A sustained record of distress well beyond its peers. More recorded distress than 98% of 6-24-unit residential buildings citywide. The citywide median for 6-24-unit residential buildings is 16.3 penalty
points per 10 units; this building carries 668.2. In ZIP 10029, 43% of residential buildings hold an A and
12% grade D or F.
How grades work
this building
A
B
C
Among 46,798 6-24-unit residential buildings citywide · left is less recorded distress, right is more
Open with the city right now
Open HPD violations
245 total — 71 class C (immediately hazardous), 139 class B, 35 class A. Oldest open since 2017-08-22.
Pending HPD litigation
1 case(s) pending in housing court
status snapshot refreshed weekly from HPD records
Patterns
35 heat or hot-water complaints in the last three years (winter 2024–25: 12 · winter 2025–26: 23). Repeated winter clusters suggest a chronic heating problem.
12
’24–25
23
’25–26
No bedbug-infested units reported in the last three years of filings.
$23,100 in enforcement penalties imposed (ECB/OATH) in the last three years.
What 311 hears from this address
82 service requests in the last three years. Most common: UNSANITARY CONDITION (27) · HEAT/HOT WATER (15) · WATER LEAK (10) · PAINT/PLASTER (9) · GENERAL (5) · APPLIANCE (4).
Filed construction activity
$1,727,280 in permitted construction work filed since
2016 (8 filings with a declared cost) — a rough measure of how actively
the owner maintains the building. Permit costs cover filed construction work only — they do not
capture routine maintenance or repairs done without a permit.
Rent-stabilization signals
Yes
Built before 1974 (1910)
Yes
Six or more residential units (12)
No
421-a / J-51 tax benefit on the current tax roll
2 of 3 signals present. This is the classic profile of a rent-stabilized building (pre-1974, 6+ units) — many units in such buildings remain stabilized. The definitive answer for any unit:
request its rent history from NYS Homes & Community Renewal (free, at hcr.ny.gov).
Registered with HPD — the names behind the building
Registered owner(s)
Neighborhood Renewal HFDC
Head officer
SALVATORE DAVOLA
Managing agent
CONCORD MANAGEMENT OF NY LLC
Last registered
2025-11-03
as filed by the owner in the building's HPD registration
What the city thinks it's worth
Tax year
City market value
Assessed value
2025
$0
$0
2026
$806,000
$362,700
2027
$922,995
$415,348
For property tax, the Department of Finance values this condo
as if it were a rental building. Its 2023 estimate: gross income $415,839 a year
($42.87 per sq ft), operating expenses $134,636
($13.88 per sq ft), net operating income $281,203. These are the
city's estimates from comparable rentals, not the building's actual budget, rents or maintenance
charges.
Flood exposure
Not in the FEMA 1%-annual-chance floodplain (2015 preliminary maps).
Hurricane evacuation zone 5 of 6 — zone 1 evacuates first.
Not in the city's stormwater (cloudburst) flood maps under any modeled scenario.
No street-flooding or sewer-backup complaints on record at this address.
Sources: FEMA flood maps (coastal), NYC DEP Stormwater Flood Maps
(cloudburst), NYC hurricane evacuation zones, and 311 records for this address.
Getting around
Subway
116 St — 6 · 300 ft straight-line (about a 1-minute walk) · station accessibility: none
Bus
Nearest boarding stop: E 116 St / Park Av — M102 M116 · 150 ft
Citi Bike
E 115 St & Lexington Ave · 350 ft · station location as of 2026-09-23; live availability
Distances are straight-line, not walking routes. Transit locations from the MTA and
Citi Bike, bike facilities from NYC DOT, school zones from the DOE's 2024–25 maps.
82 311 service requests from this address in the last three years — 15 of them about heat or hot water.
311 will ask for the address, the apartment if the problem is inside, and what's wrong.
Contact details are optional for most complaints; food-poisoning reports can be anonymous. Complaints
appear in the city's public 311 data, usually within a day or two, and then in the Live from 311 box
on this page.
Job filed: STRUCTURAL IN CONJUCTION WITH ARCHITECTURAL-CO #M01256340-I1
2026-10-13
HPD class I: § 27-2091(C) ADM CODE THE PROPERTY HAS BEEN ISSUED AN ORDER TO IDENTIFY AND ADDRESS UNDERLYING CONDITIONS AND VIOLATIONS RELATED TO THE ORDE
2026-10-10
City emergency repair (OMO): all mold remediation work to be done following safe work practice per new york state department of labor law article 32
2026-09-26
City emergency repair (OMO): location: apt 2a bathroom and adjacent private hallway repair leak and restore broken plaster. location of work: i) bath
2026-09-23
City emergency repair (OMO): at the bulkhead. make door self closing. nyc hpd emergency operations division essential service work'' at the bulkhe
2026-09-06
HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-09-06
HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WEST WALL IN THE PRIVATE H
2026-09-06
HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FT BUT LESS THAN 30SQ FT OBSERVED AT WE
2026-09-05
HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE PRIVATE HALLWAY ,
2026-09-05
HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT
2026-09-05
HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED A
2026-09-05
HPD class C: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING CEILING IN THE BATHROOM LOCATED AT APT 2A,
2026-09-05
HPD class C: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING CEILING IN THE PRIVATE HALLWAY LOCATED AT
2026-09-02
311: UNSANITARY CONDITION — MOLD
2026-09-02
311: WATER LEAK — HEAVY FLOW
2026-09-02
311: PAINT/PLASTER — CEILING
2026-09-02
Tenant complaint: UNSANITARY CONDITION — MOLD
2026-09-02
Tenant complaint: WATER LEAK — HEAVY FLOW
2026-09-02
Tenant complaint: PAINT/PLASTER — CEILING
2026-08-31
HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ.FT. BUT LESS THAN 30 SQ.FT. OBSERVED
2026-08-31
HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE 2nd ROOM
2026-08-31
HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5A, 5th STORY, 1st AP
2026-08-31
HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE 1st ROOM
2026-08-31
HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT. OBSERVED AT NORTH WALL AROUND THE W
2026-08-31
HPD class C: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 5A, 5th STORY, 1st AP
2026-08-25
HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-08-25
HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 5th STORY
2026-08-25
HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED A
2026-08-25
HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STO
2026-08-25
HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM NORTH L
2026-08-25
HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE CLOSET IN THE 1st ROOM
2026-08-25
HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 5th STORY
2026-08-25
HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCES AT WINDOW AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATE
2026-08-25
HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 5th STOR
2026-08-25
HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL/RETURN BUZZER SYSTEM FROM BUILDING FRONT TO EAST WALL PANEL IN THE FO
2026-08-25
HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT
2026-08-07
DOB complaint, category ?
2026-08-07
DOB complaint, category ?
2026-08-07
ECB CLASS - 1 violation: FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. OBSERVED IN APT#3A MOLD GROWING THROUGHOUT THE ENTIRE APARTMENT AND FLIES A
2026-08-07
ECB CLASS - 1 violation: OBSERVED IN APT 3A A LEAK IN BEDROOM AND BATHROOM TOILET HAS A SEVERE CLOG AND OBSTRUCTED SPRINKLER HEAD IN THE LIVING ROOM WHICH
2026-08-07
ECB CLASS - 1 violation: OBSERVED IN APT# 3A IN THE REAR BEDROOM THE A/C RECEPTACLE IS NOT WORKING SHOWING SIGNS OF SPARKING ON THE FACE OF THE OUTLET. ALS
2026-08-05
DOB complaint, category ?
