
771620 EQUITIES CORP
Head officer
JAMES DEMETRIOU
Managing agent
FIRST MANAGEMENT CORP
Last registered
2025-09-25
as filed by the owner in the building's HPD registration
What the city thinks it's worth
Tax year
City market value
Assessed value
2025
$6,655,000
$2,994,750
2026
$6,494,000
$2,922,300
2027
$7,358,000
$3,311,100
The city's market estimate has risen
11% between tax years 2025 and 2027.
Tax exemptions on the roll: COLD WAR VETERAN - DISABILITY
For property tax, the Department of Finance values this co-op
as if it were a rental building. Its 2022 estimate: gross income $1,550,490 a year
($20.22 per sq ft), operating expenses $687,829
($8.97 per sq ft), net operating income $862,661. These are the
city's estimates from comparable rentals, not the building's actual budget, rents or maintenance
charges.
Building systems
Energy grade (LL33)
B — ENERGY STAR score 81/100 (2022 disclosure cycle)
Heating fuel
NATURALGAS
Flood exposure
Not in the FEMA 1%-annual-chance floodplain (2015 preliminary maps).
Not in a hurricane evacuation zone.
Not in the city's stormwater (cloudburst) flood maps under any modeled scenario.
1 street-flooding or sewer-backup complaints at this address since
2010 (0 in the last three years).
Sources: FEMA flood maps (coastal), NYC DEP Stormwater Flood Maps
(cloudburst), NYC hurricane evacuation zones, and 311 records for this address.
Getting around
Subway
Kew Gardens-Union Tpke — E F · 900 ft straight-line (about a 4-minute walk) · station accessibility: full
Bus
Nearest boarding stop: Union Tpke / Grenfell St — Q37 · 700 ft
Citi Bike
78 Ave & Queens Blvd S · 850 ft · station location as of 2026-09-23; live availability
Distances are straight-line, not walking routes. Transit locations from the MTA and
Citi Bike, bike facilities from NYC DOT, school zones from the DOE's 2024–25 maps.
40 311 service requests from this address in the last three years — 2 of them about heat or hot water.
311 will ask for the address, the apartment if the problem is inside, and what's wrong.
Contact details are optional for most complaints; food-poisoning reports can be anonymous. Complaints
appear in the city's public 311 data, usually within a day or two, and then in the Live from 311 box
on this page.
Most recent mortgage recorded against this lot: $400,000 on
2022-06-17 (lender: Valley National Bank). Face amount at recording — it may have since been paid
down, refinanced or satisfied. View the recorded
document.
Date
Record
Amount
Per res. unit
2026-03-26
RPTT&RET $750,000 — from STRATEGIC ACQUISITION GROUP, INC. to KANG, DANIEL; KANG, EVITA VICTORIA
$750,000
2026-03-11
Sold for $750,000
$750,000
$10,417
2026-01-16
RPTT&RET $460,000 — from BARRUNDIA, ANNELISSE to HOWLEY, ERIN MARIE
$460,000
2026-01-14
Sold for $460,000
$460,000
$6,389
2025-09-18
RPTT&RET $310,000 — from STOFFEL, DAVID to ROSENTHAL, KRITHIKA C; ROSENTHAL, GALEN U
$310,000
2025-09-16
Sold for $310,000
$310,000
$4,306
2025-07-18
RPTT&RET $226,600 — from GILLIGAN, CHRISTOPHER to GONZALEZ, THERESA M; INGENITO, PAIGE; GONZALEZ, ISRAEL
$226,600
2025-06-26
Sold for $226,600
$226,600
$3,147
2024-12-23
RPTT&RET $445,000 — from MEJIA, SERENA D to DIGRAZIA, DANIELLE M; TOBIN, BRITTANY D
$445,000
2024-12-12
Sold for $445,000
$445,000
$6,181
2024-10-02
RPTT&RET $239,000 — from ROSAL, MATTHEW to MCLAUGHLIN, CARLEEN
$239,000
2024-08-13
RPTT&RET $260,000 — from KIM, CARY to SHAKYA, PEMA TSOKYE; TSERING, TASHI
$260,000
2024-08-07
Sold for $239,000
$239,000
$3,319
2024-07-31
Sold for $260,000
$260,000
$3,611
2024-07-03
RPTT&RET $415,000 — from ZERWES, VALQUIRIA INES CHIARION; ZERWES, EDUARDO BOS to HANNIGAN, JOHN THOMAS
$415,000
Ten-year activity
100500
2017
51
2018
2019
2020
2021
2022
2023
2024
2025
2026
ConstructionEnforcementHousing & tenantsOwnership & moneyHealth & systems
Show as table
Year
Construction
Enforcement
Housing & tenants
Ownership & money
Health & systems
Total
2017
0
2
5
6
0
13
2018
0
3
34
12
2
51
2019
2
0
13
6
2
23
2020
0
6
1
4
2
13
2021
7
6
8
10
1
32
2022
8
1
19
12
2
42
2023
0
6
10
5
2
23
2024
0
2
22
8
2
34
2025
0
2
16
4
1
23
2026
0
1
25
4
3
33
This record is free. Keeping it free costs money. Servers, data pipelines, weekends. Pay what you want — a dollar helps.
311: General Construction/Plumbing — Debris - Excessive
2026-08-19
DOB complaint, category ?