2026-07-10
Rodent inspection: Passed
2026-07-06
HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-07-06
HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FR
2026-07-06
HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL VENTILATION FAN AT CEILING IN THE BATHROOM LOCATED AT APT 5B, 5
2026-07-06
HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT BULKHEAD AT ROOF
2026-07-06
HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND SOUTH WALL AT PUBLIC HALL STAIRS, 1s
2026-07-06
HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE DECKING MEMBRANE AT CENTER EAST AND CENTER WEST AT ROOF
2026-07-06
HPD class B: § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE ENTIRE ROOF AREA
2026-07-06
HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 5th STORY
2026-07-06
HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 5th STOR
2026-07-06
HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND SOUTH WALL AT PUBLIC
2026-07-06
HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 5th STORY
2026-07-06
HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT BULKHEAD AT ROOF
2026-07-06
HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND SOUTH WALL AT PUBLIC HALL STAIRS, 1st
2026-07-06
HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT SKYLIGHT AT BULKHEAD AT ROOF
2026-06-18
HPD class C: § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET ... IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SO
2026-06-18
HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2026-06-18
HPD class B: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE UNHINGED DOOR IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
2026-06-18
HPD class C: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQUARE FEET AT NORTH WALL, EAST WALL, W
2026-06-18
HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2026-06-18
HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL, EAST WALL, WEST WALL AND C
2026-06-18
HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL AND CEILING IN THE 5th ROOM
2026-06-18
HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOC
2026-06-18
HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 3
2026-06-18
HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT
2026-06-18
HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE PRIVATE HALLWAY LOCAT
2026-06-18
HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQUARE FEET AT CEILING AND SOUTH WALL IN T
2026-06-18
HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE NORTH CLOSET
2026-06-18
HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 3A, 3rd STOR
2026-06-18
HPD class C: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQUARE AT NORTH WALL AND CEILING IN THE
2026-06-18
HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING AND SOUTH WALL IN T
2026-06-18
HPD class A: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT CEILING IN THE 5th ROOM FROM NORTH LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2026-06-18
HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE KITCHEN LOCA
2026-06-18
HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE NORTH CLOSET. IN THE 1s
2026-06-18
HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-06-18
HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE EAST WALL ELECTRICAL OUTLET IN THE 1st ROOM FROM NORTH LOCATED AT APT 3A,
2026-06-18
HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3A
2026-06-18
HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT NORTH WALL IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY,
showing the 80 most recent
The full timeline
2026
2026-10-13Job filed: STRUCTURAL IN CONJUCTION WITH ARCHITECTURAL-CO #M01256340-I1$5,000
2026-10-13HPD class I: § 27-2091(C) ADM CODE THE PROPERTY HAS BEEN ISSUED AN ORDER TO IDENTIFY AND ADDRESS UNDERLYING CONDITIONS AND VIOLATIONS RELATED TO THE ORDE
2026-10-10City emergency repair (OMO): all mold remediation work to be done following safe work practice per new york state department of labor law article 32
2026-09-26City emergency repair (OMO): location: apt 2a bathroom and adjacent private hallway repair leak and restore broken plaster. location of work: i) bath$1,990
2026-09-23City emergency repair (OMO): at the bulkhead. make door self closing. nyc hpd emergency operations division essential service work'' at the bulkhe$295
2026-09-06HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-09-06HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WEST WALL IN THE PRIVATE H
2026-09-06HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FT BUT LESS THAN 30SQ FT OBSERVED AT WE
2026-09-05HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE PRIVATE HALLWAY ,
2026-09-05HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT
2026-09-05HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED A
2026-09-05HPD class C: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING CEILING IN THE BATHROOM LOCATED AT APT 2A,
2026-09-05HPD class C: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING CEILING IN THE PRIVATE HALLWAY LOCATED AT
2026-08-31HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ.FT. BUT LESS THAN 30 SQ.FT. OBSERVED
2026-08-31HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE 2nd ROOM
2026-08-31HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5A, 5th STORY, 1st AP
2026-08-31HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE 1st ROOM
2026-08-31HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT. OBSERVED AT NORTH WALL AROUND THE W
2026-08-31HPD class C: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 5A, 5th STORY, 1st AP
2026-08-25HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-08-25HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 5th STORY
2026-08-25HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED A
2026-08-25HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STO
2026-08-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM NORTH L
2026-08-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE CLOSET IN THE 1st ROOM
2026-08-25HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 5th STORY
2026-08-25HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCES AT WINDOW AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATE
2026-08-25HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 5th STOR
2026-08-25HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL/RETURN BUZZER SYSTEM FROM BUILDING FRONT TO EAST WALL PANEL IN THE FO
2026-08-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT
2026-08-07DOB complaint, category ?
2026-08-07DOB complaint, category ?
2026-08-07ECB CLASS - 1 violation: FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER. OBSERVED IN APT#3A MOLD GROWING THROUGHOUT THE ENTIRE APARTMENT AND FLIES A$6,250
2026-08-07ECB CLASS - 1 violation: OBSERVED IN APT 3A A LEAK IN BEDROOM AND BATHROOM TOILET HAS A SEVERE CLOG AND OBSTRUCTED SPRINKLER HEAD IN THE LIVING ROOM WHICH $6,250
2026-08-07ECB CLASS - 1 violation: OBSERVED IN APT# 3A IN THE REAR BEDROOM THE A/C RECEPTACLE IS NOT WORKING SHOWING SIGNS OF SPARKING ON THE FACE OF THE OUTLET. ALS$4,000
2026-08-05DOB complaint, category ?
2026-07-10Rodent inspection: Passed
2026-07-06HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-07-06HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FR
2026-07-06HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL VENTILATION FAN AT CEILING IN THE BATHROOM LOCATED AT APT 5B, 5
2026-07-06HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT BULKHEAD AT ROOF
2026-07-06HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND SOUTH WALL AT PUBLIC HALL STAIRS, 1s
2026-07-06HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE DECKING MEMBRANE AT CENTER EAST AND CENTER WEST AT ROOF
2026-07-06HPD class B: § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE ENTIRE ROOF AREA
2026-07-06HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 5th STORY
2026-07-06HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 5th STOR
2026-07-06HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND SOUTH WALL AT PUBLIC
2026-07-06HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 5th STORY
2026-07-06HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT BULKHEAD AT ROOF
2026-07-06HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND SOUTH WALL AT PUBLIC HALL STAIRS, 1st
2026-07-06HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT SKYLIGHT AT BULKHEAD AT ROOF
2026-06-18HPD class C: § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS FROM WATER CLOSET ... IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SO
2026-06-18HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2026-06-18HPD class B: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE UNHINGED DOOR IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
2026-06-18HPD class C: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQUARE FEET AT NORTH WALL, EAST WALL, W
2026-06-18HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2026-06-18HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL, EAST WALL, WEST WALL AND C
2026-06-18HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL AND CEILING IN THE 5th ROOM
2026-06-18HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOC
2026-06-18HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 3
2026-06-18HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT
2026-06-18HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE PRIVATE HALLWAY LOCAT
2026-06-18HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQUARE FEET AT CEILING AND SOUTH WALL IN T
2026-06-18HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE NORTH CLOSET
2026-06-18HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 3A, 3rd STOR
2026-06-18HPD class C: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQUARE AT NORTH WALL AND CEILING IN THE
2026-06-18HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING AND SOUTH WALL IN T
2026-06-18HPD class A: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT CEILING IN THE 5th ROOM FROM NORTH LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2026-06-18HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE KITCHEN LOCA
2026-06-18HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE NORTH CLOSET. IN THE 1s
2026-06-18HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-06-18HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE EAST WALL ELECTRICAL OUTLET IN THE 1st ROOM FROM NORTH LOCATED AT APT 3A,
2026-06-18HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3A
2026-06-18HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT NORTH WALL IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY,
2026-06-18HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STO
2026-06-18HPD class B: § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVI
2026-06-18HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE 1st ROOM FROM
2026-06-18HPD class B: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST A
2026-06-18HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE NORTH CLOSET IN THE 1st ROOM FROM N
2026-06-18HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL, AND CEILING IN THE 1st ROOM FROM NORTH
2026-06-18DOB complaint, category ?
2026-05-14HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-05-14HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2026-05-14HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INOPERATIVE INTERCOM SYSTEM FROM BUILDING FRONT ENTRANCE TO WEST WALL PANE
2026-05-14HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 3A, 3rd
2026-05-14HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE 5th ROOM FROM NOR
2026-05-14HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE BATHROOM LOCA
2026-05-14HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3A, 3rd
2026-05-14HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st
2026-05-14HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 5th ROOM FROM NORTH LOCATED AT APT 3A, 3rd
2026-05-14HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE 2nd ROOM FROM
2026-05-14HPD class B: § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVI
2026-05-14HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY, 1st
2026-05-14HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE 1st ROOM FROM
2026-05-14DOB complaint, category ?
2026-05-14DOB complaint, category ?
2026-05-14DOB complaint, category ?
2026-05-14ECB CLASS - 1 violation: OBSERVED IN APT 3A A LEAK IN BEDROOM AND BATHROOM TOILET HAS SERVE CLOG AND OBSTRUCTED SPRINKLER HEAD IN LIVINGROOM WHICH IS CONTR$2,500
2026-05-14ECB CLASS - 1 violation: UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN APT 3A $1,600
2026-05-14ECB CLASS - 1 violation: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED IN APT 3A THE PRESENT OF BLACK MOLD GROWING THRU OUT THE ENTIRE AP$2,500
2026-05-13DOB complaint, category ?