2026-08-13
Tenant complaint: ELECTRIC — WIRING
2026-08-13
Tenant complaint: UNSANITARY CONDITION — PESTS
2026-08-13
311: ELECTRIC — WIRING
2026-08-13
311: UNSANITARY CONDITION — PESTS
2026-08-11
Tenant complaint: UNSANITARY CONDITION — PESTS
2026-08-11
311: UNSANITARY CONDITION — PESTS
2026-07-29
311: Unsanitary Animal Pvt Property — Cat
2026-07-29
311: Indoor Air Quality — Ventilation
2026-07-24
Rodent inspection: Failed for Rat Activity and Other Reason
2026-07-18
311: Rodent — Condition Attracting Rodents
2026-07-03
311: Missed Collection — Compost
2026-06-13
311: Panhandling — N/A
2026-05-18
City emergency repair (OMO): #1: hopper door, 4th story.. #2: compactor closet door latch, 4th story. #3: compactor closet door latch, 1st story. #1:
2026-04-03
HPD class B: § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVI
2026-04-03
HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-04-03
HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 4D, 4th STOR
2026-04-03
HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2026-04-03
HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-04-03
HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-04-03
HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS AND CEILING IN THE KITCHEN LO
2026-03-26
RPTT&RET $750,000 — from STRATEGIC ACQUISITION GROUP, INC. to KANG, DANIEL; KANG, EVITA VICTORIA
2026-03-19
Tenant complaint: WATER LEAK — SLOW LEAK
2026-03-19
311: WATER LEAK — SLOW LEAK
2026-03-11
Sold for $750,000
2026-01-30
Bedbug filing: 0 infested units
2026-01-21
311: Abandoned Vehicle — With License Plate
2026-01-16
RPTT&RET $460,000 — from BARRUNDIA, ANNELISSE to HOWLEY, ERIN MARIE
2026-01-14
Sold for $460,000
2026-01-09
Boiler inspection
2025-12-12
311: Missed Collection — Compost
2025-12-12
311: Missed Collection — Compost
2025-12-09
Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2026-04-03HPD class B: § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVI
2026-04-03HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-04-03HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 4D, 4th STOR
2026-04-03HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2026-04-03HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-04-03HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-04-03HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS AND CEILING IN THE KITCHEN LO
2026-03-26RPTT&RET $750,000 — from STRATEGIC ACQUISITION GROUP, INC. to KANG, DANIEL; KANG, EVITA VICTORIA$750,000
2026-03-19Tenant complaint: WATER LEAK — SLOW LEAK
2026-03-19311: WATER LEAK — SLOW LEAK
2026-03-11Sold for $750,000$750,000
2026-01-30Bedbug filing: 0 infested units
2026-01-21311: Abandoned Vehicle — With License Plate
2026-01-16RPTT&RET $460,000 — from BARRUNDIA, ANNELISSE to HOWLEY, ERIN MARIE$460,000
2026-01-14Sold for $460,000$460,000
2026-01-09Boiler inspection
2025
2025-12-12311: Missed Collection — Compost
2025-12-12311: Missed Collection — Compost
2025-12-09Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2025-12-09311: HEAT/HOT WATER — ENTIRE BUILDING
2025-09-18RPTT&RET $310,000 — from STOFFEL, DAVID to ROSENTHAL, KRITHIKA C; ROSENTHAL, GALEN U$310,000
2025-03-01311: Noise — Noise: Construction Before/After Hours (NM1)
2025-01-29Bedbug filing: 0 infested units
2025-01-25311: Lead — Lead Kit Request (Residential) (L10)
2025-01-19311: Lead — Lead Kit Request (Residential) (L10)
2024
2024-12-26Elevator permit: Modernization of device 4P513 and 4P514. All work to comply with Safety Code for Elevators and Escalators ASME A17.1-2013, Part 8,$110,000
2024-12-23RPTT&RET $445,000 — from MEJIA, SERENA D to DIGRAZIA, DANIELLE M; TOBIN, BRITTANY D$445,000
2024-12-15Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2024-12-15311: HEAT/HOT WATER — ENTIRE BUILDING
2024-12-12Sold for $445,000$445,000
2024-11-27311: Lead — Lead Kit Request (Residential) (L10)
2024-10-02RPTT&RET $239,000 — from ROSAL, MATTHEW to MCLAUGHLIN, CARLEEN$239,000
2024-08-13RPTT&RET $260,000 — from KIM, CARY to SHAKYA, PEMA TSOKYE; TSERING, TASHI$260,000
2024-08-07Sold for $239,000$239,000
2024-07-31Sold for $260,000$260,000
2024-07-03RPTT&RET $415,000 — from ZERWES, VALQUIRIA INES CHIARION; ZERWES, EDUARDO BOS to HANNIGAN, JOHN THOMAS$415,000
2024-06-23311: Lead — Lead Kit Request (Residential) (L10)
2024-06-17Sold for $415,000$415,000
2024-06-06HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM N
2024-06-06HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY,
2024-06-06HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2024-06-06HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM N
2024-06-06HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2024-06-06HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2024-06-06HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2024-06-06HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2024-06-06HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY,
2024-06-06HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2024-05-07311: Lead — Lead Kit Request (Residential) (L10)
2024-01-08ECB CLASS - 1 violation: DLM NOT WORKING. REPAIR. PHONE NOT WORKING. REPAIR. PROVIDE RUN BY SIGN IN PIT.$6,250
2024-01-06311: Abandoned Vehicle — With License Plate
2024-01-06311: Abandoned Vehicle — With License Plate
2023
2023-12-18311: Abandoned Vehicle — With License Plate
2023-12-16311: Abandoned Vehicle — With License Plate
2023-12-04RPTT&RET $237,000 — from BARNAVE, LEA NOELLE to UNGAR, OLIVIA V; UNGAR, GYOZO DAVID$237,000
2023-11-24HPD class I: §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE
2023-11-20311: Abandoned Vehicle — With License Plate
2023-11-16Sold for $237,000$237,000
2023-10-30RPTT&RET $255,000 — from CACCAMO, JASMINE; CACCAMO, JOSEPH to TALAMPAS, MARIA ANNE$255,000
2023-10-25311: Elevator — Elevator - Multiple Devices On Property
2023-10-25DOB complaint, category ?