2026-05-08311: APPLIANCE — ELECTRIC/GAS RANGE
2026-05-08311: Noise — Noise: Construction Equipment (NC1)
2026-05-08Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2026-04-27City emergency repair (HWO): nyc hpd emergency operations division essential service work apt # 2a install/repair w/gs throughout apt. remove al
2026-04-27Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2026-04-27Tenant complaint: PLUMBING — TOILET
2026-04-27Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-04-13Mortgage satisfied — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to NEW YORK CITY HOUSING DEVELOPMENT CORPOR
2026-04-13Agreement $79,338,695 — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to THE CITY OF NEW YORK$79,338,695
2026-04-13Mortgage satisfied — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to NEW YORK CITY HOUSING DEVELOPMENT CORPOR
2026-04-13Agreement $79,338,695 — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to THE CITY OF NEW YORK$79,338,695
2026-04-13Agreement $745,152 — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to THE CITY OF NEW YORK$745,152
2026-04-13Mortgage $4,496,942 — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to THE CITY OF NEW YORK$4,496,942
2026-04-13Mortgage $5,286,000 — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to NEW YORK CITY HOUSING DEVELOPMENT CORPOR$5,286,000
2026-04-13Mortgage assigned — from NEW YORK CITY HOUSING DEVELOPMENT CORPOR to THE CITY OF NEW YORK
2026-04-13AL&R $5,286,000 — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to NEW YORK CITY HOUSING DEVELOPMENT CORPOR$5,286,000
2026-04-13Agreement $745,152 — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to THE CITY OF NEW YORK$745,152
2026-04-13Mortgage $4,496,942 — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to THE CITY OF NEW YORK$4,496,942
2026-04-13Mortgage $5,286,000 — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to NEW YORK CITY HOUSING DEVELOPMENT CORPOR$5,286,000
2026-04-13Mortgage assigned — from NEW YORK CITY HOUSING DEVELOPMENT CORPOR to THE CITY OF NEW YORK
2026-04-13AL&R $5,286,000 — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to NEW YORK CITY HOUSING DEVELOPMENT CORPOR$5,286,000
2026-04-13AALR — from NEW YORK CITY HOUSING DEVELOPMENT CORPOR to THE CITY OF NEW YORK
2026-04-13AALR — from NEW YORK CITY HOUSING DEVELOPMENT CORPOR to THE CITY OF NEW YORK
2026-04-07HPD litigation: Tenant Action
2026-03-24HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2A,
2026-03-24HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STO
2026-03-24HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT
2026-03-24HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT
2026-03-24HPD class B: § 27-2005 HMC: REFIT DOOR IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
2026-03-24HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE PR
2026-03-24HPD class C: § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CI
2026-03-23311: HEAT/HOT WATER — APARTMENT ONLY
2026-03-23311: PAINT/PLASTER — WALL
2026-03-23311: WATER LEAK — HEAVY FLOW
2026-03-23Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-03-23Tenant complaint: WATER LEAK — HEAVY FLOW
2026-03-23Tenant complaint: PAINT/PLASTER — WALL
2026-03-12HPD litigation: Tenant Action
2026-02-19CERT — from BENCHMARK TITLE AGENCY LLC
2026-02-19CERT — from BENCHMARK TITLE AGENCY LLC
2026-02-19ZONE — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT
2026-02-19ZONE — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT
2026-02-13HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT
2026-02-13HPD class C: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 30 SQFT AT CEILING AND ALL WALLS IN THE BA
2026-02-13HPD class C: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT A
2026-02-13HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM NORT
2026-02-13HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FR
2026-02-13HPD class C: § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MIS
2026-02-13HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2026-02-13HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQFT AT CEILING AND SOUTH WALL IN THE 2
2026-02-13HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQFT AT CEILING IN THE 5th ROOM FROM NO
2026-02-13HPD class C: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 30 SQFT AT CEILING IN THE 1st ROOM FROM NO
2026-02-13HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM
2026-02-13HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 10 SQFT AT CEILING IN THE KITCHEN LOCATED AT
2026-02-13HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 10 SQFT AT CEILING IN THE KITCHEN LOCATED AT
2026-02-13HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL AND CEILING IN THE 1st ROOM
2026-02-11311: HEAT/HOT WATER — APARTMENT ONLY
2026-02-11311: HEAT/HOT WATER — APARTMENT ONLY
2026-02-11Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-02-11Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-02-05HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE 2nd ROOM FROM NORT
2026-02-05HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT
2026-02-05HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST
2026-02-05HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT CELING AND NORTH AND EAST WALL
2026-02-05HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE 3rd ROOM FROM NORT
2026-02-05HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT CEILING AND ALL WALLS. IN THE
2026-02-05HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE 3rd ROOM FROM NORT
2026-02-05HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING IN THE 2nd ROOM FROM NORT
2026-02-05HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT CELLAR AT BOILER ROOM
2026-02-03311: WATER LEAK — HEAVY FLOW
2026-02-03311: HEAT/HOT WATER — APARTMENT ONLY
2026-02-03311: Snow or Ice — Sidewalk
2026-02-03Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-02-03Tenant complaint: WATER LEAK — HEAVY FLOW
2026-02-01311: HEAT/HOT WATER — APARTMENT ONLY
2026-02-01Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-01-27HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FR
2026-01-27HPD class B: § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVI
2026-01-27HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2026-01-25311: HEAT/HOT WATER — APARTMENT ONLY
2026-01-25311: UNSANITARY CONDITION — PESTS
2026-01-25Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2026-01-13Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2025
2025-12-12Bedbug filing: 0 infested units
2025-10-28311: DOOR/WINDOW — DOOR
2025-10-28311: HEAT/HOT WATER — APARTMENT ONLY
2025-10-28Tenant complaint: DOOR/WINDOW — DOOR
2025-10-28Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2025-10-27Job filed: FACADE RESTORATION FOR 108 EAST 116 STREET$500,000
2025-10-13Job filed: PLUMBING IN CONJUCTION WITH ARCHITECTURAL-CO # M01256340-I1$5,000
2025-10-13Job filed: SPRINKLER IN CONJUCTION WITH ARCHITECTURAL-CO #M01256340-I1$5,000
2025-10-13Job filed: MECHINCAL IN CONJUCTION WITH ARCHITECTURAL-CO # M01256340-I1$5,000
2025-10-09Job filed: STRUCTURAL IN CONJUCTION WITH ARCHITECTURAL-CO #M01256340-I1$5,000
2025-10-02City emergency repair (OMO): restore electricty in proper manner at apt 3a, 3rd story, 1st apartment from east at south nyc hpd emergency operations $2,990
2025-10-02City emergency repair (OMO): water closet located at apt 3a bathroom , 3rd story, 1st apartment from east at south nyc hpd emergency operations divis$877
2025-09-25Job filed: This application proposes an interior renovation of an existing 5-story residential building. The scope of work includes the reconfiguration of existi$1,188,480
2025-08-13HPD class C: § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT THE CEILING
2025-08-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VENTILATION COVER PLATE AT CEILING IN THE KITCHEN LOCATED A
2025-08-13HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ALL WALLS IN THE KITCHE
2025-08-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN BASEBOARD MOLDING AT THE EAST WALL IN THE KITCHEN LO
2025-08-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN ENTRY DOOR IN THE BATHROOM LOCATED AT APT 3A, 3rd ST
2025-08-13HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT THE CEILING IN THE KITCHEN LOCATED AT APT 3A, 3rd STORY,
2025-08-13HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 3A,
2025-08-13HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 3A,
2025-08-13HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS IN THE 1st ROOM FROM NORTH LO
2025-08-13HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BUILDING BELL INTERCOM SYSTEM FROM BUILDING FRONT ENTRANCE TO PANEL AT NOR
2025-08-13HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND KEY SET TO MAILBOX FOR APT 3A ON EAST WALL AT VESTIBULE AREA , 1s
2025-08-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VENTILATION COVER PLATE AT CEILING IN THE 1st ROOM FROM NOR
2025-08-13HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 3A, 3rd
2025-08-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL VENTILATION PLATE COVERS AT THE CEILING IN THE 5th RO
2025-08-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL VENTILATION COVER PLATE AT CEILING IN THE 3rd BATHROO
2025-08-13HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ALL WALLS IN THE 5th RO
2025-08-13HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ALL WALLS IN THE PRIVAT
2025-08-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL VENTILATION COVER PLATE AT CEILING IN THE 2nd ROOM FR
2025-08-13HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HARDWOOD FLOORS IN THE 5th ROOM FROM NORTH LOCATED AT APT 3
2025-08-13HPD class B: § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVI
2025-08-13HPD class B: § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN AC
2025-08-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL VENTILATION COVER AT THE CEILING IN THE BATHROOM LOCA
2025-08-13HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ALL WALLS IN THE BATHRO
2025-08-13HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND ALL WALLS IN THE 2nd RO
2025-08-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL GLAZE AT BATHTUB IN THE BATHROOM LOCATED A
2025-08-13HPD class B: § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SCONCE LIGHT AT THE NORTH WALL IN THE BATHROOM LOCATED AT APT 3A, 3rd STOR
2025-08-13HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING, EAST WALL, SOUTH WALL, WEST WALL, AND N
2025-08-13HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING, NORTH WALL, EAST WALL, AND WEST WALL
2025-08-13HPD class C: § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT THE SOUTH WA
2025-08-13HPD class C: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE LIGHT FIXTURE AT THE CEILING IN THE 5th ROOM FROM NORTH LOCATED AT APT 3A, 3rd STORY, 1st APART
2025-08-13HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING, SOUTH WALL, WEST WALL, AND EAST WALL
2025-08-13HPD class C: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING, NORTH WALL, EAST WALL, AND WEST WALL GR
2025-08-13HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING, EAST WALL, AND WEST WALL IN THE PRIVA
2025-08-13HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING, EAST WALL, AND NORTH WALL LESS THAN 25
2025-08-13HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING, SOUTH WALL, AND EAST WALL LESS THAN 30
2025-08-13HPD class C: § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT THE CEILING
2025-08-13HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING, EAST WALL, AND SOUTH WALL IN THE KITC
2025-08-13HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING, EAST WALL, NORTH WALL, AND WEST WALL
2025-08-13HPD class C: § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT THE CEILING
2025-08-13HPD class C: § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WATER CLOSET IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOU
2025-08-13HPD class C: 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND A
2025-08-13HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FR
2025-08-13HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING LESS 20 SQUARE FEET IN THE KITCHEN LOCAT
2025-08-13HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE CEILING, EAST WALL, AND WEST WALL LESS THAN 20 S
2025-08-13HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING, EAST WALL, AND NORTH WALL IN THE 1st
2025-08-13HPD class C: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING IN THE 1st ROOM FROM NORTH
2025-04-10HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM
2025-04-10HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT EAST WALL IN THE BATHROOM LOCATED
2025-04-10HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING OVER THE WINDOW AT NORTH
2025-04-10HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAS
2025-04-10HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND OVER THE WINDOW AT NORTH WA
2025-04-10HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING OVER THE WINDOW AT NORTH WALL IN THE 1st R
2025-04-10HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING OVER THE WINDOW AT NORTH
2025-04-10HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT EAST WALL IN THE BATHROOM LOCATED
2025-04-10HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE BATHROOM L
2025-04-10HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE 5th ROOM FROM NORTH LO
2025-04-10HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE FOYER LOCA
2025-04-10HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1s
2025-03-17Tenant complaint: WATER LEAK — HEAVY FLOW
2025-01-21311: HEAT/HOT WATER — APARTMENT ONLY
2025-01-21Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2025-01-15Rodent inspection: Passed
2024
2024-12-22311: HEAT/HOT WATER — APARTMENT ONLY
2024-12-22Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2024-12-22HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FR
2024-12-22HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3
2024-12-22HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE PRIVATE HALLWAY LOCAT
2024-12-20311: HEAT/HOT WATER — APARTMENT ONLY
2024-12-20Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2024-12-19311: HEAT/HOT WATER — ENTIRE BUILDING
2024-12-19311: Water System — Dirty Water (WE)
2024-12-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2024-12-12311: HEAT/HOT WATER — ENTIRE BUILDING
2024-12-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2024-12-12HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3
2024-12-12HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM N
2024-12-12HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY,
2024-12-12HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH IN THE PRIVATE HALLWAY LOCATED AT
2024-12-12HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FR
2024-12-10Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2024-07-16Rodent inspection: Passed
2024-06-12HPD class A: § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL COMPONENTS AT ALL STOR
2024-04-19Agreement — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to THE CITY OF NEW YORK, ACTING BY AND THRO
2024-04-19Agreement — from NEIGHBORHOOD RENEWAL HOUSING DEVELOPMENT to THE CITY OF NEW YORK, ACTING BY AND THRO
2023-11-25HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTME
2023-11-25HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FR
2023-10-24311: UNSANITARY CONDITION — PESTS
2023-10-24311: UNSANITARY CONDITION — PESTS
2023-10-24311: APPLIANCE — REFRIGERATOR
2023-10-24311: APPLIANCE — REFRIGERATOR
2023-10-24311: GENERAL — BELL/BUZZER/INTERCOM
2023-10-24Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2023-07-19Rodent inspection: Failed for Rat Activity and Other Reason
2023-07-18Rodent inspection: Passed
2023-07-12HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR LEADING TO ROOM WITH FIRE ESCAPE IN THE 1st ROOM
2023-07-12HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS AT PUBLIC HALL, 2nd STORY
2023-07-07HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FR
2023-07-07HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTME
2023-07-07HPD class B: § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR AT PUBLIC HALL,
2023-06-25Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-06-25HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 4A
2023-06-25HPD class A: § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM
2023-06-25HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RAT INFESTATION AT PUBLIC HALL STAIRS
2023-06-25HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM EAST
2023-06-25HPD class C: § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO H
2023-06-25HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM
2023-06-23311: HEAT/HOT WATER — ENTIRE BUILDING
2023-06-23Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-06-22311: HEAT/HOT WATER — ENTIRE BUILDING
2023-06-22311: HEAT/HOT WATER — APARTMENT ONLY
2023-06-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2023-06-22Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-12-19Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-12-08Bedbug filing: 0 infested units
2022-11-29HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE KITCHEN , THE 3rd
2022-11-24311: ELECTRIC — NO LIGHTING
2022-11-24311: APPLIANCE — ELECTRIC/GAS RANGE
2022-11-24Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2022-11-24Tenant complaint: ELECTRIC — NO LIGHTING
2022-09-01311: Rodent — Rat Sighting
2022-08-24311: Rodent — Rat Sighting
2022-08-15Rodent inspection: Failed for Rat Activity
2022-04-27311: Rodent — Rat Sighting
2022-04-13HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STO
2022-04-13HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT
2022-02-21Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-02-19HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM
2022-02-18Job filed: INSTALL NEW EXHAUST VENT AS PER PLANS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.$13,800
2022-02-16HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FR
2022-02-16HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM SOUT
2022-02-16HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM
2022-02-16HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM METAL FLAP DOOR TO CELLAR LOCKED AT FRONT OF BLDG AT BOILER ROOM
2022-02-16HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY,
2022-02-16HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM S
2022-02-14311: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-02-12Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2022-02-12Tenant complaint: ELECTRIC — NO LIGHTING
2022-02-11311: Broken Parking Meter — Out of Order
2022-02-11HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL BUZZER INTRECOM SYSTEM FROM THE BUILDING ENTRANCE DOOR TO THE APARTMENT WALL
2022-02-11HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM CELLAR DOOR LOCKED AT BOILER ROOM
2022-02-11HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM EAST
2022-02-10311: HEAT/HOT WATER — APARTMENT ONLY
2022-02-10Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-02-04ECB CLASS - 1 violation: I OBSERVED THAT LMP NUMBER 002184 FIELD FOR LAA PERMIT. LAA PERMIT NUMBER M00450932 TO INSTALLED HOT WATER HEATER BOILER WHICH IS
2022-02-03DOB complaint, category ?
2022-02-03DOB violation P: COMMISSIONERS REQUEST FOR IMMEDIATE CORRECTIVE ACTION I OBSERVED IN CELLAR HOT WATER HEATER VENT IS NOT INSTALLED OBSERVED CONDI
2022-01-18311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-18Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-10311: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-10Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2022-01-07311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-07Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2022-01-04311: HEAT/HOT WATER — APARTMENT ONLY
2022-01-04Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021
2021-12-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-12-29311: GENERAL — CABINET
2021-12-29311: WATER LEAK — HEAVY FLOW
2021-12-29311: PAINT/PLASTER — CEILING
2021-12-29311: APPLIANCE — REFRIGERATOR
2021-12-29311: UNSANITARY CONDITION — MOLD
2021-12-29311: UNSANITARY CONDITION — PESTS
2021-12-29311: UNSANITARY CONDITION — PESTS
2021-12-29311: PAINT/PLASTER — WALL
2021-12-14Bedbug filing: 0 infested units
2021-12-01311: APPLIANCE — ELECTRIC/GAS RANGE
2021-12-01311: HEAT/HOT WATER — APARTMENT ONLY
2021-12-01Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2021-12-01Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-11-03HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND SOUTH WALLS AT PUBLIC HALL, 2nd STORY
2021-11-03HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
2021-11-03HPD class B: § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AN
2021-11-03HPD class B: § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD MATTRESS AND FURNITURE AT PUBLIC HALL, 1st STORY
2021-11-03HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND SOUTH WALL AT PUBLIC HALL, 2nd STORY
2021-11-03HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WITH FIRE RETARDANT MATERIAL AT SOUTH WALL AND CEILING AT P
2021-11-03HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY
2021-11-03HPD class C: § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT
2021-11-02311: APPLIANCE — ELECTRIC/GAS RANGE
2021-11-02311: APPLIANCE — REFRIGERATOR
2021-11-02311: HEAT/HOT WATER — APARTMENT ONLY
2021-11-02Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2021-11-02Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2021-10-18HPD class C: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (APPROX. 15 SQ. FT.) IN THE BATHROOM LOCATED
2021-10-18HPD class A: § 27-2005 ADM CODE REFIT ENTERANCE DOOR IN THE 4th ROOM FROM NORTH LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
2021-10-18HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILINGS AND WALLS THROUGHOUT IN THE ENTIRE APA
2021-10-18HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FR
2021-10-18HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT CEILING IN THE KITCHEN LOCATED AT APT 3B, 3rd ST
2021-10-18HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 3B, 3rd STOR
2021-10-18HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STO
2021-10-18HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE BATHROOM LOCA
2021-10-18HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM PANEL AT NORTH WALL IN THE FOYER LOCATED AT APT 3B, 3rd STORY, 2n