2023-10-16Air permit (CERTIFICATE TO OPERATE), fuel: NATURALGAS
2023-10-13311: Abandoned Vehicle — With License Plate
2023-08-17RPTT&RET $235,000 — from CULLARI, MARIA TERESA to SZETO, CONNIE GAGA$235,000
2023-07-01311: Elevator — Elevator - Single Device On Property/No Alternate Service
2023-07-01DOB complaint, category ?
2023-06-26ECB CLASS - 1 violation: NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER$3,125
2023-05-26311: Lead — Lead Kit Request (Residential) (L10)
2023-05-26DOB complaint, category ?
2023-05-24311: Elevator — Elevator - Single Device On Property/No Alternate Service
2022-04-15RPTT&RET $310,000 — from MARK, MARY to ALEMAN, HUGO$310,000
2022-04-06Job filed: REPLACEMENT OF NEW WASHERS & DRYERS, INSTALLATION OF 2 NEW SPRINKLER HEADS AT CELLAR LEVEL AS SHOWN ON PLANS. THERE IS NO CHANGE IN USE, OCCUPANCY OR $6,500
2022-03-07Job filed: HEREWITH FILE TO RENOVATE EXIST. UNIT #2C. WORK INCLUDES NEW NON-LOAD BEARING WALL, NEW PAINT, NEW FLOORING, NEW/RELOCATE PLUMBING FIXTURES, AND GENER$78,500
2022-03-07Job filed: HEREWITH FILE TO RENOVATE EXIST. UNIT #2C. WORK INCLUDES NEW NON-LOAD BEARING WALL, NEW PAINT, NEW FLOORING, NEW/RELOCATE PLUMBING FIXTURES, AND GENER$16,000
2022-03-04HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2022-03-03Bedbug filing: 0 infested units
2022-03-02311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2022-02-24311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2022-02-23Job filed: REPLACEMENT OF NEW WASHERS & DRYERS, INSTALLATION OF 2 NEW SPRINKLER HEADS AT CELLAR LEVEL AS SHOWN ON PLANS. THERE IS NO CHANGE IN USE, OCCUPANCY OR $6,500
2022-02-16Permit General Construction — Signed-off
2022-02-14311: Noise — Noise: Construction Equipment (NC1)
2022-01-11Permit General Construction — Signed-off
2022-01-11Permit Mechanical Systems — Signed-off
2021
2021-12-22DOB violation AEUHAZ1: FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2021-12-22DOB violation AEUHAZ1: FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2021-12-16311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2021-12-06FDNY inspection (RISK)
2021-12-05311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2021-11-10Permit Plumbing — Signed-off
2021-11-09311: Damaged Tree — Branch Cracked and Will Fall
2021-11-02Permit General Construction — Signed-off
2021-10-26RPTT&RET $299,000 — from LE, CARSON MINH to HWANG, MINHEE$299,000
2021-10-20Permit General Construction — Signed-off
2021-10-14Sold for $299,000$299,000
2021-10-05Job filed: HEREWITH FILE TO RENOVATE EXIST. UNIT #2C. WORK INCLUDES NEW NON-LOAD BEARING WALL, NEW PAINT, NEW FLOORING, NEW/RELOCATE PLUMBING FIXTURES, AND GENER$78,500
2021-10-05Job filed: HEREWITH FILE TO RENOVATE EXIST. UNIT #2C. WORK INCLUDES NEW NON-LOAD BEARING WALL, NEW PAINT, NEW FLOORING, NEW/RELOCATE PLUMBING FIXTURES, AND GENER$16,000
2021-09-10Job filed: Alteration
2021-09-10Job filed: REPLACEMENT OF NEW WASHERS & DRYERS, INSTALLATION OF 2 NEW SPRINKLER HEADS AT CELLAR LEVEL AS SHOWN ON PLANS. THERE IS NO CHANGE IN USE, OCCUPANCY OR $6,500
2021-09-09ECB CLASS - 1 violation: DLM IMPROPERLY INSTALLED ON THIS DEVICE NO FIREMAN SERVICE PRESENT IN CONTROLLER INSTALL FIREMAN SERVICE SO DLM IS IN COMPLIANCE W$1,250
2021-09-09ECB CLASS - 1 violation: D.L.M. IMPROPERLY INSTALLED ON THIS DEVICE NO FIREMAN SERVICE PRESENT IN CONTROLLER INSTALL FIREMAN SERVICE SO DLM IS IN COMPLIANC$1,250
2021-09-09DOB complaint, category ?