2021-10-18HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ENTERANCE DOOR IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM
2021-10-18HPD class C: § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FRO
2021-10-18HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE KITCHEN LO
2021-10-18HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (APPROX. 15 SQ. FT.) IN THE BATHROOM LOCATED
2021-10-13311: GENERAL — BELL/BUZZER/INTERCOM
2021-10-13311: DOOR/WINDOW — DOOR
2021-10-13311: GENERAL — BELL/BUZZER/INTERCOM
2021-10-13311: APPLIANCE — ELECTRIC/GAS RANGE
2021-10-13311: GENERAL — COOKING GAS
2021-10-13311: WATER LEAK — DAMP SPOT
2021-10-13Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2021-10-13Tenant complaint: DOOR/WINDOW — DOOR
2021-10-13Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2021-10-13Tenant complaint: GENERAL — COOKING GAS
2021-10-13Tenant complaint: WATER LEAK — DAMP SPOT
2021-10-13Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2021-08-25HPD class A: § 27-2005 ADM CODE REFIT LIGHT FIXTURE AT WEST WALL IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
2021-08-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, NORTH AND EAST WALL IN THE 1st
2021-08-25HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND SINK COUNTERTOP IN THE KITCHEN LOCATED AT A
2021-08-25HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL, RETURN BUZZER AND INTERCOM SYSTEM FROM FRONT BUILDING ENTRANCE DOOR TO APAR
2021-08-19311: UNSANITARY CONDITION — MOLD
2021-08-19311: PAINT/PLASTER — CEILING
2021-08-19311: PLUMBING — WATER SUPPLY
2021-08-19311: SAFETY — SMOKE DETECTOR
2021-08-19311: GENERAL — BELL/BUZZER/INTERCOM
2021-08-19311: GENERAL — CABINET
2021-08-19311: ELECTRIC — LIGHTING
2021-08-19311: PLUMBING — BATHTUB/SHOWER
2021-08-19Tenant complaint: PLUMBING — WATER SUPPLY
2021-05-01311: NonCompliance with Phased Reopening — Restaurant/Bar Not in Compliance
2021-04-01Bedbug filing: 0 infested units
2021-04-01HPD class A: (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPD
2021-02-25HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ...AT THE CEILING IN THE 1st ROOM FROM NORTH LOCATED
2021-02-25HPD class C: § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER LOCK AT THE ROOM DOOR LEADING TO THE FIRE ESCAPE IN THE 5th ROOM FROM
2021-02-25HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE THE BELL BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE TO THE NORTH WALL... I
2021-02-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE 1st ROOM
2021-02-25HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE THE BELL BUZZER SYSTEM FROM THE BUILDING ENTRANCE TO THE NORTH WALL .... IN THE F
2021-02-25HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ....LOCKSET AT ENTRANCE DOOR IN THE 5th ROOM FROM NORTH LOCATED AT APT 3A, 3rd ST
2021-02-25HPD class B: § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN THE BATHROOM LOCATED A
2021-02-19311: PLUMBING — BASIN/SINK
2021-02-19311: PLUMBING — TOILET
2021-02-19Tenant complaint: PLUMBING — TOILET
2021-02-19Tenant complaint: PLUMBING — BASIN/SINK
2021-02-16311: HEAT/HOT WATER — ENTIRE BUILDING
2021-02-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-02-01311: HEAT/HOT WATER — ENTIRE BUILDING
2021-02-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2021-01-05311: GENERAL — BELL/BUZZER/INTERCOM
2021-01-05311: DOOR/WINDOW — DOOR
2021-01-05Tenant complaint: DOOR/WINDOW — DOOR
2021-01-05Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2021-01-01311: GENERAL — BELL/BUZZER/INTERCOM
2021-01-01311: DOOR/WINDOW — DOOR
2021-01-01Tenant complaint: GENERAL — BELL/BUZZER/INTERCOM
2021-01-01Tenant complaint: DOOR/WINDOW — DOOR
2020
2020-12-30311: HEAT/HOT WATER — ENTIRE BUILDING
2020-12-10Rodent inspection: Passed
2020-12-08HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 3C, 3rd
2020-12-08HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 15 SQUARE FEET AT THE CEILING IN THE BATH
2020-12-08HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND THE WEST WALL IN THE BATHR
2020-12-08HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER WOOD CABINET DOOR ON THE EAST WALL IN THE KITCHEN LOCATED AT APT 3C, 3rd ST
2020-12-01311: Homeless Person Assistance
2020-11-29HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 4A,
2020-11-29HPD class B: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APROX 5 SQ FT AT CEILING IN THE 1st ROOM FROM NORTH LOC
2020-11-29HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND NORTH WALL IN THE 1st ROOM FRO
2020-11-29HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APROX 5 SQ FT AT CEILING IN THE 1st ROOM FROM NORTH LOC
2020-11-29HPD class B: § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONING UNIT
2020-08-25HPD class C: § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES NO GAS AT RANGE FOR COOKING IN THE KITCHEN LOCATED AT APT 4A, 4th STORY
2020-08-13311: GENERAL — COOKING GAS
2020-08-13Tenant complaint: GENERAL — COOKING GAS
2020-07-31311: APPLIANCE — ELECTRIC/GAS RANGE
2020-07-31Tenant complaint: APPLIANCE — ELECTRIC/GAS RANGE
2020-01-15HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTM
2020-01-15HPD class B: § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APART
2020-01-15HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WINDOW CASING IN THE 1st ROOM FROM NOR
2020-01-15HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL DOOR LOCK AT THE BUILDING ENTRANCE , 1st STORY
2020-01-15HPD class A: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WINDOW CASING IN THE 1st ROOM FROM NORTH LOCATED A
2020-01-08HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FR
2019
2019-10-31HPD class B: § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR COND
2019-10-31HPD class B: § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF GARBBAGE BINS STORED AT SOUTH SECTION AT PUBLIC HALL, 1st STORY
2019-10-31DOB complaint, category ?
2019-10-24HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FR
2019-10-24HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FR
2019-10-24HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM
2019-10-24HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM
2019-10-24HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FR
2019-10-01FDNY inspection (RISK)
2019-07-16Rodent inspection: Passed
2019-07-16HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FR
2019-07-16HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FR
2019-07-16HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FR
2019-07-16HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FR
2019-07-16HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FR
2019-07-16HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM
2019-07-16HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVER AT CEILING FOR HEATING SYSTEM IN THE 1st ROOM FROM NORTH LOCATED AT APT 4B, 4th STORY,
2019-07-16HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM AT SOUTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2C, 2nd STORY, 1
2019-07-16HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NOR
2019-07-16HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE TOWEL RACK AT EAST WALL IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTM
2019-07-16HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR FRAME AT ENTRANCE IN THE 5th ROOM FROM NORTH LOCA
2019-07-16HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM NORTH L
2019-07-16HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD DOOR AT ENTRANCE IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 2nd APARTMEN
2019-07-16HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH LOCA
2019-07-16HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 4C,
2019-07-16HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK THROUGHOUT CEILING IN THE BATHROOM LOCATED AT APT 4C,
2019-07-16HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1s
2019-07-16HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT DOOR AT ENTRANCE IN THE 5th ROOM FROM NORTH LOCATED
2019-07-16HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FR
2019-06-21HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FR
2019-06-21HPD class B: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SPRINKLER CAP SEALED WITH PAINT AT CEILING IN THE BATHROOM LOCATED AT APT
2019-06-21HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ADDITIONAL DEVICE REQUIRED IN THE ENTIRE APARTMENT LOCATED AT AP
2019-06-21HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR , ADDITIONAL DEVICE REQUIRED IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1
2019-06-14HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF GARBAGE CANS STORED AT PUBLIC HALL, 1st STORY
2019-06-14HPD class B: § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER AT BAL
2019-06-14HPD class B: § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS BUILDI
2019-06-12311: Consumer Complaint — Retail Store
2019-06-05Rodent inspection: Passed
2019-05-21HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM
2019-05-21HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FR
2019-05-21HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE DOOR SADDLE IN THE ENTRANCE LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT F
2019-05-21HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FR
2019-05-21HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK THROUGHOUT CEILING IN THE BATHROOM LOCATED AT APT 3B,
2019-05-21HPD class A: § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY
2019-05-21HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE 5th ROOM FROM
2019-05-21HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM
2019-05-21HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 4A, 4th STORY, 1st APA
2019-05-21HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED
2019-05-21HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL IN THE BATHROOM LOCATED AT APT 4
2019-05-21HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE FOYER LOCATED AT APT 4A,
2019-05-21HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM
2019-05-21HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE BATHROOM LOCA
2019-05-21HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT VESTUBLE DOOR AT PUBLIC HALL, 1st STORY
2019-05-21HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT
2019-05-21HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 2nd ROOM FROM NORTH AT
2019-05-21HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT
2019-05-21HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 2nd ROOM FROM NORTH AT
2019-05-21HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED
2019-05-21HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 2B, 2nd STOR
2019-05-21HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH LO
2019-05-21HPD class B: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRICAL OUTLET AT EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2C, 2nd STORY,
2019-05-21HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT AP
2019-05-21HPD class B: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ELECTRICAL OUTLET AT EAST WALL IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM
2019-05-21HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE KITCHEN LOCATED AT APT