2021-08-09311: Noise — Noise: Jack Hammering (NC2)
2021-08-05RPTT&RET $215,000 — from ZHOU, SU to TUY, LILYBETH; TUY, MIKHAIL$215,000
2021-07-31311: Noise — Noise: Construction Equipment (NC1)
2021-07-14Sold for $215,000$215,000
2021-06-24RPTT&RET $454,000 — from JIMENEZ, PABLO; NEUMANN-REDLIN, ADRIANA to CHUANG, HUI CHI; KU, ERIC$454,000
2021-06-15Sold for $454,000$454,000
2021-05-25311: Noise - Vehicle — Car/Truck Music
2021-05-10RPTT&RET $257,000 — from HENRY, ERIN K; GALLO, JAMES to STOFFEL, DAVID R$257,000
2021-05-02311: Dead/Dying Tree — Planted More Than 2 Years Ago
2021-04-12Sold for $257,000$257,000
2021-04-08RPTT&RET $299,000 — from SIU, HENRY; SIU, TING to PETERSON, MARYANN LOKELANI$299,000
2021-04-08Bedbug filing: 0 infested units
2021-03-11Sold for $299,000$299,000
2021-01-15Boiler inspection
2020
2020-11-25DOB violation AEUHAZ1: FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2020-08-27ECB CLASS - 2 violation: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.2; 27-95$1,250
2020-08-27ECB CLASS - 1 violation: WORK WITHOUT PERMIT. AT TIME OF INSPECTION IN LAUNDRY ROOM I OBSERVED 4 NEW GAS DRYERS. NO PERMIT ON DOB RECORDS TO PERFORM THIS W$2,500
2020-08-20DOB complaint, category ?
2020-06-24Elevator permit: FURNISH AND INSTALL NEW DOOR LOCKS 2.12.6. AS PER OPPN 26/90.$5,000
2020-04-24311: Request Large Bulky Item Collection — Request Large Bulky Item Collection
2020-03-09FDNY inspection (RISK)
2020-03-09FDNY inspection (RISK)
2020-03-02RPTT&RET $440,000 — from ERDELYI, TIBOR to O'NEIL, CASEY; DWOSKIN, LILY ANNA$440,000
2020-02-26Sold for $440,000$440,000
2020-02-06RPTT&RET $280,000 — from ROSAL, STEPHANY M to DAVI, ANTONINO$280,000
2020-01-23Sold for $280,000$280,000
2020-01-06Boiler inspection
2019
2019-12-30Elevator permit: Furnish and install new interface control board and updated software for 2020 Lock monitoring Compliance under ASME A17.3 of 2002,$5,000
2019-10-22RPTT&RET $225,000 — from BELL, ROGER to ROSAL, MATTHEW$225,000
2019-10-16HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1A, 1st STO
2019-10-16HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT
2019-10-09RPTT&RET $450,000 — from RIVAS, ANDREINA BEATRIZ; PEINADO, ULISES NERY to MEJIA, SERENA D$450,000
2019-10-08Tenant complaint: WATER LEAK — HEAVY FLOW
2019-10-08311: WATER LEAK — HEAVY FLOW
2019-10-04Sold for $225,000$225,000
2019-10-02Sold for $450,000$450,000
2019-09-24RPTT&RET $275,000 — from NAYLOR, JEREMY to MONCINO, JENNIFER CATHERINE$275,000
2019-07-23Job filed: PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE $5,000
2019-03-14HPD class B: § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 6H, 6th STORY, 2nd APARTMENT FROM NORTH A
2019-03-05Boiler inspection
2019-03-03311: Street Light Condition — Street Light Out
2019-02-05311: Water System — Leak (Use Comments) (WA2)
2019-01-24311: Homeless Person Assistance
2018
2018-11-13RPTT&RET $270,000 — from CHAN, KAYEE to CURRAN, EILEEN M$270,000
2018-11-06311: Noise - Residential — Loud Television
2018-10-31311: Noise - Helicopter — Other
2018-10-24Sold for $270,000$270,000
2018-09-16311: New Tree Request — For One Address
2018-08-31RPTT&RET $290,000 — from MEWENGKANG, ANDHIKA R to BARTOLOMEO, ASHLEY$290,000
2018-08-21Sold for $290,000$290,000
2018-07-25RPTT&RET $259,000 — from SCHWARZ, JUNE; SCHWARZ, JACK; SCHWARZ, WILLIAM to MINH LE, CARSON$259,000
2018-07-20RPTT&RET $185,000 — from LERER, MARK to ZHOU, SU$185,000
2018-07-16Sold for $259,000$259,000
2018-07-12Sold for $185,000$185,000
2018-05-24RPTT&RET $250,000 — from MCLOUGHLIN, MARGARET S to BARNAVE, LEA NOELLE$250,000
2018-05-16Sold for $250,000$250,000
2018-05-15Rodent inspection: Failed for Other Reason
2018-05-03HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE GFI ELECTRIC OUTLET AT WEST WALL IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 2nd
2018-05-03HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN SURFACE AT THE INTERIOR AT BATHTUB (REGLAZE) IN T
2018-05-03HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALLS INSIDE CABINETS IN THE KITC
2018-05-03HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FLOOR VINYL COVER IN THE KITCHEN LOCATED AT APT 3A, 3rd STO
2018-05-03HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT
2018-05-03HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE NORTH WALL CERAMIC TILES IN THE BATHROOM LOCATED AT APT 3A,
2018-05-03HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE PRIVATE HALLWAY LOCATED