2019-05-21HPD class B: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE DOOR KNOB AT ENTRANCE IN THE 6th ROOM FROM NORTH LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FR
2019-05-21HPD class C: HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FR
2019-05-21HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK THROUGHOUT CEILING IN THE FOYER LOCATED AT APT 4A, 4t
2019-05-21HPD class B: § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF TRASH CANS AND HOUSEHOLD ITEMS AT PUBLIC HALL, 1st STORY
2019-02-02HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER GLASS PANE AT BUILDING ENTRANCE AT PUBLIC HALL, 1st STORY
2019-02-02HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH AT 2ND WINDOW FROM WEST AT NORTH IN THE 1st ROOM FRO
2019-02-02HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AND ASSEMBLY AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
2019-02-02HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 5C, 5th S
2019-02-02HPD class C: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM NORTH
2019-02-02HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE KITCHEN LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM NOR
2019-01-25Rodent inspection: Passed
2019-01-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE BATHROOM L
2019-01-25HPD class C: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
2019-01-25HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 2nd ROOM FROM NORTH LO
2019-01-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE PRIVATE HALLW
2019-01-25HPD class C: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
2019-01-25HPD class C: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
2019-01-25HPD class C: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
2019-01-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE 1st ROOM FROM
2019-01-25HPD class A: § 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
2019-01-25HPD class C: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
2019-01-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE BATHROOM LOCA
2019-01-25HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 5A, 5th STORY, 1st APARTM
2019-01-25HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT SWITCH COVER AT SOUTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 5A, 5th STORY, 1s
2019-01-25HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WASH BASIN CABINET IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FR
2019-01-25HPD class C: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
2019-01-25HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK THROUGHOUT CEILING IN THE PRIVATE HALLWAY LOCATED AT
2019-01-25HPD class B: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HANGING SMOKE DETECTOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 4B, 4th STORY, 1st APAR
2019-01-25HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE PRIVATE HALLW
2018-11-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-11-16Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-10-09Rodent inspection: Failed for Other Reason
2018-10-09HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ..DEFECTIVE LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAS
2018-10-09HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ...DEFECTIVE LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
2018-10-09HPD class A: § 27-2005 ADM CODE REFIT DOOR AT LOWER CABINET BENEATH WASH BASIN IN THE BATHROOM LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM NORTH AT
2018-10-09HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ...BROKEN MIRROR AT THE CABINET ABOVE THE WASH BASIN IN THE BATHROOM LOCATED AT
2018-10-09HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH IN THE 1st ROOM FROM NORTH AT WEST LOCATED A
2018-10-09HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH IN THE 6th ROOM FROM NORTH LOCATED AT APT 5B
2018-07-12HPD class A: § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES
2018-06-28311: HEAT/HOT WATER — ENTIRE BUILDING
2018-06-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-06-22Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-06-19HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWEER SASH GLASS PANE AT WINDOW IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2A, 2
2018-06-19HPD class A: § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... THREE SQUARE FEET AT CEILING IN THE BATHROOM LOCATED
2018-06-19HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH A
2018-06-19HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT
2018-06-19HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
2018-06-16311: WATER LEAK — HEAVY FLOW
2018-06-16311: PAINT/PLASTER — CEILING
2018-06-16311: UNSANITARY CONDITION — MOLD
2018-06-16Tenant complaint: WATER LEAK — HEAVY FLOW
2018-05-16HPD class B: § 27-2017.3 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 2SQ FT AT CEILIG IN THE BATHROOM LOCATED AT APT 2A, 2nd
2018-05-16HPD class C: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STO
2018-05-16HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUT AT NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2A, 2nd ST
2018-05-15311: UNSANITARY CONDITION — MOLD
2018-05-15311: PAINT/PLASTER — CEILING
2018-05-15311: ELECTRIC — WIRING
2018-05-15311: WATER LEAK — HEAVY FLOW
2018-05-15Tenant complaint: ELECTRIC — WIRING
2018-05-15Tenant complaint: WATER LEAK — HEAVY FLOW
2018-05-06HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STO
2018-05-06HPD class B: § 27-2017.3 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL, 1st WINDOW FRAME FROM NORTH AT EAST WALL I
2018-05-06HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE KITCHEN , THE BAT
2018-04-26311: UNSANITARY CONDITION — MOLD
2018-04-26311: WATER LEAK — HEAVY FLOW
2018-04-26Tenant complaint: WATER LEAK — HEAVY FLOW
2018-03-22City emergency repair (HWO): at cellar, at door leading to sidewalk bilco door, remove (4) slide bolts, and leave accessible in case of fire. remove $65
2018-03-22HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BUILDING ENTRANCE DOOR LOCK AT FRONT AREAWAY, 1st STORY
2018-03-20311: General Construction/Plumbing — Failure To Maintain
2018-03-20DOB complaint, category ?
2018-03-20DOB complaint, category ?
2018-03-17ECB CLASS - 1 violation: UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.NOTED:AT CELLAR,NEW PLUMBING INSTALLED FOR 2PC(TOILET AND WASHBI
2018-03-14Rodent inspection: Failed for Rat Activity and Other Reason
2018-03-14311: HEAT/HOT WATER — ENTIRE BUILDING
2018-03-14311: HEAT/HOT WATER — ENTIRE BUILDING
2018-03-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-03-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-03-14HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 2nd ROOM FROM NORTH AT
2018-03-14HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 1st ROOM F
2018-03-14HPD class A: § 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
2018-03-14HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING ALL WALLS IN THE 2nd ROOM FROM EAST AT NORT
2018-03-14HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
2018-03-14HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT ROOM DOOR LEADING TO FIRE ESCAPE IN THE 3rd
2018-03-14HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
2018-03-14HPD class B: § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL STORE MERCHANDISE AT BASEMENT
2018-03-14HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 1st ROOM FROM EAST AT
2018-03-14HPD class A: § 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
2018-03-14HPD class B: § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK THROUGHOUT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 5A, 5th STORY, 1st
2018-03-14HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE FOYER LOCATED AT APT 5
2018-03-14HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT BUILDING ENTRANCE AT PUBLIC HALL, 1st STORY
2018-03-14HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE KITCHEN LOCATED AT APT
2018-03-14HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER WINDOW SASH GLASS PANE IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 4
2018-03-14HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 1st ROOM FROM EAST AT
2018-03-14HPD class C: § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING SLIDE BOLT AT DOOR AT BASEMENT
2018-03-14HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT AP
2018-03-14HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH AT
2018-03-14HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF STORAGE SHELFS BLOCKING EGRESS TO ROOM WITH FIRE ESCAPE IN THE PRIVATE HAL
2018-03-14ECB CLASS - 1 violation: FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.OBSERVED ON 03/14/2018 @ABOVE ADDRESS GAS LEAK FOUND ON WATER (HEATER) IN CELLAR$1,250
2018-03-14ECB CLASS - 2 violation: UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE. OBSERVED THE FOLLOWING $400
2018-03-14ECB CLASS - 2 violation: FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:AT CELLAR LEVEL,EXIT DOOR LEANING TO EXIT PASSAGEWAY AT EAST SECTION OF CELL$312
2018-03-11311: HEAT/HOT WATER — ENTIRE BUILDING
2018-03-11Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2018-03-06Rodent inspection: Passed
2018-02-08ECB CLASS - 1 violation: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35289919N ISSUED ON 08/22/17 AND TO FILE A CERTIFI
2018-01-02Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017
2017-12-28ECB CLASS - 1 violation: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35289919N ISSUED ON 08/22/17 AND TO FILE A CERTIFIC
2017-12-13HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
2017-12-13HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT BUILDING ENTRANCE DOOR , 1st STORY
2017-12-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 5th ROOM FROM NORTH LOCATED AT APT 4B, 4t
2017-12-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BASE CABINET AT WASH/BASIN IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 2nd APAR
2017-12-13HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR IN THE 5th ROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM
2017-12-06HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STO
2017-11-27Rodent inspection: Failed for Other Reason
2017-11-15DOB violation AEUHAZ1: FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2017-11-14Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-11-12311: HEAT/HOT WATER — ENTIRE BUILDING
2017-11-12Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-11-08ECB CLASS - 1 violation: FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35289919N ISSUED ON 08/22/17 & TO FILE A C OF C PURSUANT TO 28-201.1
2017-09-28ECB CLASS - 2 violation: FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUM/VIO#35289873R ISSUED ON 08/22/17 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1$400
2017-09-28ECB CLASS - 1 violation: FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35289919N ISSUED ON 08/22/17 & TO FILE A C OF C PURSUANT TO 28-201.1
2017-09-28ECB CLASS - 2 violation: FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUM/VIO#35289920K ISSUED ON 08/22/17 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1$400
2017-08-28311: General Construction/Plumbing — Failure To Maintain
2017-08-28DOB complaint, category ?