2018-05-03HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH LOC
2018-05-03HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH AT
2018-05-03HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL JAMB AND INTERIOR WOOD TRIMMING IN THE ENTRANCE LOCAT
2018-04-05HPD class A: § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGE
2016-03-29RPTT&RET $170,000 — from AKHUNOV, SIMKHO to MALLIAROS, ALYKI$170,000
2016-03-22Sold for $170,000$170,000
2016-03-17RPTT&RET $365,000 — from CHANG, DANIEL to KAU, SANDY; KAU, JERRY$365,000
2016-03-15RPTT&RET $146,000 — from SULLIVAN, JANE C to CULLARI, MARIA TERESA$146,000
2016-03-14HPD class B: SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL SWITCH AT EAST WALL IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY
2016-03-14HPD class B: SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY
2016-03-14HPD class B: SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY
2016-03-14HPD class B: SECTION 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE PRIVATE HALLWAY LOCATED
2016-03-14HPD class B: SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL SWITCH AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3A, 3
2016-03-14HPD class A: SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT FLOOR IN THE KITCHEN LOCATED AT APT 3
2016-03-09Sold for $365,000$365,000
2016-03-03Tenant complaint: ELECTRIC — NO LIGHTING
2016-03-03Tenant complaint: ELECTRIC — OUTLET/SWITCH
2016-03-03Tenant complaint: ELECTRIC — OUTLET/SWITCH
2016-03-03Tenant complaint: ELECTRIC — OUTLET/SWITCH
2016-03-03Tenant complaint: ELECTRIC — OUTLET/SWITCH
2016-03-03Tenant complaint: ELECTRIC — NO LIGHTING
2016-03-03311: ELECTRIC — OUTLET/SWITCH
2016-03-03311: ELECTRIC — OUTLET/SWITCH
2016-03-03311: ELECTRIC — OUTLET/SWITCH
2016-03-03311: ELECTRIC — NO LIGHTING
2016-03-03311: ELECTRIC — OUTLET/SWITCH
2016-03-03311: ELECTRIC — NO LIGHTING
2016-02-26RPTT&RET $175,000 — from DE CASTRO, CESAR to ROSAL, STEPHANY$175,000
2016-02-26Tenant complaint: ELECTRIC — NO LIGHTING
2016-02-26Tenant complaint: ELECTRIC — OUTLET/SWITCH
2016-02-26Tenant complaint: ELECTRIC — OUTLET/SWITCH
2016-02-26Tenant complaint: ELECTRIC — OUTLET/SWITCH
2016-02-26Tenant complaint: ELECTRIC — OUTLET/SWITCH
2016-02-26311: ELECTRIC — OUTLET/SWITCH
2016-02-26311: ELECTRIC — NO LIGHTING
2016-02-26311: ELECTRIC — OUTLET/SWITCH
2016-02-26311: ELECTRIC — OUTLET/SWITCH
2016-02-26311: ELECTRIC — OUTLET/SWITCH
2016-02-18Sold for $146,000$146,000
2016-02-04Sold for $175,000$175,000
2016-01-21RPTT&RET $154,000 — from NUSSBAUM , MARGARET to DOLECKA , DANUTA; DOLECKI , JOZEF$154,000
2016-01-07Sold for $154,000$154,000
2015
2015-12-02HPD class B: § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ELECTRIC CEILING LIGHT FIXTURE, IN THE 1st ROOM
2015-12-02HPD class B: § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ELECTRIC CEILING LIGHT FIXTURE & OUTLET, IN THE
2015-12-01Tenant complaint: ELECTRIC — OUTLET/SWITCH
2015-11-30RPTT&RET $375,000 — from ZHANG, WINNIE; WONG , WINNIE to JIMENEZ , PABLO; NEUMANN-REDLIN , ADRIANA$375,000
2015-10-20RPTT $173,500 — from BARON, MICHAEL to NAYLOR, JEREMY$173,500
2015-10-20Tenant complaint: ELECTRIC — OUTLET/SWITCH
2015-10-20311: ELECTRIC — OUTLET/SWITCH
2015-10-16HPD class I: SECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE ?27-2097 AND IS THER
2015-08-11RPTT&RET $175,000 — from SISCOE, GABRIELLE V; LAMELZA, GABRIELLE V to CHAN, KAYEE$175,000
2013-06-03311: Lead — Lead Kit Request (Residential) (L10)
2013-05-13311: Construction — Re-Inspect - No Show
2013-04-29311: Construction — Initial - Construction
2013-04-19311: Indoor Air Quality — Dry Cleaning Vapors (PERC)
2013-03-29Permit PL — ISSUED
2013-03-01DOB violation LBLVIO: VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
2013-01-10HPD class A: SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOUTH WALL AT PUBLIC HALL,
2013-01-10HPD class A: SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT EAST WALL AROUND ENTRANCE DOOR TO VESTIBULE A
2012-11-19Job filed: HEREWITH FILE TO RENOVATE EXISTING APARTMENT UNIT #3G INCLUDES INSTALL G.W.B. WALL, PAINT, K. CABINET, REPLACE PLUMBING FIXTURE, DOORS AND GENERAL CON$40,500
2012-11-19Job filed: HEREWITH FILE TO RENOVATE EXISTING APARTMENT UNIT #3G INCLUDES INSTALL G.W.B. WALL, PAINT, K. CABINET, REPLACE PLUMBING FIXTURE, DOORS AND GENERAL CON$40,500
2012-11-08DOB violation E:
2012-11-08DOB violation E:
2012-08-15DOB violation E:
2012-07-13TL&R — from FANNIE MAC to 771620 EQUITIES CORP.