2017-08-23ECB CLASS - 1 violation: FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED;AT CELLAR LEVEL,OBSERVED EMERGENCY EXIT DOORS OBSTRUCTED W/BOXES OF SUPPLIES
2017-08-22Rodent inspection: Failed for Other Reason
2017-08-22HPD class C: § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING LOCKABLE SLIDE BOLT AT DOOR LEADING TO BASEMENT AT BASEMENT
2017-08-22HPD class B: § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF STORE MERCHANDISE OBSTRUCTING EGRESS AT BASEMENT
2017-08-22HPD class C: § 27-2005 ADM CODE PROVIDE DOOR HANDLE AT DOOR EXTERIOR AT BULKHEAD ROOF
2017-08-22HPD class C: § 12 M/D LAW DISCONTINUE THE STORAGE OF COMBUSTIBLE MATERIAL OF STORE MERCHANDISE APPROX 100 CU YDS. AT BASEMENT
2017-08-22HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WEST WALL IN THE PRIVATE HALLW
2017-08-22HPD class B: § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF GARBAGE BINS AT PUBLIC HALL, 1st STORY
2017-08-22HPD class B: § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AN
2017-08-22HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK VESTIBULE DOOR AT PUBLIC HALL, 1st STORY
2017-08-22HPD class B: § 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS WATER CLOSET AT BASE
2017-08-22ECB CLASS - 1 violation: FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:AT CELLAR LEVEL,OBSERVED EMERGENCY EXIT DOORS OBSTRUCTED W/BOXES OF SUPPLIES$250
2017-08-22ECB CLASS - 1 violation: FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. OBSERVED MANNER. OBSERVED IN CELLAR WATER LEAKING FROM DRAIN VALVE ON BOILER $250
2017-08-22ECB CLASS - 1 violation: UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.NOTED:AT CELLAR LEVEL,NEW PLUMBING,INSTALLED FOR 2 PC(WASH BASIN
2017-08-22ECB CLASS - 1 violation: WOEK W/O PERMIT.NOTED;AT CELLAR LEVEL,PLUMBING LINES INSTALLED FOR 2PC(TOILET & WASH BASIN)BATHRM.FULL HT PARTITIONS ERECTED TO EN
2017-08-22ECB CLASS - 2 violation: FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER;USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.87;27-371(I)NOTED;AT CELLAR$250
2017-08-01HPD class A: § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND
2017-08-01HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM
2017-08-01HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK VESTIBULE DOOR AT PUBLIC HALL, 1st STORY
2017-08-01HPD class A: § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES
2017-05-19Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2017-05-19HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM , LOCKED BASEMENT DOOR.
2017-05-19HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST
2017-05-19HPD class C: § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT
2017-05-19HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORT
2017-05-18Rodent inspection: Passed
2017-05-17311: HEAT/HOT WATER — ENTIRE BUILDING
2017-05-17Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-05-11City emergency repair (HWO): apt.2a: apt. entrance door: replace defective lock with new mortise lock , ''remove all work related debris''. at the ti
2017-05-04HPD class A: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD DOOR FRAME JAMB AT NORTH IN THE 5th ROOM FROM NORTH LOCATED AT APT 2B, 2nd S
2017-05-01Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-05-01HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORT
2017-05-01HPD class C: § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORT
2017-04-30311: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-30Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-29311: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-29Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-28311: HEAT/HOT WATER — APARTMENT ONLY
2017-04-28311: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-28Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-28Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2017-04-24HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AT STREET ENTRANCE DOOR TO BUILDING.
2017-04-21311: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-21Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-19311: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-19311: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-19Tenant complaint: HEAT/HOT WATER — ENTIRE BUILDING
2017-04-03HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 4A,
2017-03-31HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE 2n
2017-03-31HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK IN THE ENTRANCE LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NOR
2017-03-31HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
2017-03-31HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ... NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT
2017-03-31HPD class A: § 27-2005 ADM CODE REFIT DOOR UNHINGED AT NORTH DOOR FRAME IN THE 5th ROOM FROM NORTH LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM EAST
2017-03-31HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE KITCHEN LOCATED A
2017-03-27Rodent inspection: Passed
2017-03-27HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
2017-03-27HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT
2017-03-27HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
2017-03-27HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT
2017-03-27HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT BUILDING ENTRANCE DOOR , 1st STORY
2017-03-27HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM EAST AT
2017-03-27HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE BATHROOM LOCATED AT A
2017-03-27HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED
2017-03-27HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE 5th ROOM FROM NORTH LO
2017-03-27HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE BATHROOM L
2017-03-27HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 3A,
2017-03-27HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM EAST
2017-03-27HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE GROUND FAULT ELECTRICAL OUTLET AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3B, 3r
2017-03-27HPD class B: § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4C, 4th STO
2017-03-27HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM EAST
2017-03-27HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM NORTH AT EAST
2017-03-27HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR TO ROOM , LEADING TO FIRE ESCAPE IN THE 1st ROOM
2017-03-27HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
2017-03-27HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd
2017-03-27HPD class C: § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK
2017-03-27HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHROOM LOCATED AT APT 4C, 4th
2017-03-27HPD class C: § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK
2017-03-27HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT
2017-03-27HPD class C: § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK
2017-03-27HPD class C: § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK
2017-03-27HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE KITCHEN LOCATED AT APT 2B, 2n
2017-01-25HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT BUILDING FRONT ENTRANCE DOOR , 1st STORY
2017-01-17Tenant complaint: ELECTRIC — NO LIGHTING
2017-01-16311: ELECTRIC — POWER OUTAGE
2017-01-16Tenant complaint: ELECTRIC — POWER OUTAGE
2016
2016-12-13Rodent inspection: Passed
2016-12-13HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK TO THE ENTRANCE DOOR OF THE BUILDING AT LOBBY, 1st STORY
2016-12-01311: HEAT/HOT WATER — APARTMENT ONLY
2016-12-01Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-11-03HPD class B: § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF GARBAGE/ RECYCLE AT PUBLIC HALL , 1st STORY
2016-11-03HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT , SOUTH WALL AT PUBLIC HALL, 1st STORY
2016-11-03HPD class B: § 27-2050 ADM CODE PROVIDE A PIECE OF GARDEN HOSE 10 FEET IN LENGTH WITH FEMALE COUPLING AND A 10 QUART PAIL ON PREMISES TO TEST SPRINKLER S
2016-11-03HPD class B: § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF WINDOW S
2016-11-03HPD class B: § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. RESTORE EGRESS BY REMOVING LOCKING DEVICE AND ARRANGE TO OPEN READILY THE GATE IN FENCE AT L
2016-11-03HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AT BUILDING ENTRANCE DOOR , 1st STORY
2016-10-24HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PANIC BAR TO THE ROOF DOOR
2016-10-24HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK TO THE ENTRANCE DOOR OF THE BUILDING AT LOBBY, 1st STORY
2016-09-20HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST A
2016-09-19Rodent inspection: Failed for Other Reason
2016-09-19HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY,
2016-09-19HPD class B: § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF GARBAGE
2016-09-19HPD class B: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM NORTH L
2016-09-19HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY,
2016-09-19HPD class B: § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF GARBAGE AND RECYCLE CANS AT PUBLIC HALL, 1st STORY
2016-09-19HPD class C: § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK
2016-09-19HPD class B: § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM EAST AT
2016-09-19HPD class B: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT
2016-09-19HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CHAIN AND LOCK AT LOT LINE OBSTRUCTING EGRESS AT REAR YARD
2016-09-19HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL IN THE BATHROOM LOCATED AT APT 4B, 4t
2016-09-15311: Broken Muni Meter — Coin or Card Did Not Register
2016-09-04HPD class B: § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES , (WINDOW SCREENS) AT
2016-09-01Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-08-24Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-08-19Rodent inspection: Passed
2016-07-25City emergency repair (OMO): ( apt # 5b ) properly replace with new the defective counter balance of the lower window sash (window on east wall ) . r$194
2016-07-05City emergency repair (OMO): as per the requirement contract with h.p.d and h.p.d/doh guidelines, install/repair window guards: at public parts. dhs $45
2016-06-16City emergency repair (HWO): p/hall 1sty; remove rubbish from hallway approx 2 cyds., clean and disinfect area, ''remove all work related debris''.