2012-07-06Mortgage assigned — from FANNIE MAE to SOVEREIGN BANK, N.A.
2012-07-06Mortgage $100,000 — from 771620 EQUITIES CORP. to SOVEREIGN BANK, N.A.$100,000
2012-07-06Agreement $3,100,000 — from 771620 EQUITIES CORP. to SOVEREIGN BANK, N.A.$3,100,000
2012-05-03DOB violation BENCH: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
2012-02-06RPTT&RET — from LENI I. BROADHURST, ADMINISTRATOR; THE ESTATE OF DENISE J. BROADHURST to BROADHURST, JOHN H; BROADHURST, LENI I
2011
2011-10-06DOB violation E:
2011-10-06DOB violation E:
2011-08-10RPTT&RET $165,000 — from STIDOLPH, MARIA to KIM, CARY$165,000
2011-07-25311: Illegal Parking — Blocked Sidewalk
2011-04-08311: Street Light Condition — Street Light Out
2011-03-04311: Water System — Hydrant Defective (WC2)
2011-02-18RPTT&RET $315,000 — from FERRO, AMY; FERRO, MARIO to MURPHY, MEREDITH; HOWLEY, ANTHONY$315,000
2010
2010-12-01RPTT&RET $10,000 — from KLEIN, RUDIGER; MORENO, AMELIA to MORENO, AMELIA$10,000
2010-11-25311: Root/Sewer/Sidewalk Condition — Affecting Sewer or Foundation
2010-11-12DOB violation E:
2010-11-12DOB violation E:
2010-11-10311: Lead — Lead Kit Request (Residential) (L10)
2008-02-11Tenant complaint: HEATING — HEAT RELATED
2008-01-31RPTT&RET $212,000 — from BATTISTA, NANCY to SCHWARZ, JACK; SCHWARZ, WILLIAM; SCHWARZ, JUNE$212,000
2007
2007-11-30RPTT&RET $190,000 — from ARENAS, ADRIENNE; ARENAS, JOSE to GELFAND, MICHAEL$190,000
2007-11-28RPTT&RET $267,500 — from WEISSMAN PROPERTIES, LLC. to BATTISTA, NANCY$267,500
2007-07-26RPTT&RET $325,000 — from D'AGATE, DAVID; EPSTEIN-D'AGATE, JENNIFER to BACHVAROV, BOZHIDAR; MONOVA-BACHVAROV, MARIANNA$325,000
2007-06-18RPTT&RET $305,000 — from STRATEGIC ACQUISITION GROUP, INC. to USOVIA, VICTORIA; KLEPATCH, ARKADI$305,000
2007-05-14DOB violation E:
2007-05-14DOB violation E:
2007-04-23Job filed: PROPOSED INSTALLATION OF 16 FEET X 60 FEET HIGH PIPE SCAFFOLD STAIR TOWER FOR RMEDIAL REPAIRS. SIDEWALK SHED FILED UNDER SEPARATE APPLICATION. NO CHAN
2007-04-23Permit EQ — ISSUED
2007-04-20Job filed: PROPOSED INSTALLATION OF 16 LINEAR FEET OF HEAVY DUTY SIDEWALK SHED FOR REMEDIAL REPAIRS. SIDEWALK SHED SHALL COMPLY WITH LL 33/91 & TPPN 9/1999.
2007-04-05RPTT&RET $300,000 — from SCHNEIDMAN, SHIRA; SCHNEIDMAN, SCOTT to FERRI, ANGELO; ARBASETTI, KAREN M$300,000
2007-01-29Permit PL — ISSUED
2006
2006-12-28RPTT&RET $420,000 — from KAKOSIAN, KENN to AUGSPACH, HEATHER; AUGSPACH, FRANCISCO$420,000
2006-12-14ECB Non-Hazardous violation: 86M05.86M05 CURRENT 2 YEAR TEST TAG IS MISSING$2,500
2006-11-09Permit EW — ISSUED
2006-10-30Mortgage assigned — from SOVEREIGN BANK to FANNIE MAE
2006-10-30AALR — from SOVEREIGN BANK to FANNIE MAE
2006-08-03Job filed: General construction including drywall partitions and plumbing revisions on the 4th floor. No change to occupancy, use or egress.$10,000
2006-08-02DOB violation E:
2006-08-02DOB violation E:
2006-07-18RPTT&RET $202,500 — from ALARCON, GUSTAVO; ALARCON , BEATRIZ ELENA to CACCAMO, JASMINE; CACCAMO, JOSEPH$202,500
2006-04-06Permit EQ — ISSUED
2006-03-13RPTT&RET $280,000 — from COSTELLO, ALISON; COSTELLO, ROBERT to TSE, CHOIFUN AUYEUNG; TSE, ANDREW CHI YIN$280,000
2006-02-16RPTT&RET $350,000 — from SZATHMARY, GABRIELLA to ZARDONI-CAUQUIL, LAETITIA; ZARDONI, OLIVIER$350,000
2006-01-31Permit EQ — ISSUED
2006-01-24Tenant complaint: PLUMBING — BASIN/SINK
2006-01-24Tenant complaint: GENERAL — FLOOR
2006-01-17RPTT&RET $270,000 — from Y&S DEVELOPMENT, INC. to ALARCON, GUSTAVO; ALARCON, BEATRIZ ELENA$270,000
2006-01-03Permit EQ — ISSUED
2005
2005-11-14RPTT&RET — from BROADHURST, DENISE; GRIFFIN, CHARLES to BROADHURST, DENISE
2005-11-01DOB violation E:
2005-11-01DOB violation E:
2005-10-19RPTT&RET $185,000 — from MARTIN, NATACHA to SISCOE, GABRIELLE VERONICA$185,000
2005-09-27Permit EW — ISSUED
2005-09-23Job filed: Installation of heavy duty sidewalk shed 300 ft long and 60 ft high at 77-16 -77-20 Austin Street.- during remedial repairs. Work shall comply with LL
2005-09-23Job filed: Installation of heavy duty sidewalk shed 300 ft long and 60 ft high at 77-16 -77-20 Austin Street.- during remedial repairs. Work shall comply with LL
2005-09-23Permit EQ — ISSUED
2005-09-22Job filed: Removal/replacement of existing roofing system and roof level masonry and steel repair/refurbishment at 77-16 & 77-20 Austin Street. NO CHANGE IN $311,000
2005-09-22Job filed: Removal/replacement of existing roofing system and roof level masonry and steel repair/refurbishment at 77-16 & 77-20 Austin Street. NO CHANGE IN $311,000
2005-09-15RPTT&RET $168,500 — from MAJOR, JAMES to ENG, NATHANIEL; ENG, HOWARD$168,500
2005-09-09Job filed: Installation of heavy duty sidewalk shed 200 ft and 20 ft at side entrance and 60 ft at main entrance for a tatal of 280 ft long at 77-16 -77-20 Austi
2005-09-09Job filed: Installation of heavy duty sidewalk shed 200 ft and 20 ft at side entrance and 60 ft at main entrance for a tatal of 280 ft long at 77-16 -77-20 Austi
2005-09-09Permit EQ — ISSUED
2005-09-02Job filed: Installation of heavy duty sidewalk shed 200 ft and 20 ft at side entrance and 60 ft at main entrance for a total of 280 ft long at 77-16 - 77-20 Aust
2005-09-02Job filed: Installation of heavy duty sidewalk shed 200 ft and 20 ft at side entrance and 60 ft at main entrance for a total of 280 ft long at 77-16 - 77-20 Aust
2005-09-02Permit EQ — ISSUED
2005-08-26RPTT&RET $150,000 — from ROBINSON, HEATHER A to ARENAS, ADRIENNE; ARENAS, JOSE$150,000
2005-08-24Mortgage assigned — from NEW YORK COMMUNITY BANK; QUEENS COUNTY SAVINGS BANK to INDEPENDENCE COMMUNITY BANK
2005-08-24AL&R $3,000,000 — from INDEPENDENCE COMMUNITY BANK to 771620 EQUITIES CORP$3,000,000
2005-08-24Agreement $3,000,000 — from 771620 EQUITIES CORP to INDEPENDENCE COMMUNITY BANK$3,000,000
2005-08-09RPTT $43,500 — from WEISSMAN PROPERTIES, LLC to BELL, ROGER$43,500
2005-07-25RPTT&RET $300,000 — from RAINES, LUZ to CHANG, DANIEL$300,000
2005-06-01Mortgage $833,147 — from 771620 EQUITY CORP to INDEPENDENCE COMMUNITY BANK$833,147
2005-01-28City emergency repair (OMO): local law #1 violation : as per rc #20050021129 (abax bk-w,si) and attached scope of work thoroughly remove all lead vio$930
2004-12-08HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR , WEST WALL, EAST WALL, NORTH WALL IN THE
2004-12-08HPD class C: § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIO
2004-08-16RPTT $130,000 — from Y&S DEVELOPMENT INC. to KLEIN, RUDIGER$130,000
2003
2003-07-18Permit EQ — RE-ISSUED
2003-07-11Job filed: INSTALLATION OF A HEAVY DUTY SIDEWALK SHED 40' DURING MASONRY REPAIR (EMERGENCY). NO CHANGE IN USE, EGRESS OR OCCUPANCY. SHED TO COMPLY WITH LL33/91
2003-07-07ECB Hazardous violation: FAILURE TO MAINTAIN EXTERIOR OF BUILDING WALL- DEFECT-NORTH ELEVATION AUSTIN STREET ORRIMENTAL PLASTER SPALLING & FALLING ONTO SID$800
2003-07-07DOB complaint, category ?