2016-06-16City emergency repair (OMO): public parts: at roof. at rear parapet wall at gooseneck ladder, replace with new the missing metal coping approx 11lf t$900
2016-06-12Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-05-31HPD class C: § 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE GARBAGE AT ALL STORIES AT PUB
2016-05-31HPD class B: § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT ROOF BULKHEAD
2016-05-31HPD class C: § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SELF LOCKING PANIC BAR INSTALLED ON BULKHEAD DOOR TO ROOF
2016-05-31HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE METAL CAPING OF PARAPET WALL AT GOOSENECK LADDER AT ROOF REAR
2016-05-31HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CRACKED GLASS AT ENTRANCE DOOR AT PUBLIC HALL, 1st STORY
2016-05-31HPD class A: § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKIN
2016-05-31HPD class C: § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECI
2016-05-31HPD class B: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MORTISE LOCK LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
2016-05-31HPD class C: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WOODEN CABINET AT WEST WALL (IN DANGER OF FALLING) IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY,
2016-05-31HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS, BOTTOM SASH WINDOW IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2C,
2016-05-31HPD class C: § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CI
2016-05-31HPD class B: § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN DRAIN OF BATHTUB IN THE BATHROOM LOCATED AT APT 5B, 5th STORY, 2nd APAR
2016-05-31HPD class B: § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT
2016-05-31HPD class A: § 27-2005 ADM CODE REFIT ENTRANCE DOOR LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
2016-05-31HPD class B: § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS , LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
2016-05-31HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
2016-05-31HPD class B: § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 5B, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
2016-05-31HPD class C: § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE COUNTER BALANCE OF LOWER SASH IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT
2016-05-31HPD class C: § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE GOOSENECK AT ROOF REAR FIRE ESCAPE
2016-05-31HPD class C: § 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE GARBAGE AT EAST AND WEST AIR
2016-05-18311: Broken Muni Meter — Coin or Card Did Not Register
2016-03-18311: Broken Muni Meter — Coin or Card Did Not Register
2016-02-25Agreement $38,000,000 — from 148 WEST 124TH ST. LLC; 416 E. 138TH ST. LLC; 2153 5TH AVENUE, LLC; 27 EAST 131 ST. LLC; 4 to CUSTOMERS BANK$38,000,000
2016-02-25AL&R $38,000,000 — from 475 WEST 145TH ST LLC; 416 E. 138TH ST. LLC; 819 EAST 178TH STREET, LLC; 2153 5TH AVENUE, to CUSTOMERS BANK$38,000,000
2016-02-25AL&R $38,000,000 — from 475 WEST 145TH ST LLC; 416 E. 138TH ST. LLC; 819 EAST 178TH STREET, LLC; 2153 5TH AVENUE, to CUSTOMERS BANK$38,000,000
2016-02-25Agreement $38,000,000 — from 148 WEST 124TH ST. LLC; 416 E. 138TH ST. LLC; 2153 5TH AVENUE, LLC; 27 EAST 131 ST. LLC; 4 to CUSTOMERS BANK$38,000,000
2016-02-25Mortgage $15,882,677 — from 819 EAST 178TH STREET, LLC; 27 EAST 131 ST. LLC; 492 EAST 138TH STREET, LLC; 148 WEST 124T to CUSTOMERS BANK$15,882,677
2016-02-25Mortgage $15,882,677 — from 819 EAST 178TH STREET, LLC; 27 EAST 131 ST. LLC; 492 EAST 138TH STREET, LLC; 148 WEST 124T to CUSTOMERS BANK$15,882,677
2016-02-15Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-02-10Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-02-03Rodent inspection: Passed
2016-01-22Tenant complaint: PLUMBING — WATER SUPPLY
2016-01-22Tenant complaint: PLUMBING — WATER SUPPLY
2016-01-22Tenant complaint: PLUMBING — WATER SUPPLY
2016-01-22Tenant complaint: HEAT/HOT WATER — APARTMENT ONLY
2016-01-22Tenant complaint: PLUMBING — WATER SUPPLY
2016-01-18HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAS
2016-01-18HPD class A: § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE ENTIRE APARTMENT LOCAT
2016-01-18HPD class B: § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WOOD WALL CABINETS IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM SOUTH AT WES
2016-01-18HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 2n
2016-01-18HPD class B: § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 2nd APARTMENT FROM EAS
2016-01-18HPD class C: § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT BUILDING ENTRANCE DOOR , 1st STORY
2016-01-18HPD class B: § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1s
2016-01-18HPD class A: § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND NORTH WALL IN THE FOYER LOCATE
2016-01-16311: Broken Muni Meter — No Receipt
2016-01-05TL&R — from FIRST REPUBLIC BANK to 108-110 EAST 116TH ST. LLC
2016-01-05Mortgage assigned — from FIRST REPUBLIC BANK to CUSTOMER BANK
2016-01-05Mortgage assigned — from FIRST REPUBLIC BANK to CUSTOMER BANK
2016-01-05TL&R — from FIRST REPUBLIC BANK to 108-110 EAST 116TH ST. LLC
2015
2015-10-29311: Broken Muni Meter — Out of Order
2015-10-19311: Broken Muni Meter — Out of Order
2015-09-25FDNY inspection (RISK)
2015-05-05Certificate of occupancy Final
2015-04-22CDEC — from THE 108 EAST 116 STREET CONDOMINIUM
2015-04-22MAPS — from THE 108 EAST 116 STREET CONDOMINIUM
2015-04-22MAPS — from THE 108 EAST 116 STREET CONDOMINIUM
2015-04-22CDEC — from THE 108 EAST 116 STREET CONDOMINIUM
2015-04-14Certificate of occupancy Temporary
2015-03-13Rodent inspection: Passed
2014
2014-11-26Permit PL — ISSUED
2014-11-20Permit EW — ISSUED
2014-11-20Permit EW — ISSUED
2014-10-23Job filed: SUBDIVISION OF IMPROVED PROPERTY INTO TWO CONDOMINIUMS. ONE TAX LOT (67) INTO TWO TAX LOTS (UNIT#1 COMMERCIAL - LOT 1101 , UNIT#2 RESIDENTIAL - LOT 11
2014-08-15Job filed: NEW OPENINGS ALONG LOT LINE WALL. RENOVATION OF COMMERCIAL SPACE. FINISH WALLS SHELVING, FINISH FLOORS, NEW LIGHTING. NEW HVAC REPLACE FIXTURES.$610,000
2014-06-18Permit AL — ISSUED
2014-06-05Certificate of occupancy Temporary
2014-03-06Certificate of occupancy Temporary
2014-02-24Permit PL — ISSUED
2013
2013-11-19Permit AL — ISSUED
2013-10-22Permit EW — ISSUED
2013-10-18Rodent inspection: Passed
2013-09-27HPD class B: § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNS
2013-09-23Permit AL — ISSUED
2013-08-20Permit EW — ISSUED
2013-08-08Job filed: RENOVATION OF COMMERCIAL SPACE. NEW CONCRETE SLAB AND METAL DECKING AT FIRST FLOOR. NEW CONCRETE SLAB AT CELLAR LEVEL.$30,000
2013-05-29HPD class I: § 27-2089 ADM CODE ABOVE PREMISES HAVE BEEN VACANT AND UNTENANTED EXCEPT FOR CARETAKER FOR 60 DAYS OR MORE, AND CANNOT BE REOCCUPIED UNTIL A
2013-02-15Permit PL — ISSUED
2012
2012-10-25Job filed: PIPE SCAFFOLDING FILED IN CONJUNCTION WITH ALT-1 APPLICATION
2012-10-02Permit EQ — ISSUED
2012-10-02Permit AL — ISSUED
2012-10-02Permit EQ — ISSUED
2012-06-20Job filed: NEW PARTITIONS, NEW KITCHENS AND BATHS,REPLACEMENT KITCHENS AND BATHS, REMOVAL OF MINOR PARTITONS.REPOINTING EXTERIOR WORK WHERE NECESSARY. REPAIR BRI$664,500
2012-05-09311: Construction Safety Enforcement — SST Tracking Complaint
2012-05-09DOB complaint, category ?
2012-05-09ECB CLASS - 2 violation: SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. NOTED: SIDEWALK SHED IS MISSING 5' EXTENSION AT EXP #2, LIGHTING FIXTURES UNDERNE$2,400
2012-05-09ECB CLASS - 2 violation: FAILURE TO PROVIDE/POST SIGN AT JOB SITE. NOTED: NO CONTRACTORS SIGN POSTED ON SIDEWALK SHED AT STREET FRONT, AS REQUIRED - REMED
2012-05-02Permit EQ — ISSUED
2012-05-02Permit EQ — ISSUED
2012-05-02Permit AL — ISSUED
2012-04-30Rodent inspection: Passed
2012-04-20Permit EQ — ISSUED
2012-04-20Job filed: PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED FILED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION
2012-04-04Job filed: ADDING FENCETO JOB
2012-04-04Job filed: ADDING FENCETO JOB
2012-03-16Job filed: INSTALLATION OF SPRINKLER SYSTEM IN ENTIRE BUILDING . SPRINKLER SEVICE AND BOOSTER PUMP INSTALLED AT 110 E 116 ST AND PROVIDED TO 108 E 116 ST UNDER
2012-02-16Permit EW — ISSUED
2012-02-16Permit EW — ISSUED
2012-02-06Job filed: A1$603,500
2011
2011-12-13DOB violation LBLVIO: VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
2011-10-07Permit PL — ISSUED
2011-10-06Permit EW — ISSUED
2011-10-06Permit EW — ISSUED
2011-10-05Job filed: NEW PARTITIONS, FIXTURE REPLACEMENTS,RELOCATE KITCHEN, REMOVAL OF MINOR PARTITIONS. HOT & COLD WATER GAS REPIPE THROUGHOUT BUILDING. INDIVIDUAL GA$204,000
2011-07-25DOB complaint, category ?
2011-07-18DOB complaint, category ?
2011-05-09Rodent inspection: Passed
2011-03-30HPD class B: § 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNS
2010
2010-04-21Rodent inspection: Passed
2009
2009-01-01DOB violation LL6291:
2008
2008-01-03DOB violation LL6291:
2007
2007-01-19DOB violation LL6291:
2006
2006-08-11DOB complaint, category ?
2003
2003-03-19DOB violation LL6291:
2001
2001-02-27DOB violation LL6291:
2000
2000-02-07DOB violation LL6291:
1999
1999-03-16DOB violation LL6291:
1995
1995-08-21DOB violation B:
1993
1993-03-18DOB violation LL6291:
1975
1975-10-14HPD class I: D26-35.01 ADM CODE ABOVE PREMISES HAVE BEEN VACANT AND UNTENANTED EXCEPT FOR CARETAKER FOR 60 DAYS OR MORE, AND CANNOT BE REOCCUPIED UNTIL A