2002
2002-07-08Agreement — from NEW YORK COMMUNITYBANK to 771620 EQUITIES CORP
2002-07-08Mortgage $295,389 — from 771620 EQUITIES CORP to NEW YORK COMMUNITY BANK$295,389
2000
2000-05-03HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALL AND CEILING IN THE 1st BEDROOM FROM NORTH AT W
2000-05-03HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALL AND CEILING SOUTHEAST BEDROOM 2nd ROOM FROM SO
2000-02-07DOB violation LL6291:
1999
1999-09-08DOB violation E: 4P513
1999-08-11HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC WALL TILES OF BATHROOM 1 STY APT 1M. , SECTION '' ''
1999-08-11HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS OF BATHROOM 1 STY APT 1M
1999-08-11HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AROUND ENTRANCE DOOR TO APT 1 STY APT 1M. LOC
1999-08-11HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE SHOWERHEAD OF BATHROOM 1 STY APT 1M. , SECTION '' ''
1999-08-11HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WINDOW SILLS AND FRAMES THRUOUT 1 STY APT 1M. , SEC
1999-08-11HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC WALL TILES OF BATHROOM 1 STY APT 1M. , SECTION '' ''
1998
1998-02-09ECB Non-Hazardous violation: 57O,35P, 35-PROVIDE ACCESS SO THAT A COMPLETE INSPECTION CAN BE MAD EBY THIS DEPT.
1998-02-09ECB Non-Hazardous violation: 35P-PROVIDE ACCESS TO MOTOR ROOM SO A COMPLETE INSPECTION CAN BE MADE BY THIS DEPT.
1997
1997-06-05HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE GROUT AROUND BATHTUB BATHROOM 1 STY NORTHWEST APT 1M. , SEC
1997-06-05HPD class B: § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS HOPPER DOOR COMPARTMENT ROOM 1 STY APT 1. LOCATED AT APT 1
1997-06-05HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WALL LIGHT SWITCH KITCHEN 1 STY NORTHWEST APT 1M. , SECTION '' ''
1997-06-05HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERIOR DOOR JAMB ENTRANCE DOOR TO 1 STY APT 1M. , SECTION '' ''
1997-06-05HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MECHANICAL STOPPER WASHBASIN AND BATHTUB BATHROOM 1 STY APT 1M. , SECTION '' ''
1997-05-29Permit EQ — ISSUED
1997-05-08DOB complaint, category ?
1997-02-24Mortgage assigned — from WASHINGTON BANCORPORATION to QUEENS COUNTY SAVINGS BANK
1997-02-03Agreement — from QUEENS COUNTY SAVINGS BANK to 771620 EQUITIES CORP
1997-02-03REL — from WASHINGTON BANCORPORATION to 771620 EQUITIES CORP
1997-02-03Mortgage $370,000 — from 771620 EQUITIES CORP to QUEENS COUNTY SAVINGS BANK$370,000
1996
1996-10-07HPD class A: § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM
1995
1995-08-02HPD class A: § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKIN
1995-05-15HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING REAR YARD THRUOUT.
1995-05-15HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UPPER AND LOWER SASH WINDOW COUNTER BALANCE 1 STY APT 1M REAR ROOM. , SECTION ''
1995-05-15HPD class A: § 27-2005 ADM CODE REFIT INCINERATOR CLOSETS DOORS ALL STYS ALL SECTIONS R407.
1995-05-15HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE 3 STY APT 3J NORTHEAST ROOM NORTH WINDOW UPPER SASH. , SECTION ''
1995-05-15HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR KITCHEN 2 STY APT 2B. , SECTION '' ''
1995-05-15HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS THRUOUT 1 STY SOUTHWEST APT 1A.
1995-05-15HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING NORTHWEST ROOM 2 STY APT 2B. , SEC
1995-05-15HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING CLOSET NORTHWEST ROOM 2
1995-05-15HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS THRUOUT 1 STY APT 1M. , SECTION '
1995-05-15HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WASHBASIN STOPPER BATHROOM AT 1 STY APT 1M. , SECTION '' ''
1995-05-15HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALL BATHROOM AT 1 STY APT 1M.
1995-05-15HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ENTRANCE DOOR WOOD FRAME AT 1 STY APT 1M. , SECTION '' ''
1993
1993-07-12HPD class A: D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE PUTTY WINDOW THROUGHOUT 6 STY APT 6C. , SECTION '' ''
1993-07-12HPD class A: D26-20.05 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO CHAIN DOOR GUARD 6 ST
1993-07-12HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK SIDE OF DOOR JAMB ENTRANCE TO 6 STY APT 6H. , SECTION '' ''
1993-06-28DOB violation LL6291:
1992
1992-07-28Mortgage assigned — from VIENNA MTGE CORP to WASHINGTON BANCORPORATN
1992-07-28Mortgage assigned — from VIENNA MTGE CORP to WASHINGTON BANCORPORATN
1992-04-09ECB Non-Hazardous violation: 03#,52#,03O,03R,14R,18M,33L,50F,57O, 52.03 INSTALLED REFURBISH CAB WALLS AND NEW BRAKE WITHOUT A PERMIT. 03. PROVIDE 1800 LBS I$435
1992-04-09ECB Non-Hazardous violation: 03#,03M,03O,09M,14R,18M,26M,33M,47Y,57O, 03R, 03. INSTALL REFURNISH CAB WALLS WITHOUT A PERMIT.03.PROVIDE 1800 LBS IN CAB CAPACI$435
1991
1991-04-16ECB Non-Hazardous violation: 46L,73#,(46)SHORTER HOIST CABLES&PLACE IN PROPER SEQUENCE ON COUNTERWEIGHT END (73)CONDUCT A 5 YR TEST.
1991-04-16ECB Non-Hazardous violation: 5M,18M,52L,73#,8V,(5)GRILL GUARD (18)BASEMENT COVERS (52)REMOVE EXCESSIVE NOISE (73)CONDUCT A 5 YR TEST